Oceanic OCL Скачать руководство пользователя страница 29

29

OCL OPERATING MANUAL

© 2002 Design, 2014

Doc. No. 12-5378-r01 (4/9/15)

SAFETY STOP MAIN,

 information includes (Fig. 73):

>  Current Depth with FT (or M) icon

>  DTR (min) with NDC (or O2) and min icons

>  Stop Depth set with FT (or M) icon

>  Stop icon (arrows/bar)

>  Stop Time set with min and sec icons, counting down

> TLBG

>  Gas 1 (or 2) icon, the one in use

•  A (< 2 sec) - to access ALTs**.

•  M (2 sec) - to access Gas Switching.

•  S (< 2 sec) - to acknowledge alarms.

•  L (press) - to operate the Backlight.

** SS features up to 3 ALT displays which are similar to the No Deco Main, ALT1, and ALT2 displays, respectively.

-------------------------------------------------------------------------------------------------------------------

DECOMPRESSION

Decompression mode activates when theoretical No Decompression time and depth limits are exceeded.  

Upon entry into Deco, the audible will sound and the alarm LED will flash.  The full TLBG and Up Arrow/Stop Bar icons will 

flash. 

•  S (< 2 sec) - to silence Audible.  The TLBG will stop flashing.

>  Once within 10 FT (3 M) below the required Stop Depth (stop zone), the full Stop icon (both Arrows with Stop Bar) 

will be displayed solid.

To fulfill your decompression obligation, you should make a safe controlled Ascent to a depth slightly deeper than, or equal 

to, the required Stop Depth indicated and decompress for the Stop Time indicated.

The amount of decompression credit time that you receive is dependent on Depth, with slightly less credit given the deeper 

you are below the Stop Depth indicated.  

You should stay slightly deeper than the required Stop Depth indicated until the next shallower Stop Depth appears.  Then, 

you can slowly ascend to, but not shallower than that indicated Stop Depth. 

DECO STOP MAIN, 

information includes (Fig. 75) -

>  Current Depth with FT (or M) icon

>  TAT (Total Ascent Time)* with TAT and min icons

>  Stop Depth with FT (or M) icon

>  Stop icon (arrows/bar)

>  Stop Time with min icon

>  Full TLBG with icon

>  Gas 1 (or 2) icon, the one in use

•  A (< 2 sec) - to access ALTs.

•  M (< 2 sec) - to apply a snapshot Earmark to the PC/Mac interface data recorded at that time.  

The graphics EAr MAR will 

be displayed for 3 seconds (Fig. 76).

•  M (2 sec) - to access Gas Switching.

•  S (< 2 sec) - to acknowledge alarms.

•  L (press) - to operate the Backlight.

Deco Stop Alt 1,

 information includes  (Fig. 77) -

>  Max Depth with MAX and FT (or M) icons

>  EDT (Elapsed Dive Time) with DIVE and min icons

•  A (< 2 sec) - to access ALT 2.

•  Revert to the Main in 10 seconds, if A is not pressed.

•  L (press) - to operate the Backlight.

Deco Stop Alt 2,

 information includes  (Fig. 78) -

>  Time of Day (hr:min)

>  Temperature with ° icon and graphic F (or C)

•  A (< 2 sec) - to access ALT 3 (if Nitrox), or revert to the Main if not.

•  Revert to the Main in 10 seconds, if A is not pressed.

•  L (press) - to operate the Backlight.

Fig. 74  - DECO ENTRY

(during audible)

Fig. 75  - DECO STOP MAIN

*TAT includes Stop Times at 

all required Deco Stops plus 

vertical Ascent Time based on 

the max rate allowed.

Fig. 78 - DECO STOP ALT 2

Fig. 77 - DECO STOP ALT 1

Fig. 73 - SS MAIN

Fig. 76 - EARMARK

(shown for 3 seconds)

Содержание OCL

Страница 1: ...1 OCL OPERATING MANUAL 2002 Design 2014 Doc No 12 5378 r01 4 9 15 OCL WATCH DIVE COMPUTER OPERATING MANUAL...

