MODULE OVERVIEW – LINE INPUT MODULES
22
4.1.3.
Installing the IN 4/IN 8 input module
Connecting the ribbon cable connector
► Please disconnect the unit from the mains before opening the cover
► Push in the ribbon cable connector until the locking pin clicks into the locking lever.
Legend
(1)
Ribbon cable
(3)
Ribbon cable connector
(2)
Locking pin
(4)
Locking lever
Removing the ribbon cable connector
1. Carefully bend the locking lever 2 mm to the back.
2. Grip the ribbon cable connector on the side and pull it upward. Do not pull out the
connector with the cable.