NORM SURF MAIN

, information includes (Fig. 24A):

>  Surface Interval time (hr:min) with SURF icon; if no dive yet, this is time since activation

>  Time of Day (hr:min) with AM or PM icon if 12 Hour Format; no icon if 24 Hour Format

>  Graphic NOR

>  Dive number with DIVE icon, up to 24 for that operating period (0 if no dive made yet)

>  Gas 1 icon, default in Surface Mode

>  TLBG with icon, if any after a NORM or FREE dive

>  Battery icon, if voltage is low

•  A (< 2 sec) - to access ALT 1. 

•  A (hold) - to scroll forward through NORM Surface Menu items.

•  M (< 2 sec) - to access the SN (serial number).

•  M (2 sec) - to access the Watch Main Time screen.

•  L (< 2 sec) - to toggle the Backlight On/Off.

•  L (2 sec), while the Backlight is On - to reset the timer and keep it On for the duration set.

Upon surfacing during dives, the Dive Main will remain on display for the first 10 minutes with Surface Interval time (SI) 

in place of Depth (Fig. 24B) after which the post dive Surface Main will be displayed (Fig. 24C).

NORM SURF ALT 1

, information includes (Fig. 25):

>  Surface Interval* (hr:min) with SURF icon, prior to Last dive

>  Graphic LAST, indicating data is for dive previously conducted while still in NORM mode 

>  Max Depth* of dive previously conducted while still in NORM mode with MAX and FT (or M) icons

>  EDT* (Elapsed Dive Time up to 599 min) with DIVE and min icons

*Dashes if no previous dive conducted.

•  A (< 2 sec) - to access ALT 2. 

•  A (hold) - to scroll forward through Menu items.

•  M (< 2 sec) - to step back to Surface Main.

•  L (press) - to operate the Backlight.

NORM SURF ALT 2

, information includes (Fig. 26):

>  Temperature with graphic F (or C)

>  Altitude graphic, if EL2 (to EL7), blank if Sea level

•  A (< 2 sec) - to access ALT 3 (if a Nitrox dive has been conducted, bypassed to Fly/Sat if not). 

•  A (hold) - to scroll forward through Menu items.

•  M (< 2 sec) - to step back to ALT 1.

•  L (press) - to operate the Backlight.

NORM SURF ALT 3

, information includes (Fig. 27):

>  Current O2 (%) with O2sat icon

>  PO2 alarm value set (ATA) with PO2 and MAX icons 

>  FO2 set for Gas 1 with FO2 icon

>  NX icon, if FO2 is set for Nitrox

>  (PZ+) icon, if selected, no icon if DSAT is selected

>  CF icon, if Conservative Factor is set On

>  Gas 1 icon, default on surface

•  A (< 2 sec) - to access Fly/Sat.

•  A (hold) - to scroll forward through Menu items.

•  M (< 2 sec) - to step back to ALT 2.

•  L (press) - to activate Backlight.

FLY/SAT TIME

 

Time to Fly is a countdown timer that begins counting down from 23:50 to 0:00 (hr:min) 10 minutes after surfacing from a 

dive (NORM, GAUG, or FREE).

Time to Desaturate (SAT), also a countdown timer, provides calculated time for tissue desaturation at sea level taking into 

consideration the Conservation Factor setting.  It also begins counting down 10 minutes after surfacing from a dive (NORM 

or FREE), counting down from 23 to 10 (hr only), then 9:59 to 0:00 (hr:min). 

When the SAT countdown reaches 0:00, which will generally occur prior to the FLY countdown reaching 0:00, it will remain 

on the display until the FLY countdown reaches 0:00. 

>  When other screens are accessed, the FLY and SAT countdowns continue in the background.

>  SAT is not displayed after a Gauge or Violation dive.

>  Desaturation requiring Times greater than 24 hours will display 24 - until it decreases to 23 (hr) .  

>  In the event that Time to Desaturate still remains at the end of 24 hours, operation as a dive computer will be canceled 

and any Nitrogen/oxygen calculation and remaining SAT time will be cleared.  

