Oceanic OCL Скачать руководство пользователя страница 17

17

OCL OPERATING MANUAL

© 2002 Design, 2014

Doc. No. 12-5378-r01 (4/9/15)

FLY/SAT,

 information includes (Fig. 28A, B):

>  Graphic FLY with Time to Fly (hr:min), - : - - if no dive yet

>  Graphic SAT with Time to Desat (hr:min), - : - - if no dive yet, 0:00 if no time remaining

•  A (< 2 sec) - to access Plan.

•  A (hold) - to scroll forward through Menu items.

•  M (< 2 sec) - to step back to ALT 3 (if Nitrox), or ALT 2 (if not).

•  L (press) - to operate the Backlight.

PLAN MODE (NORM) 

No Deco Dive Times (NDLs/OTLs) in Plan Mode are based on -

>  the algorithm selected (DSAT or PZ+)

>  the FO2 set (for Gas 1 only, the default for Plan)

>  the setting for the Conservative Factor (Off or On*)

>  any residual nitrogen or oxygen remaining from previous dives (NORM or FREE)

*When the Conservative Factor is set On, Dive times are reduced to the values of the next higher 3000 foot (915 

meter) Altitude.  Refer to tables in back.

Plan Lead-in,

 information includes (Fig. 29A, B):

>  Graphic PLAN

>  Graphic dSAt or PZ, the algorithm selected (DSAT or PZ+)

>  PO2 alarm value set (ATA) for Gas 1 with icon, blank if Air 

>  FO2 set for Gas 1 with icon, graphic Air or numeric value (21 to 100)

>  Gas (tank) 1 icon, default gas for Plan

•  A (< 2 sec) - to access Log.

•  A (hold) - to scroll forward through Menu items.

•  M (< 2 sec) - to step back to FLY/SAT.

•  S (< 2 sec) - to access the Pre Dive Planning Sequence.

•  L (press) - to operate the Backlight.

PDPS (Pre Dive Planning Sequence)

The PDPS displays Depths and allowable No Deco Dive Times (up to 999 minutes), as NDLs (nitrogen based limits) if nitro-

gen is in control or OTLs (oxygen based limits) if O2 is in control.  

It will sequence through depth/time screens displaying Depths from 30 to 190 FT (9 to 57 M) with Plan times* based upon 

the previous dive profiles in a series of repetitive dives and taking into account descent and ascent rates of 60 FPM (18 

MPM).

*If less then 1 minute time is available, dashes will be displayed for time, and depth values will flash.

  

PDPS,

 information includes (Fig. 30A, B):

>  Plan Depth value with FT (or M) icon

>  Dive Time allowed with NDC (or OTL) and min icons

>  Max Depth allowed for the PO2 alarm value set for Gas 1 with MAX and FT (or M) icons, blank if FO2 is set for Air 

>  FO2 set for Gas 1 with icon, graphic Air or numeric value (21 to 100)

>  Gas (tank) 1 icon, default gas for Plan

•  A (< 2 sec) - to step forward through PDPS screens.

•  A (hold) - to scroll forward through PDPS screens 8 per second from 30 to 190 FT (9 to 57 M) in increments of 10 FT 

(3 M).

•  M (< 2 sec) - to step back through PDPS screens.

•  S (< 2 sec) - to revert to the Lead-in after the last screen.

•  S (2 sec) - to revert to the Lead-in screen.

•  L (press) - to operate the Backlight.

LOG MODE (NORM/GAUG)

 

Information from the latest 24 NORM and/or GAUG dives** is stored for viewing.   

>  After exceeding 24 dives, the most recent dive is stored while the oldest is deleted. 

>  Dives are numbered from 1 to 24 starting each time NORM (or GAUG) Dive Mode is activated.  After the post dive 24 

hour period has elapsed and the unit shuts off, the first dive of the next activation period will be #1.

>  In the event that a dive’s elapsed time (EDT) exceeds 599 (min), the data at the 599 interval is recorded in the Log 

upon surfacing of the unit.

