Set the device address DIP switches 1 through 8 using the following table. Each device on the RS-485 network must have a
different address. You can configure up to 256 devices (address 0 .. 255) on the RS-485 network. When the switch is pushed
up (see the drawing above) it is ON.
Table 1. DIP address switch settings
Dome Address
SW1 (address) switch number
1
2
3
4
5
6
7
8
0
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
1
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
2
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
3
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
4
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
5
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
6
OFF
ON
ON
OFF
OFF
OFF
OFF
OFF
…
…
…
…
…
…
…
…
…
255
ON
ON
ON
ON
ON
ON
ON
ON
6.
Set the network baud rate DIP switches 1 and 2 using the following table. Each device on the RS-485 network must use the
same baud rate. By default, the baud rate is set to 2400 baud (1
g
OFF, 2
g
OFF).
Baud rate
SW2 switches
1
2
2400
OFF
OFF
4800
ON
OFF
9600
OFF
ON
19200
ON
ON
7.
Ensure that the camera lens and the inside of the lower dome is clean, then reinstall the lower dome. Position the dome onto
the back box, then tighten the two lock screws.
NOTE
Do not put the protective foam back inside the dome. Save the foam and other packaging for possible use at a later time.
SECTION 2: INSTALLATION