Страница 2: ...e 22 SELECT DIVE OP MODE 22 HISTORY NORM GAUG 23 SERIAL NUMBER 23 DIVE MODE FEATURES 24 BAR GRAPHS 25 TLBG NORM FREE 25 VARI NORM GAUG 25 ALGORITHM 25 CONSERVATIVE FACTOR CF 25 DEEP STOP DS 25 SAFETY...

Страница 3: ...arks trade names and service marks of Oceanic All rights are reserved PATENT NOTICE U S Patents have been issued or applied for to protect the following design features Data Sensing and Processing Dev...

Страница 4: ...4 OCL OPERATING MANUAL 2002 Design 2014 Doc No 12 5378 r01 4 9 15 Welcome to OCEANIC and THANK YOU for choosing the OCL...

Страница 5: ...5 OCL OPERATING MANUAL 2002 Design 2014 Doc No 12 5378 r01 4 9 15 FEATURES FUNCTIONS AND WATCH MODE...

Страница 6: ...Time EL Elevation altitude FO2 Fraction of Oxygen FORM Format date time FPM Feet Per Minute FREE Free Dive Mode FT Feet depth GAUG Digital Gauge Dive Mode GLO Glow backlight HR Hour HIST History LO Lo...

Страница 7: ...as Menu Set A Alarms Menu Set U Utilities Menu Set M Mode Menu Set FA Free Alarms Menu Each Menu has a start first selection and a stop last selection Upon entering a Menu movement through it begins a...

Страница 8: ...er FREE Dive Elapsed Dive Time Alarm 3 beeps every 30 seconds if set On FREE Dive Depth Alarms 1 2 3 set sequentially deeper each 3 beeps 3 times FREE Dive TLBG Alarm Caution zone 4 segments 3 beeps 3...

Страница 9: ...___________________________________________ WATCH MODE WATCH MAIN TIME Selection of Main Time is a Set T Time menu item Time of Day and Date can be set when either Home or Away time is selected as the...

Страница 10: ...ions S 2 sec to save the selection If OFF or ON is selected revert to the Lead in screen If SET is selected access the Set CDT screen Set CDT information includes Fig 8 Graphics SEt and CDT CDT hr min...

Страница 11: ...s A 2 sec to step forward to the Set T Lead in M 2 sec to step back to the Chrono Lead in Daily Alarm Status information includes Fig 13 Alarm speaker icon Alarm Time set hr min with colon flashing an...

Страница 12: ...d through Hour Set Points 8 per second from 12 AM to 11 PM or 0 to 23 if 24 Hour Format in increments of 1 hr A 2 sec to step upward through Hour Set Points one at a time M 2 sec to step back through...

Страница 13: ...erential will change Away Time based on Home Time the hours set with this feature Select Main Time information includes Fig 22 This feature selects which Time Home or Away is to be displayed as the Wa...

Страница 14: ...been taken within the past 24 hours NORM is the default upon access from Watch Mode Others can be accessed while on the surface using the Set M Dive Operating Mode selection At any time while operatin...

Страница 15: ...15 OCL OPERATING MANUAL 2002 Design 2014 Doc No 12 5378 r01 4 9 15 NORM SURFACE MODES...

Страница 16: ...ve has been conducted bypassed to Fly Sat if not A hold to scroll forward through Menu items M 2 sec to step back to ALT 1 L press to operate the Backlight NORM SURF ALT 3 information includes Fig 27...

Страница 17: ...FT 9 to 57 M with Plan times based upon the previous dive profiles in a series of repetitive dives and taking into account descent and ascent rates of 60 FPM 18 MPM If less then 1 minute time is avai...

Страница 18: ...on All segments flashing if a Delayed Violation No TLBG if Gauge Mode VARI max Ascent Rate sustained for 4 seconds S 2 sec to access Data 2 for that dive S 2 sec to revert to Preview screen L press to...

