Odyssey
│
Installation and Operation Instructions
CT80-250
2
Read Before Proceeding
If you do not follow these instructions exactly, a fire may result causing property
damage, serious injury or death.
FOR YOUR SAFETY, READ BEFORE OPERATING
_
BEFORE OPERATING:
A.
Do not start burner unless the smoke hood, clean out door, HydroStat 3250, flue breeching, and burner
door (if applicable) are secured in place and the boiler is filled with water.
B.
Do not attempt to starter burner when excess oil has accumulated in combustion chamber, when unit is
full of vapour, or when combustion chamber is very hot.
C.
Do not use gasoline, crankcase drainings, or any oil containing gasoline.
D.
Never burn garbage or paper in the unit and never leave combustible material around it.
E.
Always keep the oil supply valve shut off if the burner is shut down for an extended period of time.
F.
Do not tamper with the unit or controls - call your service personnel for service and maintenance.
G.
Do not use this boiler if any part has been under water. Immediately call a qualified service technician to
inspect the
boiler and to replace any part of the
control system and any oil control which has been
under water.
OPERATING INSTRUCTIONS
_
1.
STOP! Read the safety information above very carefully.
2.
Initial start-up and start-ups after periods of extended/seasonal shutdown must be performed by a
qualified service technician.
3.
Check the boiler area for proper clearances.
4.
Turn the thermostat(s) up.
5.
Turn the emergency power isolation switch on.
6.
If ignition does not occur, follow the instructions “To Turn Off Oil Boiler” and call a qualified service
technician.
TO TURN OFF OIL BOILER
_
1.
STOP! Read the safety information above very carefully.
2.
Turn off emergency power isolation switch. Should be mounted on the wall near entrance to boiler room.
Void Warranty - This boiler must have water in it whenever the burner is on or it will
damage the unit and void the warranty. Failure to follow these instructions may result in
serious injury or death.
Fuel Oil - Use only No. 2 fuel oil for boiler models listed in this manual. Failure to follow
these instructions may result in severe personal injury, property damage, or death.
Low Water Cut Off (LWCO) - To take advantage of the HydroStat’s LWCO feature, the
Odyssey is equipped with a special immersion well call the Electro-well™. Failure to use
the Electro-well™ provided with the boiler will over-ride the LWCO feature and allow the boiler to operate
during low water conditions which may result in over heating, fire, serious injury, or death.
Oil Supply Valve - Always keep the oil supply valve shut off if the burner is shut down
for an extended period of time.