INSTALLATION
| Specification
982000-AIR-M2-M4-EN03.1 | www.ochsner.com 63
AIR 11 C11B
AIR 18 C11B
ELECTRIC BOOSTER HEATER (M2-1, M2-3):
Phases/nominal voltage/frequency
[~]/[V]/[Hz]
1/230/50
1/230/50
Max. output
[kW]
8.8 (2.9 / 2.9 / 2.9)
8.8 (2.9 / 2.9 / 2.9)
Max. operating current
[A]
38.3 (12.8 / 12.8 / 12.8)
38.3 (12.8 / 12.8 / 12.8)
CONDENSER:
Type
Plate heat exchanger
Plate heat exchanger
Material
Stainless steel 1.4301
Stainless steel 1.4301
Quantity
[pcs]
1
1
Max. refrigerant operating pressure
[bar]
30
30
Max. heat transfer medium operating pressure
[bar]
3
3
Heat transfer medium temperature differential
[K]
5
5
Application range
[°C]
65
65
Heat transfer medium
Water
Water
Test pressure
[bar]
45
45
Heat transfer medium flow rate
[m³/h]
1.7
2.2
Internal pressure differential
[mbar]
205
324
Flow meter
built-in
built-in
Heat sink circulation pump (heat generator pump)
internal
Yonos Para 25/7.5
Yonos Para 25/7.5
Residual head I heat sink system, external, incl. flow me-
ter
[mbar]
446
175
REFRIGERANT CIRCUIT:
No. of refrigerant circuits
[pcs]
1
1
Heat transfer medium
R407C
R407C
Refrigerant full charge
[kg]
9.0
9.0
Defrost technology
Hot gas
Hot gas
COMPRESSOR:
Type
Fully hermetic/scroll
Fully hermetic/scroll
Quantity
[pcs]
1
1
Output levels
1
1
Speed
[rpm]
2900
2900
Voltage/frequency
[V]/[Hz]
230 / 50
230 / 50
Max. operating current
[A]
19.4
28.6
FAN (OUTDOOR UNIT):
Type
Axial
Axial
Quantity
[pcs]
1
1
Voltage/frequency
[V]/[Hz]
230 / 50
230 / 50
Power consumption
[W]
40
68
Max. operating current
[A]
1.40
1.40
EVAPORATOR (OUTDOOR UNIT):
Appliance type
VHS-M 9
VHS-M 14
Dimensions HxWxD
[mm]
1080x1290x960
1080x1290x960
Type
Finned pipe
Finned pipe
Quantity
[pcs]
1
1
Weight
[kg]
93
93
Fin pack material
Copper/aluminium
Copper/aluminium
Casing material
Stainless steel, coated
Stainless steel, coated
Max. refrigerant operating pressure
[bar]
30
30
Relative humidity
[%]
80
80
Heat transfer medium temperature differential
[K]
5.7
5.7
Air flow rate
[m³/h]
3000
4000
Application range min./max
[°C]
-24 / +40
-24 / +40
Sound power level/sound pressure level
[dBA]
52/23
54/26
Sound power level/sound pressure level (in silent mode)
[dBA]
49/20
51/23
i
Information
Data on sound pressure levels refer to operation at
full load at a distance of 10 m (free space). Sound
pressure and sound power levels are given +/-3
dB(A).
i
Information
Silent mode offers four separate time windows
during which the outdoor unit can be operated
with reduced sound levels. It is set via the OTE
controller.
Содержание AIR 11
Страница 2: ......
Страница 91: ...INSTALLATION Declaration of Conformity 982000 AIR M2 M4 EN03 1 www ochsner com 91 16 Declaration of Conformity...
Страница 92: ...INSTALLATION Declaration of Conformity 92 www ochsner com 982000 AIR M2 M4 EN03 1...
Страница 99: ...982000 AIR M2 M4 EN03 1 www ochsner com 99...