22
Direct Vent Termination Kit
When installed as a Direct Vent boiler the combustion air-inlet must also be piped directly to the outdoors using
the methods described in this section and in accordance with the CSA B139 (Canada) or NFPA 31 (USA) and
local code requirements.
Venting Options - Due to potential moisture loading (build-up) along the exterior wall,
sidewall venting may not be the preferred venting option.
The majority of the balance flue components required for Direct Vent installations are included with the
Burner Kit. Remaining components must be ordered separately. Refer to the components listed in Table
7-2 and illustrated in Figure 7-2.
Table 7-2 Direct Vent Components
Item
Part #
Description
Included with Direct Vent Burner Kit
1
81764
5” to 3” Ported Adapter
2
81098
3” Insulated Flex to Pipe Adapter
3
81138
3” Flex, 10’ long
3
4
81625
Hose Clamps, 3” (2)
Direct Vent Terminal
1
5
81522-1 Direct Vent Terminal, 8”
Insulated Flex
1,3
81109
5’ Insulated Flex
81097
10’ Insulated Flex
81110
15’ Insulated Flex
6
81111
20’ Insulated Flex
Optional Components
2
-
81522-2 Extended Direct Vent Terminal,
20”
-
81453
Silicone, High Temp., 302 (83ml)
-
81847
3” Direct Vent 90
o
Elbow
-
81633
Adapter3” x 20’ Flex Aluminum
-
83026
5” to 3” 90
o
Elbow Ported
Notes:
1
Required for Direct Vent installation but not included with boiler package; therefore, must be ordered separately.
2
Optional components available from NTI. Must be ordered separately.
3
The vent and air intake maximum length is 20’ (6m).
Components required for Direct Vent installation:
Items 1-4 included with the boiler’s DV Burner Kit.
Items 5-6 must be ordered separately.
6
1
3
2
5
4
4
Figure 7-
2