2.4 CONNECTING THE SENSOR CABLES TO THE WAGO SOCKET
WARNING: Risk of Electric Shock
This device contains potentially hazardous voltages. Ensure that power is removed from all AC
circuit that will be connected to the AC monitor. Do not attempt to disassemble the device.
This device contains no user serviceable parts. Connecting the AC monitor must be performed
by QUALIFIED ELECTRONICS ENGINEER ONLY.
The cables from the power-source to the external sockets are connected using the 6 x 2way
WAGO Cage Clamp terminal block. The wire should be stripped for 8mm and then the cage
clamp opened with a small screwdriver in the slot above the wire connection. Then simply
insert the wire into it’s connection slot and release the cage clamp by removing the small screw
driver. This will produce a secure gas tight connection on wire sizes from 0.08 – 2.5 mm²
The terminal connections are numbered as follows:
1
2
3
4
5
6
7
8
9 10 11 12
1
2
3
4
5
6
7
8
9 10 11 12