**FREE Dive information is only available using the OceanLog PC or Diverlog for Mac Interface program.

Fig. 28A - FLY/SAT

(no dive yet)

Fig. 28B - FLY/SAT

(after a dive)

Fig. 29A - PLAN LEAD-IN

(Gas 1 set for Air)

Fig. 29B - PLAN LEAD-IN

(Gas 1 set for Nitrox)

Fig. 30A - PDPS

(nitrogen control)

Fig. 30B - PDPS

(oxygen control)

Содержание OCL

Страница 1: ...1 OCL OPERATING MANUAL 2002 Design 2014 Doc No 12 5378 r01 4 9 15 OCL WATCH DIVE COMPUTER OPERATING MANUAL...

Страница 2: ...e 22 SELECT DIVE OP MODE 22 HISTORY NORM GAUG 23 SERIAL NUMBER 23 DIVE MODE FEATURES 24 BAR GRAPHS 25 TLBG NORM FREE 25 VARI NORM GAUG 25 ALGORITHM 25 CONSERVATIVE FACTOR CF 25 DEEP STOP DS 25 SAFETY...

Страница 3: ...arks trade names and service marks of Oceanic All rights are reserved PATENT NOTICE U S Patents have been issued or applied for to protect the following design features Data Sensing and Processing Dev...

Страница 4: ...4 OCL OPERATING MANUAL 2002 Design 2014 Doc No 12 5378 r01 4 9 15 Welcome to OCEANIC and THANK YOU for choosing the OCL...

Страница 5: ...5 OCL OPERATING MANUAL 2002 Design 2014 Doc No 12 5378 r01 4 9 15 FEATURES FUNCTIONS AND WATCH MODE...

Страница 6: ...Time EL Elevation altitude FO2 Fraction of Oxygen FORM Format date time FPM Feet Per Minute FREE Free Dive Mode FT Feet depth GAUG Digital Gauge Dive Mode GLO Glow backlight HR Hour HIST History LO Lo...

Страница 7: ...as Menu Set A Alarms Menu Set U Utilities Menu Set M Mode Menu Set FA Free Alarms Menu Each Menu has a start first selection and a stop last selection Upon entering a Menu movement through it begins a...

Страница 8: ...er FREE Dive Elapsed Dive Time Alarm 3 beeps every 30 seconds if set On FREE Dive Depth Alarms 1 2 3 set sequentially deeper each 3 beeps 3 times FREE Dive TLBG Alarm Caution zone 4 segments 3 beeps 3...

Страница 9: ...___________________________________________ WATCH MODE WATCH MAIN TIME Selection of Main Time is a Set T Time menu item Time of Day and Date can be set when either Home or Away time is selected as the...

Страница 10: ...ions S 2 sec to save the selection If OFF or ON is selected revert to the Lead in screen If SET is selected access the Set CDT screen Set CDT information includes Fig 8 Graphics SEt and CDT CDT hr min...

Страница 11: ...s A 2 sec to step forward to the Set T Lead in M 2 sec to step back to the Chrono Lead in Daily Alarm Status information includes Fig 13 Alarm speaker icon Alarm Time set hr min with colon flashing an...

Страница 12: ...d through Hour Set Points 8 per second from 12 AM to 11 PM or 0 to 23 if 24 Hour Format in increments of 1 hr A 2 sec to step upward through Hour Set Points one at a time M 2 sec to step back through...

Страница 13: ...erential will change Away Time based on Home Time the hours set with this feature Select Main Time information includes Fig 22 This feature selects which Time Home or Away is to be displayed as the Wa...

Страница 14: ...been taken within the past 24 hours NORM is the default upon access from Watch Mode Others can be accessed while on the surface using the Set M Dive Operating Mode selection At any time while operatin...

Страница 15: ...15 OCL OPERATING MANUAL 2002 Design 2014 Doc No 12 5378 r01 4 9 15 NORM SURFACE MODES...

Страница 16: ...ve has been conducted bypassed to Fly Sat if not A hold to scroll forward through Menu items M 2 sec to step back to ALT 1 L press to operate the Backlight NORM SURF ALT 3 information includes Fig 27...