Fig. 24C - NORM SURF MAIN

(14 min after dive 1)

Fig. 24A - NORM SURF MAIN

(no dive yet)

Fig. 26 - NORM SURF ALT 2

Fig. 25 - NORM SURF ALT 1

(Last dive's data)

Fig. 27 - NORM SURF ALT 3

(only if Nitrox)

Fig. 24B - NORM DIVE MAIN

(3 min after surfacing)

Содержание OCL

Страница 1: ...1 OCL OPERATING MANUAL 2002 Design 2014 Doc No 12 5378 r01 4 9 15 OCL WATCH DIVE COMPUTER OPERATING MANUAL...

Страница 2: ...e 22 SELECT DIVE OP MODE 22 HISTORY NORM GAUG 23 SERIAL NUMBER 23 DIVE MODE FEATURES 24 BAR GRAPHS 25 TLBG NORM FREE 25 VARI NORM GAUG 25 ALGORITHM 25 CONSERVATIVE FACTOR CF 25 DEEP STOP DS 25 SAFETY...

Страница 3: ...arks trade names and service marks of Oceanic All rights are reserved PATENT NOTICE U S Patents have been issued or applied for to protect the following design features Data Sensing and Processing Dev...

Страница 4: ...4 OCL OPERATING MANUAL 2002 Design 2014 Doc No 12 5378 r01 4 9 15 Welcome to OCEANIC and THANK YOU for choosing the OCL...

Страница 5: ...5 OCL OPERATING MANUAL 2002 Design 2014 Doc No 12 5378 r01 4 9 15 FEATURES FUNCTIONS AND WATCH MODE...

Страница 6: ...Time EL Elevation altitude FO2 Fraction of Oxygen FORM Format date time FPM Feet Per Minute FREE Free Dive Mode FT Feet depth GAUG Digital Gauge Dive Mode GLO Glow backlight HR Hour HIST History LO Lo...

Страница 7: ...as Menu Set A Alarms Menu Set U Utilities Menu Set M Mode Menu Set FA Free Alarms Menu Each Menu has a start first selection and a stop last selection Upon entering a Menu movement through it begins a...

Страница 8: ...er FREE Dive Elapsed Dive Time Alarm 3 beeps every 30 seconds if set On FREE Dive Depth Alarms 1 2 3 set sequentially deeper each 3 beeps 3 times FREE Dive TLBG Alarm Caution zone 4 segments 3 beeps 3...

Страница 9: ...___________________________________________ WATCH MODE WATCH MAIN TIME Selection of Main Time is a Set T Time menu item Time of Day and Date can be set when either Home or Away time is selected as the...

Страница 10: ...ions S 2 sec to save the selection If OFF or ON is selected revert to the Lead in screen If SET is selected access the Set CDT screen Set CDT information includes Fig 8 Graphics SEt and CDT CDT hr min...

Страница 11: ...s A 2 sec to step forward to the Set T Lead in M 2 sec to step back to the Chrono Lead in Daily Alarm Status information includes Fig 13 Alarm speaker icon Alarm Time set hr min with colon flashing an...

Страница 12: ...d through Hour Set Points 8 per second from 12 AM to 11 PM or 0 to 23 if 24 Hour Format in increments of 1 hr A 2 sec to step upward through Hour Set Points one at a time M 2 sec to step back through...

Страница 13: ...erential will change Away Time based on Home Time the hours set with this feature Select Main Time information includes Fig 22 This feature selects which Time Home or Away is to be displayed as the Wa...

Страница 14: ...been taken within the past 24 hours NORM is the default upon access from Watch Mode Others can be accessed while on the surface using the Set M Dive Operating Mode selection At any time while operatin...

Страница 15: ...15 OCL OPERATING MANUAL 2002 Design 2014 Doc No 12 5378 r01 4 9 15 NORM SURFACE MODES...

Страница 16: ...ve has been conducted bypassed to Fly Sat if not A hold to scroll forward through Menu items M 2 sec to step back to ALT 1 L press to operate the Backlight NORM SURF ALT 3 information includes Fig 27...

