background image

CABINET

 

The OWC1811QC cabinet is constructed of 18 gauge steel with a gray and blue polyester 

powder coated finish that will compliment any decor. The entire cabinet is insulated with 

sound-absorbing insulation for cool, quiet comfort.  All units come equipped with swivel 

casters for portability and convenient set-up. 

 

DELUXE ELECTRONIC CONTROLLER 

The OWC1811QC is equipped with a deluxe electronic controller.  When proper power is  

connected to the unit, the thermostat will control the unit to cool a space to the desired  

temperature.  The thermostat is also capable of controlling the fan to operate automatically 

(when needed) or continuously.  To protect the compressor from short-cycling, there is a 

built-in time delay in the thermostat.  In the event of a power outage, all thermostat  

settings are saved, and the unit will re-start automatically. 

 

FAN SPEED CONTROL 

The deluxe electronic controller is capable of setting the fan speed for manual or  

automatic.  In manual setting, the fan speed can be programmed to any of the six fan speed 

levels, from (1) Low to (6) High.  In auto setting, the unit will determine the best fan speed 

based on the inside temperature and selected SETPOINT. 

 

CONDITION ALARM

CON 

The LED thermostat of the unit will display the fault “CON” which indicates a condition that 

needs to be addressed. 

 

CONDENSATE PUMP… Failed/Restricted drain tube/routed incorrectly

 

 

WATER SUPPLY……….. Turned off/Interrupted flow

 

                              

EITHER CONDITION WILL DISABLE THE COMPRESSOR 

 

CONDENSATE PUMP 

Each OWC1811QC unit comes equipped with an Automatic Condensate Pump that  removes 
the condensate.  The pump discharges through a check valve located on top of the conden-

sate pump assembly. The vinyl tubing exits through a ¼” male quick connect fitting, located 
in the recessed area on the right side of the unit. The pump has capabilities up to a 20’ lift, 

to handle almost any installation requirement.  If a failure occurs with the operation of the 
pump circuit, the 

Normally Closed overflow switch

 

will open, and the fault “CON” will dis-

play in the window. When the failure has been corrected, or the condensate line blockage/
kink has been resolved, the fault will be dropped from the screen, and the unit will restart.

 

HIGH PRESSURE SAFETY SWITCH 

Located in the recessed area of the OWC1811QC unit is a manual reset high pressure switch. 
It is used for the protection of the compressor, in the event that the condenser water supply 
is turned off.  If the internal pressure exceeds the limit setting, the switch cycles off the 
compressor, while the evaporator fan continues to operate. Once the water interruption has 
been corrected, turn the unit off, 

RESET THE RED BUTTON

 by pushing down on the rubber 

boot in the recessed area of the unit, listening for the click, and restart the unit.

 

FILTERS 

The OWC unit is equipped with a washable filter at the air intake. An electrostatic mesh air 

filter is located behind the evaporator return air grille to filter the air before it is cooled,  

keeping the coil free from dust build-up.  The filter can be easily removed and cleaned. 

 

POWER CORD 

The OWC1811QC unit is equipped with a 10 foot (5-15P) power cord for convenience, and has 

a LCDI device for added safety.  

STANDARD FEATURES 

Содержание OWC1811QC

Страница 1: ...ENGINEERING INSTALLATION AND SERVICE MANUAL OWC1811QC 1 5 Ton Deluxe Portable Water Cooled Spot Cooler With Quick Connect EISM OWC1811QC 05012022...

Страница 2: ...In our ongoing process of continuous improvement the items and procedures described in this manual are subject to change without notice Please note model and serial number of the OWC1811QC unit when...

Страница 3: ...ected to the proper source of electrical power the OWC1811QC is controlled by a solid state electronic device with numerous op tions of temperature and airflow controls that will provide the desired l...