Страница 17: ...FT 9 to 57 M with Plan times based upon the previous dive profiles in a series of repetitive dives and taking into account descent and ascent rates of 60 FPM 18 MPM If less then 1 minute time is avai...

Страница 18: ...on All segments flashing if a Delayed Violation No TLBG if Gauge Mode VARI max Ascent Rate sustained for 4 seconds S 2 sec to access Data 2 for that dive S 2 sec to revert to Preview screen L press to...

Страница 19: ...O2 Set Points S 2 sec save the FO2 setting and flash the PO2 digits if Nitrox a numerical value or access Set Gas 2 if Air S 2 sec to step back to the Set Gas Lead in screen without changing the Gas 1...

Страница 20: ...DT Elapsed Dive Time Alarm information includes Fig 42 Graphics SEt and EDT Time value flashing with DIVE and min icons A hold to scroll upward through Set Points 8 per second from OFF to 10 through 1...

Страница 21: ...Stop S 2 sec to step back to Set Wet Activation without changing the Units setting Set Deep Stop DS information includes Fig 49 Graphics SEt and DS Graphic ON or OFF flashing A or M 2 sec to toggle b...

Страница 22: ...access Set Sampling Rate S 2 sec to step back to Set Conservative Factor without changing the Backlight Duration setting Backlight Glo Duration is the time the backlight will remain On after L is rel...

Страница 23: ...ic F or C lowest recorded Max Depth ever reached to 330 FT 100 M with MAX and FT or M icons Longest Elapsed Dive Time EDT recorded during a single dive up to 599 min with DIVE and min icons S 2 sec to...

Страница 24: ...24 OCL OPERATING MANUAL 2002 Design 2014 Doc No 12 5378 r01 4 9 15 DIVE MODE FEATURES...

Страница 25: ...Pelagic Z performance is based on Buhlmann ZHL 16c It features NDLs that are considerably more conserva tive especially at shallower depths To create even greater margins of safety with respect to dec...

Страница 26: ...TR NDC is the maximum amount of time that you can stay at your present Depth before entering Decompression It is calcu lated based on the amount of nitrogen absorbed by hypothetical tissue compartment...

Страница 27: ...27 OCL OPERATING MANUAL 2002 Design 2014 Doc No 12 5378 r01 4 9 15 NORM DIVE MODE...

Страница 28: ...r Format no icon if 24 Hour Format Temperature with graphic F or C A 2 sec to access ALT 2 if Nitrox or access DS Preview if not Revert to the Main in 10 seconds if A is not pressed L press to operate...

Страница 29: ...er you are below the Stop Depth indicated You should stay slightly deeper than the required Stop Depth indicated until the next shallower Stop Depth appears Then you can slowly ascend to but not shall...

Страница 30: ...TLBG will flash for 10 seconds Fig 81 The difference is that 5 minutes after surfacing from the dive operation will now enter Violation Gauge Mode Down Arrow icon continues to flash until descent to b...

Страница 31: ...n Dsat and FREE Mode features screens The Fly countdown indicates time remaining before normal operation can resume with full features and functions HIGH PO2 NORM ONLY Warning at Alarm value minus 20...

Страница 32: ...lue with icon will flash in place of TAT until on the surface Max Depth and EDT will be displayed in place of Deco Stop Depth Time similar to Fig 90 S 2 sec to acknowledge alarm A 2 sec to access ALTs...

Страница 33: ...nds if M or S is not pressed Gas Switch Alarm If the Switch to a Gas would result in PO2 1 60 the audible will sound and after 2 seconds a Don t Change warn ing message will flash Fig 93 until acknowl...

Страница 34: ...34 OCL OPERATING MANUAL 2002 Design 2014 Doc No 12 5378 r01 4 9 15 DIGITAL GAUGE MODE...

Страница 35: ...usly conducted while still in GAUG mode with MAX and FT or M icons EDT Elapsed Dive Time up to 599 min with DIVE and min icons Dashes if no previous dive conducted A 2 sec to access ALT 2 A hold to sc...

Страница 36: ...ll be continued Surface time will not be added to Dive Time After 10 minutes elapse operation will revert to the Watch Main Time screen GAUG DIVE ALT 1 information includes Fig 99A B Graphic TMR run t...