Страница 19: ...O2 Set Points S 2 sec save the FO2 setting and flash the PO2 digits if Nitrox a numerical value or access Set Gas 2 if Air S 2 sec to step back to the Set Gas Lead in screen without changing the Gas 1...

Страница 20: ...DT Elapsed Dive Time Alarm information includes Fig 42 Graphics SEt and EDT Time value flashing with DIVE and min icons A hold to scroll upward through Set Points 8 per second from OFF to 10 through 1...

Страница 21: ...Stop S 2 sec to step back to Set Wet Activation without changing the Units setting Set Deep Stop DS information includes Fig 49 Graphics SEt and DS Graphic ON or OFF flashing A or M 2 sec to toggle b...

Страница 22: ...access Set Sampling Rate S 2 sec to step back to Set Conservative Factor without changing the Backlight Duration setting Backlight Glo Duration is the time the backlight will remain On after L is rel...

Страница 23: ...ic F or C lowest recorded Max Depth ever reached to 330 FT 100 M with MAX and FT or M icons Longest Elapsed Dive Time EDT recorded during a single dive up to 599 min with DIVE and min icons S 2 sec to...

Страница 24: ...24 OCL OPERATING MANUAL 2002 Design 2014 Doc No 12 5378 r01 4 9 15 DIVE MODE FEATURES...

Страница 25: ...Pelagic Z performance is based on Buhlmann ZHL 16c It features NDLs that are considerably more conserva tive especially at shallower depths To create even greater margins of safety with respect to dec...

Страница 26: ...TR NDC is the maximum amount of time that you can stay at your present Depth before entering Decompression It is calcu lated based on the amount of nitrogen absorbed by hypothetical tissue compartment...

Страница 27: ...27 OCL OPERATING MANUAL 2002 Design 2014 Doc No 12 5378 r01 4 9 15 NORM DIVE MODE...

Страница 28: ...r Format no icon if 24 Hour Format Temperature with graphic F or C A 2 sec to access ALT 2 if Nitrox or access DS Preview if not Revert to the Main in 10 seconds if A is not pressed L press to operate...

Страница 29: ...er you are below the Stop Depth indicated You should stay slightly deeper than the required Stop Depth indicated until the next shallower Stop Depth appears Then you can slowly ascend to but not shall...

Страница 30: ...TLBG will flash for 10 seconds Fig 81 The difference is that 5 minutes after surfacing from the dive operation will now enter Violation Gauge Mode Down Arrow icon continues to flash until descent to b...

Страница 31: ...n Dsat and FREE Mode features screens The Fly countdown indicates time remaining before normal operation can resume with full features and functions HIGH PO2 NORM ONLY Warning at Alarm value minus 20...

Страница 32: ...lue with icon will flash in place of TAT until on the surface Max Depth and EDT will be displayed in place of Deco Stop Depth Time similar to Fig 90 S 2 sec to acknowledge alarm A 2 sec to access ALTs...

Страница 33: ...nds if M or S is not pressed Gas Switch Alarm If the Switch to a Gas would result in PO2 1 60 the audible will sound and after 2 seconds a Don t Change warn ing message will flash Fig 93 until acknowl...

Страница 34: ...34 OCL OPERATING MANUAL 2002 Design 2014 Doc No 12 5378 r01 4 9 15 DIGITAL GAUGE MODE...

Страница 35: ...usly conducted while still in GAUG mode with MAX and FT or M icons EDT Elapsed Dive Time up to 599 min with DIVE and min icons Dashes if no previous dive conducted A 2 sec to access ALT 2 A hold to sc...

Страница 36: ...ll be continued Surface time will not be added to Dive Time After 10 minutes elapse operation will revert to the Watch Main Time screen GAUG DIVE ALT 1 information includes Fig 99A B Graphic TMR run t...

