background image

INTRODUCTION

1

2 of 12

The Oceanic Systems NMEA2000® 3420 AC Monitor is designed to monitor any AC source 

including single-phase (phase A), single-phase (phase A,B), and three-phase (phase A,B,C)

This unit is designed to operate in a protected marine environment such as an engine room. It is 

very important that it is installed and set up correctly according to this manual. Please read and 

follow the installation and setup instructions carefully to achieve the best results.

1.2 PRODUCT FEATURES

The NMEA2000® 3420 AC Monitor has the following features:

 

 

● Inputs from AC voltage (Max 280 VAC), 200 Amp AC Current    

 

   Transformer

 

● User Settable Device Instance using rotary switches

 

● User Settable Circuit Type

 

● Heartbeat blue LED confirming NMEA transmission.

 

● NMEA2000® micro C interface plug

 

● Panel or DIN rail mounting option

 

● The unit reports AC Voltage, Current, Power, Frequency.

Содержание NMEA2000 3420

Страница 1: ...NMEA2000 AC MONITOR Part Numbers 3420 USER MANUAL Revision 2 00 ...

Страница 2: ......

Страница 3: ...Unpacking the box 3 2 2 Mounting the unit 3 2 3 Connecting the NMEA2000 Cable 3 2 4 Connecting the sensor cables to the WAGO socket 4 2 5 AC Monitor Connections 5 3 Configuration 6 3 1 Configuring Circuit Type 6 3 2 Device Instance 9 4 Warranty 11 5 Technical Support 12 ...

Страница 4: ... up correctly according to this manual Please read and follow the installation and setup instructions carefully to achieve the best results 1 2 PRODUCT FEATURES The NMEA2000 3420 AC Monitor has the following features Inputs from AC voltage Max 280 VAC 200 Amp AC Current Transformer User Settable Device Instance using rotary switches User Settable Circuit Type Heartbeat blue LED confirming NMEA tra...

Страница 5: ...cations are shown on the following drawing Note Mount away from sources of condensation and moisture 2 3 CONNECTING THE NMEA2000 CABLE The unit is connected to the NMEA2000 network by the 5 way micro C socket on the front Carefully attach the network drop cable to this plug and hand tighten until it it is fully seated Take care to match the orientation of the pip inside the socket to the recess in...

Страница 6: ...ED ELECTRONICS ENGINEER ONLY The cables from the power source to the external sockets are connected using the 6 x 2way WAGO Cage Clamp terminal block The wire should be stripped for 8mm and then the cage clamp opened with a small screwdriver in the slot above the wire connection Then simply insert the wire into it s connection slot and release the cage clamp by removing the small screw driver This...

Страница 7: ... Terminal 3 Current Transformer Phase C 2 Terminal 4 Voltage Phase A Line Fit in line 3 Amp fuse Terminal 5 Voltage Phase B Line Fit in line 3 Amp fuse Terminal 6 Voltage Phase C Line Fit in line 3 Amp fuse Terminal 7 Current Transformer Phase A 1 Terminal 8 Current Transformer Phase B 1 Terminal 9 Current Transformer Phase C 1 Terminal 10 No Connection Terminal 11 Neutral Terminal 12 No Connectio...

Страница 8: ...e set up When turning on the AC monitor for the first time the blue LED will flash quickly to indicate it s not set up The AC Monitor is set up by turning the small rotary switch with a small screw driver to the required setting and then pressing the button for 5 seconds Be sure to return the switch to the correct instance setting afterwards Note You can always change the set up of the AC monitor ...

Страница 9: ...7 of 12 Two Phase Connection ...

Страница 10: ...8 of 12 Three Phase Connection ...

Страница 11: ...etup Note The frequency values on PGNs PGN127747 PGN127748 and PGN127749 are the same as the system frequency They are not measured on each phase separately Note The power values on PGNs PGN127744 PGN127745 and PGN127746 are calculated from the measured voltage and current values P U I Type PGN No PGN Name Monitor PGN127744 AC Power Current Phase A PGN127745 AC Power Current Phase B PGN127746 AC P...

Страница 12: ...efinately Load Dump Protection Yes SAE J1113 Size mm 96 x 84 x 35 Weight gr 120 Parameter Value IEC 60954 Classification Protected Degree of Protection IP40 Operating Temperature 25 C to 50 C Storage Temperature 40 C to 70 C Relative Humidity 93 RH 40 per IEC60945 8 2 Vibration 2 13 2Hz 1mm 13 2 100Hz 7m s2 per IEC 60945 8 7 Electromagnetic Emission Conducted and Radiated Emission per IEC 60945 9 ...

Страница 13: ...UENTIAL DAMAGES DAMAGES FOR LOSS OF USE LOSS OF ANTICIPATED PROFITS OR SAVINGS OR ANY OTHER LOSS INCURRED BECAUSE OF INTERRUPTION OF SERVICE IN NO EVENT SHALL OCEANIC SYSTEMS AGGREGATE LIABILITY EXCEED THE PURCHASE PRICE OF THE PRODUCT S INVOLVED OCEANIC SYSTEMS SHALL NOT BE SUBJECT TO ANY OTHER OBLIGATIONS OR LIABILITIES WHETHER ARISING OUT OF BREACH OF CONTRACT OR WARRANTY TORT INCLUDING NEGLIGE...

Страница 14: ...ve New Milton Hampshire BH25 6RH United Kingdom Tel UK 44 0 1425 610022 Tel USA 844 898 6462 Fax 44 0 1425 614794 Email sales osukl com Web www osukl com Copyright 2019 Oceanic Systems UK Ltd All rights reserved Our policy is one of continuous product improvement so product specifications are subject to change without notice Oceanic Systems products are designed to be accurate and reliable However...

Отзывы: