Sauna & Steam

Oceanic Saunas  01902 450 550  sales

@oceanic-saunas.co.uk www.oceanic-saunas.co.uk

8

Sauna Heater Manual

No.

Description 

Function instruction

1

On/off button

Push to operate

2

Light button

Push to operate for sauna room light

3

Fan button

Push to operate for control box fan 

4

Setting button 

Preset time and temperature and the setting confirmation 

5

Increase button

 Press to increase 

6

Increase button

Press to decrease

7

Mode button

Change working mode

8

Time display 

Display working time or waiting time to work

9

Temp. display 

Display temperature

10

Light  LED

Indictor Led for sauna room lamp  

11

Model LED

Indictor LED for working mode, on mean under A model ,sauna heater is 

working  

12

Wait  LED

Indicator LE D for working mode, on mean under B  waiting to work 

13

Sauna room 

Door(interlock) 

indicator LED

indicator LED is on: the sauna heater stop working ,there is control signal 

to control box main circuit board when the door is open , the default is the 

connection switch is downward (opposite side of ON), when the door is open , 

there is on signal to circuit board , the LED is on and sauna heater stop work.

Such as on sauna room door install a switch connect to circuit board , the switch 

‘s on or off signal can control sauna heater work or stop. when you need the 

switch send off signal to working , the default is ok, when you need the sauna 

heater under the on signal to work , just push the switch circuit board  to  “on” 

side” 

14

High temperature LED 

indicator LED is on , sauna heater stop work . the sauna room temperature 

higher then 120 centigrade . high temperature cut off switch works, when the 

temperature in sauna room down to 100 centigrade , and find out the high 

temperature problem then preset the switch by hand 

15

Fan LED

Press to operate for fan

16

Heating LED

On means the heat element is working 

17

Stop working LED

indicator LED for stop working , the sauna room temperature exceed the preset 

temperature , the heat element pause(when temperature 2 centigrade lower 

than preset temperature ,sauna heater will work again, 

Chart 5. Keys and LED instruction

Содержание 0CS090B

Страница 1: ...RODUCT IMAGE Oceanic Ltd Pountney Street Wolverhampton WV2 4HX Phone 01902 450 550 sales oceanic saunas co uk www oceanic saunas co uk Sauna Steam HEAVY DUTY SAUNA HEATER Assembly and operating manual...

Страница 2: ...Temperature Sensor 8 6 1 Parts Description 8 6 2 Temperature Sensor Parameters 8 7 Installation 9 7 1 Minimum Clearances 10 7 2 Installation for sauna heater 11 7 3 Installation for controller 11 7 4...

Страница 3: ...Risk of fire Do not operate sauna heater without sauna stone Do not touch the heater when operational as it is very hot When this heater is used in an unsupervised and or public location with the adva...

Страница 4: ...1 5 40 50 L 480 W 560 H 660 0CS105B 10 5 3 1 5 H1 H3 H5 3 2 0 H2 H4 H6 9 15 400 3N Terminal1 5 1 5 Terminal2 5 1 5 40 50 0CS120B 12 0 6 2 0 H1 H6 10 18 400 3N Terminal1 5 2 5 Terminal2 5 2 5 40 50 0CS...

Страница 5: ...agram for sauna heater and control Box i Sauna heater circuit diagram OC SA I 230V 230V 3 4 248 217 78 OC SA II 230V 400V 230V 400V 4 5 9 280 217 78 Model Input Output Load power Size mm 3N 3N Kw L W...

Страница 6: ...ntroller AC400V 3N 50 60Hz OCS B Control box circuit diagram Terminal 1 Voltage DC5V Fan AC230VAC230V Max Output Power 12kw Max Output Power 12kw Light Terminal 2 W W V V U U N N L N F N L3 L2 L1 N Te...

Страница 7: ...tions 7 1 Sauna heater frame and parts No parts description 1 Heat element heating 2 Shell Insulate the inner shell to prevent from scalding 3 Cover Panel Cover the electrical parts 4 terminal Connect...

Страница 8: ...he door is open the default is the connection switch is downward opposite side of ON when the door is open there is on signal to circuit board the LED is on and sauna heater stop work Such as on sauna...

Страница 9: ...n Function instruction 1 Wire anchorage Route of wire entry and fasten wires 2 terminal Connect to the power supply 3 Terminal Connect to heater 4 Heater light and fan output Outlet of wires to heater...

Страница 10: ...ven in Fig 7 and chart 8 and allow for safety and convenience Is the controller special electrical box suitable for the heater power and control requirements Choose the cable wire according to table 1...

Страница 11: ...B min Model Safety Distance mm A B C D E min max min min min min OCS090B 120 220 100 200 1200 630 OCS120B 120 220 100 200 1200 630 OCS150B 160 260 100 200 1200 630 8 2 Installation of sauna heater Re...

Страница 12: ...hould be installed at a height of approximately 1200mm for ease of use Installation method Drill a 40mm diameter hole through the wall Pull the front off the keypad you may find it easier with a small...

Страница 13: ...re sensor i Install the temperature sensor as in the diagram opposite ii Open the cover with a screwdriver iii Fix the bottom of the temperature sensor on to wall with screw iv Replace the cover OC SB...

Страница 14: ...ace around the heater by drilling screwing accordingly Note It is important that the top rail of the guard is set at least 30 mm below the rim of the heater such that it does not receive heat radiatio...

Страница 15: ...at least 20mm air slot between moisture proof Aluminum foil and inside panel iv Leave a slot between wall panel and ceiling to prevent gathering vapor 8 10 10 Air ventilation of sauna room Mix the col...

Страница 16: ...g and bathing the sauna room can also be dried by leaving the door open after bathing 5 If there is only an exhaust vent in washing room leave an opening MIN CM Under the sauna door Mechanical ventila...

Страница 17: ...ant the sauna to start heating up half way through so its ready at the end of the film you can use the B model setting which can be set if you press the MENU ENTER and the time window will display 4 0...

Страница 18: ...If the power supply indicator LED L1 red is on check the wire 2 Change the controller The controller is on but the sauna heater doesn t work 1 The sauna heater hasn t been connected 2 There is a prob...

Страница 19: ...le is broken 2 The temperature is lower than 0o C 3 The temperature is higher than 115o C 1 Lo C means temperature sensor hasn t connected or the temperature is lower than 0o C check the connection ca...

Страница 20: ...repair For commercial users we recommend these inspections be conducted on a monthly basis by a member of the maintenance staff and detailed records kept For domestic use these checks should be carri...