3.1 Calibrate the EFI controller

Introduction

The external controller is either an EFI (IC303/IC305/IC408), a Creo (IC304/IC304Plus)
or an Océ PRISMAsync controller. This procedure describes the calibration of the EFI
controller. In case of an IC408 controller you must use CWS on a remote PC. Before
you can calibrate the EFI controller you must print the calibration chart.

Print the calibration chart

1.

From 'Command Workstation', click 'Server' - 'Manage color...'.

2.

Click 'Calibrator'.

[1] Calibrator button

3.

Select or check the measurement method.

[2] Measurement method selection list

Chapter 3 - Controller calibration

12

3.1 Calibrate the EFI controller

Содержание CS550 Pro

Страница 1: ...o Oc CS550 CS6xx Pro Calibration Oc User Manual...

Страница 2: ...makes no representation or warranties with respect to the contents hereof and specifi cally disclaims any implied warranties of merchantability or fitness for any particular purpose Further Oc reserve...

Страница 3: ...ibrate the EFI controller 12 3 1 Calibrate the Creo controller 17 3 1 Calibrate the Oc PRISMAsync controller 20 3 2 Check the print quality 28 Chapter 4 Printer calibration 29 4 1 Perform the adjustme...

Страница 4: ...4 Contents...

Страница 5: ...Chapter 1 Introduction o...

Страница 6: ...eo controller IC304 IC304 Plus default including a photo spectrometer Fiery X3e TY2 65C KM embedded controller IC408 for which a photo spectrom eter is optional Oc PRISMAsync controller Oc CS655 and O...

Страница 7: ...ments In normal circumstances there is no need to do additional calibrations External circumstances for example temperature humidity and consumables change over time These changes effect the colour re...

Страница 8: ...int quality still does not meet your requirements you can consider to proceed with the printer calibration 4 1 Perform the adjustment operation on page 30 1 3 Calibrate the printer 4 2 Adjust the whit...

Страница 9: ...Chapter 2 Check the print quality o...

Страница 10: ...d the A3 Tabloid reference media with the correct paper settings Note Reference media is the media that you use mostly bulk The Oc reference media is Oc Top Color 90 g m2 Warm up the printer 1 Print t...

Страница 11: ...Chapter 3 Controller calibration o...

Страница 12: ...oller In case of an IC408 controller you must use CWS on a remote PC Before you can calibrate the EFI controller you must print the calibration chart Print the calibration chart 1 From Command Worksta...

Страница 13: ...d patches for A3 Tabloid recommended Select 21 Sorted Patches for A4 Letter At Paper Size select the setting according to the previous step At Input tray select the tray that contains the selected pap...

Страница 14: ...o close the information window Result The printer performs an automatic calibration adjustment and prints the sorted patches chart Calibrate the EFI controller 1 Click Measure to start the calibration...

Страница 15: ...per colour Position the spectrometer at the blinking red cross above the column with coloured patches Hold down the spectrometer button and wait for the beep Scan the column with patches slowly 9 Mea...

Страница 16: ...2 Calibration successful 8 To calibrate per media return to step 3 of the Print the patches chart Note Follow both the above procedures per screen you use Result The EFI controller is calibrated Chapt...

Страница 17: ...alibrate the Creo controller 1 Click Tools Calibration The Color Calibration window opens 2 Print the calibration chart At Tray select the location of the media you use mostly At Media Type define the...

Страница 18: ...in the Color Calibration window to perform the measurement 14 Measurement instructions 4 Click Next after successful calibration 15 Calibration successful Chapter 3 Controller calibration 18 3 1 Cali...

Страница 19: ...a selection window 6 Click Finish 7 Return to step 2 to calibrate other media you use Note Follow the above procedure per screen you use Result The Creo controller is calibrated Chapter 3 Controller c...

Страница 20: ...n of the Oc PRISMAsync controller At the beginning of the procedure you print a calibration chart that is used to calibrate the Oc PRISMAsync controller Print a calibration chart 1 From the System vie...

Страница 21: ...edia families The list of halftones for the selected media family appears 3 Press the required halftone and press OK 19 Halftones The list of media for the selected media family appears Chapter 3 Cont...

Страница 22: ...alibration view appears 5 Press Print calibration chart 21 Calibration view The printer is now adjusting 6 Please wait and check the progress at the upper left corner of the operator panel Chapter 3 C...

Страница 23: ...for the selected media family halftone and media Calibrate the Oc PRISMAsync controller 1 Press Calibrate meter and follow the instructions 22 Calibrate meter option Chapter 3 Controller calibration...

Страница 24: ...te i1 meter in the holder Press the button of the meter Please wait until the meter is calibrated 3 Put 4 sheets of the same media as the calibration chart under the calibration chart Chapter 3 Contro...

Страница 25: ...ton of the meter until you hear a beep Move the meter across the row of patches Release the button of the meter If the scan failed select the current colour again on the operator panel and repeat the...

Страница 26: ...he calibration view 25 Calibration view with succeeded scans 6 Press Yes to save and apply the calibration 26 Calibration confirmation window Chapter 3 Controller calibration 26 3 1 Calibrate the Oc P...

Страница 27: ...re for another media family Press No to stop the calibration procedure Result The controller is calibrated for the selected media family halftone and media Repeat the calibration for every media famil...

Страница 28: ...ence Chart pdf Result The result of the controller calibration as checked normally meets the required print quality If the print quality still does not meet your requirements you can consider to proce...

Страница 29: ...Chapter 4 Printer calibration o...

Страница 30: ...t Perform the adjustment operation 1 Select the following buttons to open the Expert Adjustment Menu Utility counter key 03 Machine Admin Setting 01 System Setting 05 Expert Adjustment 2 Select 08 Exe...

Страница 31: ...Adjustment item 4 Select Exit to start the automatic adjustment 30 Expert Adjustment Menu The Machine screen opens and displays Now adjusting Chapter 4 Printer calibration 31 4 1 Perform the adjustme...

Страница 32: ...Result The automatic adjustment takes approximately 4 minutes The machine displays Ready to print when the adjustment is completed Chapter 4 Printer calibration 32 4 1 Perform the adjustment operation...

Страница 33: ...elect the following buttons to open the Expert Adjustment Menu Utility counter key 03 Machine Admin Setting 01 System Setting 05 Expert Adjustment 2 Select 07 Quality Adjustment 31 Expert Adjustment M...

Страница 34: ...wing buttons to print the gamma calibration chart Next and Previous to define the required screening The default is Dot1 Adj data reset to set the gamma offset values to zero Readjust to re adjust the...

Страница 35: ...ess the green Start key Result A printed test chart to set the gamma offset values automatically Set the gamma offset values automatically 1 Place the printed test chart on the scanner face down with...

Страница 36: ...tomatically New values are used to print a new test chart 4 Check the calibration status message at the upper left If the message is Touch COPY to output a chart do the following Select Copy Press the...

Страница 37: ...l the message is Completed normally 35 Calibration status message If the message is Completed normally the printer is adjusted properly 36 Calibration status message Chapter 4 Printer calibration 37 4...

Страница 38: ...Result Now the white point of the printer is adjusted Chapter 4 Printer calibration 38 4 2 Adjust the white point gamma offset...

Страница 39: ...roller In case of an IC408 controller you must use CWS on a remote PC Before you can calibrate the EFI controller you must print the calibration chart Print the calibration chart 1 From Command Workst...

Страница 40: ...ted patches for A3 Tabloid recommended Select 21 Sorted Patches for A4 Letter At Paper Size select the setting according to the previous step At Input tray select the tray that contains the selected p...

Страница 41: ...to close the information window Result The printer performs an automatic calibration adjustment and prints the sorted patches chart Calibrate the EFI controller 1 Click Measure to start the calibratio...

Страница 42: ...ns per colour Position the spectrometer at the blinking red cross above the column with coloured patches Hold down the spectrometer button and wait for the beep Scan the column with patches slowly 45...

Страница 43: ...48 Calibration successful 8 To calibrate per media return to step 3 of the Print the patches chart Note Follow both the above procedures per screen you use Result The EFI controller is calibrated Cha...

Страница 44: ...Calibrate the Creo controller 1 Click Tools Calibration The Color Calibration window opens 2 Print the calibration chart At Tray select the location of the media you use mostly At Media Type define t...

Страница 45: ...s in the Color Calibration window to perform the measurement 50 Measurement instructions 4 Click Next after successful calibration 51 Calibration successful Chapter 4 Printer calibration 45 4 3 Calibr...

Страница 46: ...ia selection window 6 Click Finish 7 Return to step 2 to calibrate other media you use Note Follow the above procedure per screen you use Result The Creo controller is calibrated Chapter 4 Printer cal...

Страница 47: ...ion of the Oc PRISMAsync controller At the beginning of the procedure you print a calibration chart that is used to calibrate the Oc PRISMAsync controller Print a calibration chart 1 From the System v...

Страница 48: ...Media families The list of halftones for the selected media family appears 3 Press the required halftone and press OK 55 Halftones The list of media for the selected media family appears Chapter 4 Pri...

Страница 49: ...calibration view appears 5 Press Print calibration chart 57 Calibration view The printer is now adjusting 6 Please wait and check the progress at the upper left corner of the operator panel Chapter 4...

Страница 50: ...t for the selected media family halftone and media Calibrate the Oc PRISMAsync controller 1 Press Calibrate meter and follow the instructions 58 Calibrate meter option Chapter 4 Printer calibration 50...

Страница 51: ...Rite i1 meter in the holder Press the button of the meter Please wait until the meter is calibrated 3 Put 4 sheets of the same media as the calibration chart under the calibration chart Chapter 4 Prin...

Страница 52: ...tton of the meter until you hear a beep Move the meter across the row of patches Release the button of the meter If the scan failed select the current colour again on the operator panel and repeat the...

Страница 53: ...the calibration view 61 Calibration view with succeeded scans 6 Press Yes to save and apply the calibration 62 Calibration confirmation window Chapter 4 Printer calibration 53 4 3 Calibrate the Oc PR...

Страница 54: ...ure for another media family Press No to stop the calibration procedure Result The controller is calibrated for the selected media family halftone and media Repeat the calibration for every media fami...

Страница 55: ...print the Oc Colour Reference chart to check the print quality Print the Oc Color Reference chart 1 Print the file Oc Color Reference Chart pdf Result A printed Oc color reference chart to evaluate t...

Страница 56: ...troller 20 47 why 7 Color reference chart Color reference chart 10 Configuration Configuration 6 G Gamma offset Gamma offset 33 P Print quality Print quality 10 after controller calibration 28 after p...

Отзывы: