49
HIGH PO2
Warning >> at Alarm Set Point value minus .20 (1.00 to 1.40).
Alarm >> at Set Point value, except in Deco then at 1.60 only.
When PO2 (partial pressure of oxygen) increases to the Warn-
ing level; the Up Arrow icon will flash, and the PO2 value will
flash (in place of max Depth) for 10 seconds (Fig. 56).
After 10 seconds, Max Depth is restored. The Up Arrow remains
on solid until PO2 decreases below the Warning level.
If PO2 continues to increase and reaches the Alarm Set Point,
the PO2 value will again replace Max Depth (Fig. 57).
> Max Depth will then be available on the ALT 1 display.
> The PO2 value and Up Arrow icon will flash until PO2
decreases below the Alarm Set Point.
High PO2 in Deco
(Fig. 58)
> The PO2 Alarm Set Point does not apply when in Deco.
> If PO2 reaches 1.60 while at a Deco Stop, the PO2 value
(1.60) with icon will alternate with Deco Stop Depth/Time
once each minute*. *
*
PO2 on for 10 seconds, Deco Stop Depth/Time on for 50 seconds
until PO2 decreases below 1.60, then PO2 will not be displayed.
Fig. 56 - PO2 WARNING
Fig. 57 - PO2 ALARM
(until < Set Point)
Fig. 58 - PO2 ALARM
(at Deco Stop)
alt w/ Stop
Depth/Time