Страница 37: ...37 OCL OPERATING MANUAL 2002 Design 2014 Doc No 12 5378 r01 4 9 15 FREE DIVE MODE...

Страница 38: ...step back to ALT 1 L press to operate the Backlight FREE SURF MENU Button operations A 2 sec step forward through Menu items A hold scroll forward through Menu items M 2 sec step back through Menu ite...

Страница 39: ...to access Set EDT Alarm EDT ELAPSED DIVE TIME ALARM Factory set for a fixed 30 seconds the EDT alarm sounds the audible every 30 seconds during FREE dives Set EDT Alarm information includes Fig 109 G...

Страница 40: ...RF icon flashing for the first 1 minute and NDC will be displayed as 2 dashes Fig 113 After 1 minute elapses operation will revert to Surface Mode and full access given to the FREE Surface Menu items...

Страница 41: ...digits will flash on the Main Fig 124 FREE Depth Alarms When set On the Depth alarms 1 2 3 activate at their respective set Depths during descent The audible will sound dur ing which time the Depth di...

Страница 42: ...42 OCL OPERATING MANUAL 2002 Design 2014 Doc No 12 5378 r01 4 9 15 REFERENCE...

Страница 43: ...Interface by installing the contact side of the watch first Removal should be the reverse order removing the contact side last The OCL must be in Watch Mode to interface with a PC or MAC computer The...

Страница 44: ...your original sales receipt and Warranty Registration Card Send freight prepaid and insured using a traceable method to the nearest Oceanic Regional Facility or to Oceanic USA If shipping to Oceanic U...

Страница 45: ...sealing O ring replacement is required each time the Battery is replaced Battery Installation NOTE The O ring must be a genuine Oceanic part available at an Authorized Oceanic Dealer Use of any other...

Страница 46: ...roviding corrected Depth and reduced No Deco and O2 Times at intervals of 1 000 feet 305 meters When the Conservative Factor is set On NDLs are calculated based upon the next higher 3 000 foot 915 met...

Страница 47: ...47 OCL OPERATING MANUAL 2002 Design 2014 Doc No 12 5378 r01 4 9 15 TECHNICAL DATA...

Страница 48: ...05 0 05 0 05 0 05 150 0 08 0 06 0 06 0 06 0 05 0 05 0 05 0 05 0 05 0 04 0 04 0 04 160 0 07 0 06 0 05 0 05 0 05 0 05 0 05 0 04 0 04 0 04 0 04 0 04 170 0 07 0 05 0 05 0 05 0 04 0 04 0 04 0 04 0 04 0 04...

Страница 49: ...3 0 03 0 03 0 03 180 0 05 0 04 0 04 0 04 0 03 0 03 0 03 0 03 0 03 0 03 0 03 0 03 190 0 04 0 04 0 04 0 03 0 03 0 03 0 03 0 03 0 03 0 03 0 03 0 00 Z BASED NDLS HR MIN METRIC Altitude 0 916 1221 1526 183...

Страница 50: ...mory and deletes the older dive Altitude Operational from sea level to 14 000 feet 4 270 meters elevation Measures ambient pressure every 30 minutes in Watch mode when Dive Computer mode is accessed a...

Страница 51: ...starting 10 min after the dive NUMERIC DISPLAYS Range Resolution NORM GAUG Modes Surface Interval 0 00 to 23 59 hr min 1 minute Dive No 0 to 24 1 Elapsed Dive Time 00 to 599 min 1 minute FO2 Set Poin...

Страница 52: ...www OceanicWorldwide com E mail hello oceanicusa com OCEANIC NORTHERN EUROPE Augsburg Germany Tel 49 0 821 810342 0 Fax 49 0 821 810342 29 Web www oceanic de E mail office oceanic de OCEANIC ITALY Gen...

Страница 53: ...53 OCL OPERATING MANUAL 2002 Design 2014 Doc No 12 5378 r01 4 9 15 OCL WATCH DIVE COMPUTER OPERATING MANUAL...

Отзывы: