OPTIC REPLACEMENT INSTRUCTIONS
CAUTION: DISCONNECT the unit from an electrical power source before
performing any maintenance or cleaning on the unit.
Step 1 –
Turn “PROCESSOR” switch to the “OFF” position
Step 2 –
Unplug power cord from the electrical receptacle
Step 3 –
Using the supplied key, unlock and remove both end panels
Step 4 –
Remove optic following these instructions:
CAUTION: Use clean powder free latex gloves and eye protection when
handling the optics in this unit.
•
With a firm grip on the upper porcelain end of the optic, use your other hand to
grip the optic connector.
•
Gently ‘wiggle’ connector while pulling from the optic base.
•
Gently pull optic from three lamp supports (Do not put any pressure on the side
of the optic without support).
Caution: Optics contain Mercury. Dispose of optics in accordance with
local regulations. To find out more about local regulations, please visit
www.lamprecycle.org.
Step 5 –
Install new optic following these instructions:
•
Remove new optic from packaging and gently insert into the three optic clips.
•
With a firm grip on the upper porcelain end of the optic, use your other hand to
grip the optic connector.
•
Gently connect the optic connector to the optic.
•
Note: Optic connector is keyed with the optic base and will connect in one
direction only
•
Ensure optic connector and optic base are firmly pressed together.
Step 6 –
Re-install end panels
Step 7 –
Plug power cord back into the electrical receptacle
Step 8 –
Test unit for proper operation