Страница 37: ...37 OCL OPERATING MANUAL 2002 Design 2014 Doc No 12 5378 r01 4 9 15 FREE DIVE MODE...

Страница 38: ...step back to ALT 1 L press to operate the Backlight FREE SURF MENU Button operations A 2 sec step forward through Menu items A hold scroll forward through Menu items M 2 sec step back through Menu ite...

Страница 39: ...to access Set EDT Alarm EDT ELAPSED DIVE TIME ALARM Factory set for a fixed 30 seconds the EDT alarm sounds the audible every 30 seconds during FREE dives Set EDT Alarm information includes Fig 109 G...

Страница 40: ...RF icon flashing for the first 1 minute and NDC will be displayed as 2 dashes Fig 113 After 1 minute elapses operation will revert to Surface Mode and full access given to the FREE Surface Menu items...

Страница 41: ...digits will flash on the Main Fig 124 FREE Depth Alarms When set On the Depth alarms 1 2 3 activate at their respective set Depths during descent The audible will sound dur ing which time the Depth di...

Страница 42: ...42 OCL OPERATING MANUAL 2002 Design 2014 Doc No 12 5378 r01 4 9 15 REFERENCE...

Страница 43: ...Interface by installing the contact side of the watch first Removal should be the reverse order removing the contact side last The OCL must be in Watch Mode to interface with a PC or MAC computer The...

Страница 44: ...your original sales receipt and Warranty Registration Card Send freight prepaid and insured using a traceable method to the nearest Oceanic Regional Facility or to Oceanic USA If shipping to Oceanic U...

Страница 45: ...sealing O ring replacement is required each time the Battery is replaced Battery Installation NOTE The O ring must be a genuine Oceanic part available at an Authorized Oceanic Dealer Use of any other...

Страница 46: ...roviding corrected Depth and reduced No Deco and O2 Times at intervals of 1 000 feet 305 meters When the Conservative Factor is set On NDLs are calculated based upon the next higher 3 000 foot 915 met...

Страница 47: ...47 OCL OPERATING MANUAL 2002 Design 2014 Doc No 12 5378 r01 4 9 15 TECHNICAL DATA...

Страница 48: ...05 0 05 0 05 0 05 150 0 08 0 06 0 06 0 06 0 05 0 05 0 05 0 05 0 05 0 04 0 04 0 04 160 0 07 0 06 0 05 0 05 0 05 0 05 0 05 0 04 0 04 0 04 0 04 0 04 170 0 07 0 05 0 05 0 05 0 04 0 04 0 04 0 04 0 04 0 04...

Страница 49: ...3 0 03 0 03 0 03 180 0 05 0 04 0 04 0 04 0 03 0 03 0 03 0 03 0 03 0 03 0 03 0 03 190 0 04 0 04 0 04 0 03 0 03 0 03 0 03 0 03 0 03 0 03 0 03 0 00 Z BASED NDLS HR MIN METRIC Altitude 0 916 1221 1526 183...

Страница 50: ...mory and deletes the older dive Altitude Operational from sea level to 14 000 feet 4 270 meters elevation Measures ambient pressure every 30 minutes in Watch mode when Dive Computer mode is accessed a...

Страница 51: ...starting 10 min after the dive NUMERIC DISPLAYS Range Resolution NORM GAUG Modes Surface Interval 0 00 to 23 59 hr min 1 minute Dive No 0 to 24 1 Elapsed Dive Time 00 to 599 min 1 minute FO2 Set Poin...

Страница 52: ...www OceanicWorldwide com E mail hello oceanicusa com OCEANIC NORTHERN EUROPE Augsburg Germany Tel 49 0 821 810342 0 Fax 49 0 821 810342 29 Web www oceanic de E mail office oceanic de OCEANIC ITALY Gen...

Страница 53: ...53 OCL OPERATING MANUAL 2002 Design 2014 Doc No 12 5378 r01 4 9 15 OCL WATCH DIVE COMPUTER OPERATING MANUAL...

Отзывы: