32
Digital multimeter
GB
4.2.6 Beeper continuity
Measuring range: 600 Ohm
Resolution: 0.1 Ohm
Description:
When the built-in beeper sounds and the accompanying green indicator is on, the measured Open-circuit
voltage resistance must not be over approx. 1 V 30 Ohm. The red indicator will be on when the resistance
is between 40 and 60 Ohm.
Testing conditions:
Open-circuit voltage: approximately 1 V
Overload protection: 600 V AC/DC
4.2.7 hFE (transistor)
hFE measuring range
The approximate hFE value shown on the display unit (0-2000)
Testing conditions
Base current: approximately 10 μA Vce approximately 2.8 V
4.2.8 Capacitor
Measuring range
Resolution
Accuracy
6 nF
0.001 nF
+/- (4.0% r 30 digits)
60 nF
0.01 nF
600 nF
0.1 nF
6 μF
1 nF
60 μF
10 nF
+/- (4.0% r 3 digits)
600 μF
100 nF
6 mF
1 uF
100 mF
0.01 mF
+/- (5% r 3 digits)
Overload protection: 600 V AC/DC
4.2.9 DC current
Measuring range
Resolution
Accuracy
60 μA
0.01 μA
+/- (0.8% r 3 digits)
60 mA
0.01 mA
600 mA
0.1 mA
+/- (1.2% r 3 digits)
20 A
10 mA
Overload protection: protective tube for mA measuring range (FF630 mA / 250 V); protective tube for 20 A measuring
range (FF 20 A / 250 V).
Maximum input voltage: mA position: 600 mA AC/DC (valid value); 20 A position: 20 A AC/DC (valid value)
If the measured current is over 5 A, the duration of the continuous measurement should not exceed 10 seconds.