Страница 17: ...FT 9 to 57 M with Plan times based upon the previous dive profiles in a series of repetitive dives and taking into account descent and ascent rates of 60 FPM 18 MPM If less then 1 minute time is avai...

Страница 18: ...on All segments flashing if a Delayed Violation No TLBG if Gauge Mode VARI max Ascent Rate sustained for 4 seconds S 2 sec to access Data 2 for that dive S 2 sec to revert to Preview screen L press to...

Страница 19: ...O2 Set Points S 2 sec save the FO2 setting and flash the PO2 digits if Nitrox a numerical value or access Set Gas 2 if Air S 2 sec to step back to the Set Gas Lead in screen without changing the Gas 1...

Страница 20: ...DT Elapsed Dive Time Alarm information includes Fig 42 Graphics SEt and EDT Time value flashing with DIVE and min icons A hold to scroll upward through Set Points 8 per second from OFF to 10 through 1...

Страница 21: ...Stop S 2 sec to step back to Set Wet Activation without changing the Units setting Set Deep Stop DS information includes Fig 49 Graphics SEt and DS Graphic ON or OFF flashing A or M 2 sec to toggle b...

Страница 22: ...access Set Sampling Rate S 2 sec to step back to Set Conservative Factor without changing the Backlight Duration setting Backlight Glo Duration is the time the backlight will remain On after L is rel...

Страница 23: ...ic F or C lowest recorded Max Depth ever reached to 330 FT 100 M with MAX and FT or M icons Longest Elapsed Dive Time EDT recorded during a single dive up to 599 min with DIVE and min icons S 2 sec to...

Страница 24: ...24 OCL OPERATING MANUAL 2002 Design 2014 Doc No 12 5378 r01 4 9 15 DIVE MODE FEATURES...

Страница 25: ...Pelagic Z performance is based on Buhlmann ZHL 16c It features NDLs that are considerably more conserva tive especially at shallower depths To create even greater margins of safety with respect to dec...

Страница 26: ...TR NDC is the maximum amount of time that you can stay at your present Depth before entering Decompression It is calcu lated based on the amount of nitrogen absorbed by hypothetical tissue compartment...

Страница 27: ...27 OCL OPERATING MANUAL 2002 Design 2014 Doc No 12 5378 r01 4 9 15 NORM DIVE MODE...

Страница 28: ...r Format no icon if 24 Hour Format Temperature with graphic F or C A 2 sec to access ALT 2 if Nitrox or access DS Preview if not Revert to the Main in 10 seconds if A is not pressed L press to operate...

Страница 29: ...er you are below the Stop Depth indicated You should stay slightly deeper than the required Stop Depth indicated until the next shallower Stop Depth appears Then you can slowly ascend to but not shall...

Страница 30: ...TLBG will flash for 10 seconds Fig 81 The difference is that 5 minutes after surfacing from the dive operation will now enter Violation Gauge Mode Down Arrow icon continues to flash until descent to b...

Страница 31: ...n Dsat and FREE Mode features screens The Fly countdown indicates time remaining before normal operation can resume with full features and functions HIGH PO2 NORM ONLY Warning at Alarm value minus 20...

Страница 32: ...lue with icon will flash in place of TAT until on the surface Max Depth and EDT will be displayed in place of Deco Stop Depth Time similar to Fig 90 S 2 sec to acknowledge alarm A 2 sec to access ALTs...

Страница 33: ...nds if M or S is not pressed Gas Switch Alarm If the Switch to a Gas would result in PO2 1 60 the audible will sound and after 2 seconds a Don t Change warn ing message will flash Fig 93 until acknowl...

Страница 34: ...34 OCL OPERATING MANUAL 2002 Design 2014 Doc No 12 5378 r01 4 9 15 DIGITAL GAUGE MODE...

Страница 35: ...usly conducted while still in GAUG mode with MAX and FT or M icons EDT Elapsed Dive Time up to 599 min with DIVE and min icons Dashes if no previous dive conducted A 2 sec to access ALT 2 A hold to sc...

Страница 36: ...ll be continued Surface time will not be added to Dive Time After 10 minutes elapse operation will revert to the Watch Main Time screen GAUG DIVE ALT 1 information includes Fig 99A B Graphic TMR run t...

