PRODUCT SP5 SERVICE GUIDE
14
SUPPORT: TOLL‐FREE: 800‐435‐3483 | FAX: 510‐569‐5404 | EMAIL:
G. Insert the threaded end of the
DIN FILTER RETAINER (10)
through the
DIN COUPLER WHEEL (12)
, into the
DIN FILTER
HOUSING (15)
, and hand‐tighten until secure. Apply a 1/4" hex key socket and tighten
to a torque of
16‐18 ft/lbs (21.7‐24.4
N‐m)
(if the
DIN FILTER HOUSING (15)
has a hex machined into its Inner Bore) or
120 to 140 in/lbs (13.6‐15.8 N‐m)
(if it does
not have the hex)
(Fig. 20)
.
Fig. 20
10DVT.
DVT
Yoke
Connector
Reassembly:
A.
Install
PLUNGER (31)
,
PLUNGER SPRING (32)
and
FILTER (33)
into the
DVT YOKE RETAINER (30) (Fig. 21)
.
Fig. 21
B. Place the
DVT YOKE RETAINER (30)
plunger side down onto a clean flat surface; place a lubricated
DVT O‐RING (34)
onto
the
FILTER (33)
. Apply a small pin punch
thru the
O‐RING (34)
and lightly depress the filter, plunger spring and plunger and
hold in place; carefully work the
O‐RING (34)
into the retainer with a brass pick until fully seated, being careful not to damage
the o‐ring
(Fig. 22)
. Once this o‐ring is seated, it will hold the plunger/plunger spring/filter components in place. Now install
the lubricated
DVT YOKE RETAINER O‐RING (35)
into the base of the retainer.
Fig. 22