background image

PLEASE READ AND SAVE 

THESE IMPORTANT SAFETY  

INSTRUCTIONS 

IMPORTANT SAFEGUARDS

 

When  using  electrical  equipment,  basic 

safety  precautions  should  always  be 

followed  to  reduce  the  risk  of  fire,  electric 

shock, and injury to persons, including the 

following: 
•  Read  all  instructions  before  using  this 

Hydroxyl Generator. 

•  To  avoid  fire  or  shock  hazard,  plug  the 

equipment  directly  into  a  grounded  AC 

electrical outlet. 

• If the generator is covered by a bag when 

shipped: remove plastic bag before use. 

• Keep the cord out of heavy traffic areas. 

To  avoid  fire  hazard,  NEVER  put  the  cord 

under  rugs,  near  heat  registers,  radiators, 

stoves, or heaters. 

• To protect against electrical hazards, DO 

NOT immerse in water or other liquids. DO 

NOT use near water. 

•  DO  NOT  leave  the  generator  in  use 

unattended  around  those  requiring  close 

supervision. 

•  WARNING! Always  unplug  the  generator 

before moving it, cleaning, or whenever the 

generator is not in use. Be sure to pull by the 

plug and not the cord. 

• NEVER drop or insert any object into any 

openings. 

•  DO  NOT  operate  any  generator  with  a 

damaged cord or plug, if motor fan fails to 

rotate, after the generator malfunctions, or 

if  it  has  been  dropped  or  damaged  in  any 

manner. Return generator to manufacturer 

or authorized repair facility for examination, 

electrical or mechanical adjustment, or repair. 

•  Use  generator  only  for  intended  use  as 

described  in  this  manual.  Any  other  use 

not  recommended  by  the  manufacturer 

may  cause  fire,  electric  shock,  or  injury 

to  persons.  The  use  of  attachments  not 

recommended may cause hazards. 

• INDOOR USE ONLY!

• NEVER block the air openings, grills/outlets 

or place on a soft surface such as a bed or 

sofa, as this could cause the unit to tip over, 

blocking the Air Intake Opening/Grill. 

• Keep unit away from heated surfaces and 

open flames. 

•  CAUTION:    For  General  Ventilating  Use 

Only.  Do Not Use to Exhaust Hazardous or 

Explosive Materials and Vapors.

•  DO  NOT  attempt  to  repair  or  adjust  any 

electrical  or  mechanical  functions  on  this 

unit.  Doing  so  will  void  your  warranty. 

The  inside  of  the  unit  contains  no  user 

serviceable  parts.  All  servicing  should  be 

performed by qualified personnel only. 

•  WARNING!  To  reduce  the  risk  of  fire  or 

electric shock, DO NOT use this generator 

with any  solid-state speed control device. 

• DO NOT place anything on top of generator. 

• DO NOT plug the cord in with wet hands: 

electric shock could result. 

•  NEVER  use  detergents,  gasoline,  glass 

cleaner,  furniture  polish,  paint  thinner  or 

other household solvents to clean any part 

of the generator. 

• DO NOT, under any circumstances, cut or 

remove the third (Ground) prong from power 

cord.  For  personal  safety,  this  generator 

must be properly grounded. 

WARNING!

Use this Hydroxyl Generator only for its intended 

purpose as described in this Owner’s Manual. 

SAFETY INFORMATION

Содержание BOSS XL3

Страница 1: ......

Страница 2: ...1 Contents List 2 Odorox Boss XL3 Unit Operational Guidelines 3 Operating The Odorox Boss XL3 4 Care Instructions 5 Optic Replacement Instructions 6 Troubleshooting Guide 7 Specifications And Warranty 8 TABLE OF CONTENTS ...

Страница 3: ...echanical adjustment or repair Use generator only for intended use as described in this manual Any other use not recommended by the manufacturer may cause fire electric shock or injury to persons The use of attachments not recommended may cause hazards INDOOR USE ONLY NEVER block the air openings grills outlets or place on a soft surface such as a bed or sofa as this could cause the unit to tip ov...

Страница 4: ...dorox Boss XL3 Hydroxyl Generator is shipped with the following 1 Odorox Boss XL3 Hydroxyl Generator 2 Washable Filter 3 Set of Keys 4 Owners Manual 5 Warranty Card Note Air Mover Not Included CONTENTS LIST ...

Страница 5: ... chemical spills off gassing and any other odor problem you may encounter This unit allows you to decontaminate and deodorize while you dry because it joins directly to your existing air movers The Boss XL3 Unit is equipped with a selector switch for 2 or 3 Odorox hydroxyl generating optics and operates using very low Wattage For use in heavy odor concentrations the best performance will take plac...

Страница 6: ...can be powered on by turning the PROCESSOR switch to the LOW or HIGH position refer to Note above The green PROCESSOR ON LED will indicate when the Boss XL3 Unit has either two or three Odorox hydroxyl generating optics functioning POWER OFF The main power for the Boss XL3 Unit can be switched off by turning the PROCESSOR switch to the OFF position PROCESSOR The Boss XL3 Unit is equipped with thre...

Страница 7: ...eaned in the same manner as the exterior with the exception of the optics and optics housing OPTIC CLEANING Cleaning of the Odorox optics is recommended to maintain peak processing efficiency Fingerprints smudges dirt dust particles etc will interfere with the hydroxyl production and should be avoided Note Remove the optics from the optic chamber prior to cleaning to avoid any damage to the optics...

Страница 8: ...Gently pull optic from three lamp supports Do not put any pressure on the side of the optic without support Caution Optics contain Mercury Dispose of optics in accordance with local regulations To find out more about local regulations please visit www lamprecycle org Step 5 Install new optic following these instructions Remove new optic from packaging and gently insert into the three optic clips W...

Страница 9: ...to high speed Auxiliary air mover not rated for high enough static pressure low amperage unit Try the setup using an alternate auxiliary air mover Negative pressure tubing is kinked or not in the correct position to activate the pressure switch Ensure that the negative pressure tubing clear 1 4 inch is pulled through into the 7 inch discharge nozzle of the Boss XL3 Unit and that it is not kinked G...

Страница 10: ...YL GENERATING OPTIC BROWN XSA00EW02 3 OPTICS POWER CABLE XSA00EA01 3 BALLAST ASSEMBLY 120 VOLT N Am XSA00EA06 3 BALLAST ASSEMBLY 200 277 VOLT 50 60 Hz INTL EPC IL 021 1 LIGHT MODULE PROTECTED LED 110 120VAC GREEN N Am EPC IL 017 1 LIGHT MODULE PROTECTED LED 230 240VAC GREEN INTL EPC IL 148 1 LIGHT MODULE PROTECTED LED 110 120VAC RED N Am EPC IL 149 1 LIGHT MODULE PROTECTED LED 230 240VAC RED INTL ...

Страница 11: ...ibutor To find a distributor in your area please visit www Odorox com Odorox Hydroxyl Generators are proudly manufactured in the USA HGI Industries Inc 2055 High Ridge Road Boynton Beach FL 33426 Toll Free 877 735 3701 www hgiind com Copyright 2011 HGI Industries Incorporated Odorox and Boss XL3 are trademarks or registered trademarks of HGI Industries Incorporated Boynton Beach Florida USA ...

Отзывы: