ALPHA-PR0 X-DIVERS rel. 1.3
13
#UNDER
W
ATERNA
TURALL
Y
7 - TROUBLESHOOTING
Problem
Probable cause
What to do
The surface
unit does not
turn on
1. Low battery
1. Recharge the batteries
The
underwater
unit does not
receive
1.
Power turned off
2. The surface diver cable
is not attached to the
surface unit
3. Low volume
4. Flooded underwater unit
1. Turn on the surface unit
2. Check the surface unit
connection
3. Turn up volume
4. Return to surface, rinse in fresh
water and send to OCEAN
REEF service center
Surface is not
receiving
1.
Volume too low
2.
Power turned off
3. Flooded microphone on
underwater unit
4.
Flooded UW unit
1. Raise volume on the surface
audio and check the power
2. Turn on the surface unit
3. Return to surface, rinse in fresh
water, replace mic
4. Return to surface, rinse in fresh
water and send to OCEAN
REEF service center
Recall system
1. Issues with the
underwater unit button
2. Issues with the surface
unit alarm system
1. Return to surface, rinse in fresh
water and send to to OCEAN
REEF service center
2. Return to surface and send to
OCEAN REEF service center
Replacing the Mic
Remove the MIC assembly from the mask, unscrew few threads of the two little side screws
and pull off the Mic. Replace with the new one being careful not to overtighten the little
screws to avoid damages to the contacts and to mount the microphone in the same direction.