13
Low Battery
Voltage level is checked upon activation and every minute dur-
ing operation on the surface.
• When voltage decreases to the warning level (2.75 volts),
the icon is displayed solid on the Surface Main (Fig. 7a).
• Upon decreasing to a voltage level that will no longer sus-
tain proper operation (2.50 volts), the icon will flash 5 times
and the unit will shut off.
• If a low battery condition exists when the unit is activated
(by pressing the button), the graphic bAT and the icon will
appear flashing for 5 seconds and the unit will shut off.
• If the button is not pressed to activate the unit prior to a dive,
and a low battery condition exists, the icon will appear flash-
ing as a warning upon descent to 5 FT (1.5 M) and no other
information will be displayed.
• If a low battery condition occurs during a dive, there will
be sufficient battery power to maintain operation for the
remainder of that dive. The icon will appear, with the graph-
ics CHG and BAT alternating (Fig. 8), after the dive when
operation enters Surface Mode.
Fig. 7 - LOW BATTERY
WARNING
a
Fig. 8 - LOW BATTERY
(occurred during dive)