Страница 37: ...37 OCL OPERATING MANUAL 2002 Design 2014 Doc No 12 5378 r01 4 9 15 FREE DIVE MODE...

Страница 38: ...step back to ALT 1 L press to operate the Backlight FREE SURF MENU Button operations A 2 sec step forward through Menu items A hold scroll forward through Menu items M 2 sec step back through Menu ite...

Страница 39: ...to access Set EDT Alarm EDT ELAPSED DIVE TIME ALARM Factory set for a fixed 30 seconds the EDT alarm sounds the audible every 30 seconds during FREE dives Set EDT Alarm information includes Fig 109 G...

Страница 40: ...RF icon flashing for the first 1 minute and NDC will be displayed as 2 dashes Fig 113 After 1 minute elapses operation will revert to Surface Mode and full access given to the FREE Surface Menu items...

Страница 41: ...digits will flash on the Main Fig 124 FREE Depth Alarms When set On the Depth alarms 1 2 3 activate at their respective set Depths during descent The audible will sound dur ing which time the Depth di...

Страница 42: ...42 OCL OPERATING MANUAL 2002 Design 2014 Doc No 12 5378 r01 4 9 15 REFERENCE...

Страница 43: ...Interface by installing the contact side of the watch first Removal should be the reverse order removing the contact side last The OCL must be in Watch Mode to interface with a PC or MAC computer The...

Страница 44: ...your original sales receipt and Warranty Registration Card Send freight prepaid and insured using a traceable method to the nearest Oceanic Regional Facility or to Oceanic USA If shipping to Oceanic U...

Страница 45: ...sealing O ring replacement is required each time the Battery is replaced Battery Installation NOTE The O ring must be a genuine Oceanic part available at an Authorized Oceanic Dealer Use of any other...

Страница 46: ...roviding corrected Depth and reduced No Deco and O2 Times at intervals of 1 000 feet 305 meters When the Conservative Factor is set On NDLs are calculated based upon the next higher 3 000 foot 915 met...

Страница 47: ...47 OCL OPERATING MANUAL 2002 Design 2014 Doc No 12 5378 r01 4 9 15 TECHNICAL DATA...

Страница 48: ...05 0 05 0 05 0 05 150 0 08 0 06 0 06 0 06 0 05 0 05 0 05 0 05 0 05 0 04 0 04 0 04 160 0 07 0 06 0 05 0 05 0 05 0 05 0 05 0 04 0 04 0 04 0 04 0 04 170 0 07 0 05 0 05 0 05 0 04 0 04 0 04 0 04 0 04 0 04...

Страница 49: ...3 0 03 0 03 0 03 180 0 05 0 04 0 04 0 04 0 03 0 03 0 03 0 03 0 03 0 03 0 03 0 03 190 0 04 0 04 0 04 0 03 0 03 0 03 0 03 0 03 0 03 0 03 0 03 0 00 Z BASED NDLS HR MIN METRIC Altitude 0 916 1221 1526 183...

Страница 50: ...mory and deletes the older dive Altitude Operational from sea level to 14 000 feet 4 270 meters elevation Measures ambient pressure every 30 minutes in Watch mode when Dive Computer mode is accessed a...

Страница 51: ...starting 10 min after the dive NUMERIC DISPLAYS Range Resolution NORM GAUG Modes Surface Interval 0 00 to 23 59 hr min 1 minute Dive No 0 to 24 1 Elapsed Dive Time 00 to 599 min 1 minute FO2 Set Poin...

Страница 52: ...www OceanicWorldwide com E mail hello oceanicusa com OCEANIC NORTHERN EUROPE Augsburg Germany Tel 49 0 821 810342 0 Fax 49 0 821 810342 29 Web www oceanic de E mail office oceanic de OCEANIC ITALY Gen...

Страница 53: ...53 OCL OPERATING MANUAL 2002 Design 2014 Doc No 12 5378 r01 4 9 15 OCL WATCH DIVE COMPUTER OPERATING MANUAL...

Отзывы: