44
Horizontal and built-under fresh-water storage
tanks 120 – 500
7.10
Fresh-water, Combined and Buffer Storage Tanks
GB
Horizontal and built-under
fresh-water storage tanks without,
with one (-1) or with two (-2)
120 / 120-1 /
150 / 150-1 /
200 / 200-1 /
300 / 300-1 /
400 / 400-1 /
500 / 500-1 /
additional heat exchangers
120-2
150-2
200-2
300-2
400-2
500-2
Real volume according
to EN 12897
[l]
117 / 116 / 115
157 / 156 / 155
206 / 205 / 204
301 / 300 / 298
455 / 454 / 452
498 / 496 / 494
Fire protection class of insulation
according to DIN 4102-1
[-]
B2
B2
B2
B2
B2
B2
Total height* including insulation
[mm]
700
700
700
700
850
850
Width
[mm]
610
610
610
610
760
760
Length
[mm]
785
995
1,260
1,750
1,600
1,730
Weight
[kg]
55 / 60 / 65
65 / 72/ 79
79 / 87 / 96
103 / 111 / 120
123 / 136 / 150
141 / 154 / 167
Energy efficiency class according
to EU regulation no. 812/2013
[-]
A+
A+
A+
A+
A+
A+
Heat retaining loss according to EN 12897
[W]
26
29
31
36
41
43
Output capacity 45°C
(storage tanks 65°C,
cold water 10°C, no reheating)
[l]
70
85
115
175
230
290
Performance factor NL
following DIN 4708
[-]
0.8
1
1.2
1.6
2
3
Storage tank pmax / tmax
[bar] / [°C]
3 / 95
3 / 95
3 / 95
3 / 95
3 / 95
3 / 95
DHW heat exchanger
surface / volume
[m²] / [l]
1.52 / 6.92
2.1 / 9.6
2.5 / 11
2.5 / 11
5.1 / 23
5.1 / 23
DHW heat exchanger
pmax / tmax
[bar] / [°C]
6 / 95
6 / 95
6 / 95
6 / 95
6 / 95
6 / 95
Additional heat exchanger**
bottom surface / volume
[m²] / [l]
1 / 4.69
1.4 / 6.2
1.7 / 8
1.7 / 8
3 / 14
3 / 14
Additional heat exchanger**
top surface / volume
[m²] / [l]
1 / 4.55
1.4 / 6.1
1.7 / 8
1.7 / 8
3 / 14
3 / 14
Additional heat exchanger**
pmax / tmax
[bar] / [°C]
6 / 95
6 / 95
6 / 95
6 / 95
6 / 95
6 / 95
Return additional heat
exchanger bottom** (Rp 1¼")
A [mm]
Return heat generator (R 1")
B [mm]
Cold water connection (Rp 1¼")
C [mm]
Flow additional heat exchanger**
bottom (Rp 1¼")
D [mm]
Freely available (R 1")
E [mm]
Return additional heat
exchanger** top (Rp 1¼")
F [mm]
Freely available (R 1")
G [mm]
Sensor sleeve*** (Ø 6 mm)
H [mm]
Flow additional heat exchanger**
topn (Rp 1¼")
I [mm]
Flow heat generator (R 1")
J [mm]
Hot water connection (Rp 1¼")
K [mm]
Sensor cable feed-through
(45x18 mm)
L [mm]
Thermometer (clip)
M [mm]
Heating element (Rp 1½")
N [mm]
cable feed-through heating
element (Ø 26 mm)
O [mm]
* feet adjustable by ±13mm
** if there is one
*** Caution: Install the temperature sensors before mounting the steel jacket.
Use the sensor cable feed-through (L) for guiding the temperature sensors.
A
B
C
D
E
F
G
K
I
L
M
J
N
O
A
B
C
D
E
F
G
I
J
K
M
N
H
H
Содержание 150
Страница 24: ...F r Ihre Notizen...
Страница 25: ...F r Ihre Notizen...
Страница 48: ...Notes...
Страница 49: ...Notes...
Страница 72: ...Pour vos notes...
Страница 73: ...Pour vos notes...
Страница 96: ...Voor uw aantekeningen...
Страница 97: ...Voor uw aantekeningen...
Страница 98: ...F r Ihre Notizen Notes Pour vos notes Voor uw aantekeningen...
Страница 99: ...F r Ihre Notizen Notes Pour vos notes Voor uw aantekeningen...