8
SUPPORT.OCTANEFITNESS.COM
SERVICE TRAINING
Diagnostics
Message
Center
Description
Matrix
Window 1
Window 2
Window 3
Window
4
MODEL VERSION
then
Media
Confi guration:
NO MEDIA, TV-
SHARP, TV-OCTANE,
or 900MHZ
Model and Software version and
confi guration information
Model #
Version
Number
VV.00
M LOWER BOARD
Model # and Software version of
Lower Board
Model # of
lower board
Processor
Version
Number
Processor
Version
Number
DISPLAY (ENTER)
Checks all LEDs. Use the numeric
keypad to change the speed of the
test (0 is slowest, 9 is fastest). When
you have verifi ed all LEDs, press
Pause Clear twice to exit this test.
LEDs light
LEDs light
LEDs light
LEDs light
LEDs light
KEYPAD (ENTER);
then
Name of Key pressed
Check all keys. Press each key
on the keypad and the stationary
handlebars and listen for the beep
to verify that each works properly.
Press Pause Clear twice to exit test.
TEST, PASS,
or FAIL
Count of
unique keys
pressed
BRAKE (ENTER)
then
BRAKE - TESTING
Brake motor test. Press Pause Clear
twice to exit the test.
Raw brake
position
Brake
current
LATERAL (ENTER)
Motor test. Press Pause Clear twice
to exit the test.
LEFT INIT
RIGHT INIT
SEEK
Left motor
raw value
Left motor
current
Right motor
raw value
Right
motor
current
PORTS (ENTER)
CSAFE Ports; for factory testing only.
(Requires a special cable.)
TEST, PASS,
or FAIL
BATTERY VOLTAGE
Displays the current charge level
of the battery. Should be 21.0 or
greater.
Voltage
value
PASS, LOW
or FAIL
Chr
or
(blank)
Aux Power
Supply
Voltage
Generator
Supply
Voltage
RPM;
then RPM-FORWARD
or RPM-BACKWARDS
Revolutions per Minute (RPM)
Numeric
Value
Enter
Level
Lateral
Width
Enter
Level
Lateral
Width
OR
Program
Workout
Enter
PAUSE
CLEAR
Pedal the machine, then
press and hold the Lateral
Width and Level up and
down arrows (
)
for
three seconds.
Press any up arrow (
)
or down arrow (
) key
to navigate through the
diagnostic tests options.
When (ENTER) is
displayed along with the
Test Name, you must
press the Enter key
to
begin the test.
To exit a test,
press PAUSE CLEAR
twice
. To exit the diagnostics mode
at any time, press the PAUSE CLEAR
button twice within two seconds.
ENTER
NAVIGATE
START
EXIT
Run these diagnostics as part of your preventative maintenance routine.
NOTE: