SUPPORT.OCTANEFITNESS.COM

SERVICE TRAINING

Diagnostics

Message

Center

Description

Matrix

Window 1

Window 2

Window 3

Window 

4

MODEL VERSION 

then

Media

Confi guration:

NO MEDIA, TV-

SHARP, TV-OCTANE, 

or 900MHZ

Model and Software version and 
confi guration information

Model #

Version 

Number

VV.00

M LOWER BOARD 

Model # and Software version of 
Lower Board

Model # of 

lower board

Processor 

Version 

Number

Processor 

Version 

Number

DISPLAY (ENTER)

Checks all LEDs. Use the numeric 
keypad to change the speed of the 
test (0 is slowest, 9 is fastest). When 
you have verifi ed all LEDs, press 
Pause Clear twice to exit this test.

LEDs light

LEDs light

LEDs light 

LEDs light 

LEDs light 

KEYPAD (ENTER);

then

Name of Key pressed

Check all keys. Press each key 
on the keypad and the stationary 
handlebars and listen for the beep 
to verify that each works properly. 
Press Pause Clear twice to exit test.

TEST, PASS, 

or FAIL

Count of 

unique keys 

pressed

BRAKE (ENTER)

then

BRAKE - TESTING

Brake motor test. Press Pause Clear 
twice to exit the test.

Raw brake 

position

Brake 

current

 LATERAL  (ENTER)

Motor test. Press Pause Clear twice 
to exit the test.

LEFT INIT

RIGHT INIT

SEEK

Left motor 

raw value

Left motor 

current

Right motor 

raw value

Right 

motor 

current

PORTS (ENTER)

CSAFE Ports; for factory testing only. 
(Requires a special cable.)

TEST, PASS, 

or FAIL

  BATTERY VOLTAGE

Displays the current charge level 
of the battery. Should be 21.0 or 
greater.

Voltage 

value

PASS, LOW 

or FAIL

Chr

or

(blank)

Aux Power

Supply 

Voltage

Generator 

Supply 

Voltage

RPM;

then RPM-FORWARD 

or RPM-BACKWARDS

Revolutions per Minute (RPM)

Numeric 

Value

                                               

Enter

Level

Lateral

Width

                                         

Enter

Level

Lateral

Width

            

OR

Program

Workout

Enter

PAUSE

CLEAR

Pedal the machine, then 

press and hold the Lateral 
Width and Level up and 
down arrows  (

)

 for 

three seconds.  

Press any up arrow (

or down arrow (

) key

 

to navigate through the 
diagnostic tests options.

When (ENTER) is 
displayed along with the 
Test Name, you must 

press the Enter key

 to 

begin the test. 

To exit a test, 

press PAUSE CLEAR 

twice

. To exit the diagnostics mode 

at any time, press the PAUSE CLEAR 
button twice within two seconds.

ENTER

NAVIGATE

START

EXIT

Run these diagnostics as part of your preventative maintenance routine.

NOTE:

 You can skip this test.

Содержание LX8000

Страница 1: ...Preventative Maintenance and Diagnostics JUNE 2016...

Страница 2: ...on LX8000 Assembly Instructions and Operations Manual LX8000 Service Guide PRO Series LCD Mounting Arm Kit Assembly Instructions Tools Needed Routine Maintenance 2 Phillips screwdriver 10mm 6mm 4mm he...

Страница 3: ...rform the majority of preventative maintenance procedures you only need to remove the Mast Boot and Hood 1 Mast Boot 2 Hood 3 Stabilizer Covers 4 Side Shrouds 5 Trunk 6 Handlebar Covers 7 Top 8 Rear B...

Страница 4: ...ttery Connections cable tie P N 107023 001 stand off cable tie P N 102892 001 screw mount cable tie P N 101416 001 cable tie P N 106786 001 snap in cable tie P N 106085 001 battery connection battery...

Страница 5: ...illow block set screws are loose a knocking sound could occur To prevent unwanted noise use a torque wrench to tighten bolts and set screws to 75 FT LB 102 N M Electrical Inspect PAC Board Connections...

Страница 6: ...llel link bolts lateral link bolts lateral link belt tensioner nut and j hook belt and drive pulley 19mm wrench 17mm wrench 17mm wrench 10mm wrench 13mm wrench jam nut 17mm wrench levelers Mechanical...

Страница 7: ...n hardware to 30 FT LB 41 N M IMPORTANT VERIFY HANDLEBAR CABLES ARE SECURED TO HANDLEBAR COVER AND WRAPPED AROUND THE FRAME USING CABLE TIES Preventative Maintenance bolt handlebar cover frame nut nut...

Страница 8: ...t Raw brake position Brake current LATERAL ENTER Motor test Press Pause Clear twice to exit the test LEFT INIT RIGHT INIT SEEK Left motor raw value Left motor current Right motor raw value Right motor...

Страница 9: ...last reset To quickly access this data when not in diagnostics mode press and hold the Program and Level up arrow keys at the same time To reset machine hours to 0 press and hold the ArmBlaster X Mode...

Страница 10: ...rthlandDriveNorth Suite100 BrooklynPark MN 55428USA OCTANE FITNESS LLC 30V 1A Console Serial Number Location Base Serial Number Location Mark Brue Customer Service Manager USA CANADA LATINAMERICA ASIA...