Страница 4: ...NNECT FITTING 1 4 LIFT VERTICAL 20 FT REFRIGERANT 18 oz R 410A HEIGHT 45 7 in WIDTH 21 5 in DEPTH 16 0 in NET WEIGHT 155 lb SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Cooling capacity is total BT...

Страница 5: ...unit comes equipped with an Automatic Condensate Pump that removes the condensate The pump discharges through a check valve located on top of the conden sate pump assembly The vinyl tubing exits thro...

Страница 6: ...ed where it is needed A nozzle kit can be used to improve the velocity ROOM AIR CONDITIONER One feature of the OWC1811QC is it operates as a room air conditioner because water is used as the means for...

Страница 7: ...IOR Cubby for the Hose Kit High Pressure Switch Reset Button Drain Water In Electrical Cord Strain Relief Water Out Condensate Pump Access Door Condensate Pump Motor Thermostat Compressor Evaporator C...

Страница 8: ...on the back of the unit to confirm the proper power is available for the unit Refer to Specifications section for voltage and amperage requirements For the proper NEMA receptacle refer to Electrical s...

Страница 9: ...nclude edge guards By removing the OWC1811QC discharge grille the nozzle kit can then be installed in the grille opening Evaporator return air plenum is available for installations where it is require...

Страница 10: ...ening 2DDA 10 for OWC1811QC converts the evaporator discharge to a 10 inch diameter round duct When used in conjunction with the evapo rator return air plenum 2DEP 12 the unit can provide closed loop...

Страница 11: ...scharge to a drain A QC lanyard is supplied with each QC Coupling When engaged this device releas es the internal valve of the coupling allowing for air to break the vacuum and drain the hose All Hose...

Страница 12: ...ing 2 Connect WATER IN hose to water supply using hose connection and sink adapter if needed 3 Install WATER OUT line in drain allowing for free drain conditions with an air space around the opening 4...

Страница 13: ...stallation of a QC water cooled unit where the Standard QC Hose Kit cannot accommodate the installation The kit provides a means of connecting hoses to a QC Model unit when the water source and drain...

Страница 14: ...ever comes first This cycle repeats every four hours FAN SPEED The operator can select between AUTO or MANUAL fan speed control Pressing the FAN SPEED button will switch speed from AUTO to MANUAL In...

Страница 15: ...peed Limit Setting 30 55 P4 Temperature Sensor Calibration 10 P10 Temperature Display F or C P13 Supply Fan Operation Cycling or Continuous P1 P2 To adjust fan speed settings P1 represents the high fa...

Страница 16: ...742 hours 6 Add the 2 number sets together to get total hours 03 and 486 3486 hours 01 and 59 1059 hours TOTAL HOURS REPRESENTS COMPRESSOR RUN TIME MODEL CODE SETTINGS OWC1811QC P1 80 P2 50 OWC PROGRA...

Страница 17: ...n and close causing a harmonic pitch in the water supply line In these cases it is recommended that the water valve be adjusted 1 Disconnect the unit power 2 Remove water valve cover plate or back pan...

Страница 18: ...w controller and secure in place C POWER MODULE To remove the power module remove the rear control box cover Disconnect wires one at a time and re attach each wire while holding replacement module in...

Страница 19: ...NOT START CAUSE Thermostat set point is too high REMEDY Make sure set point is lower than room temperature Look for a red dot to the right of the temperature displayed for cooling Note there is a time...

Страница 20: ...en servicing pump follow these steps 1 Make certain that the unit is disconnected from the power source before attempting to service or remove any component 2 Be sure the floats move freely Clean as n...

Страница 21: ...PIPING SCHEMATIC 19...

Страница 22: ...WIRING SCHEMATIC FOR OWC1811QC 20...

Страница 23: ...ten instructions or has been altered or modified in any way b Product that has been subjected to any abnormal power conditions such as loss of power power surges voltage irregularities such as brown o...

Страница 24: ...___________________________ Purchased from _______________________________ Date Installed _________________________________ For Technical Support or service parts contact our Keep Cool Team at 847 583...