OBID
i-
scan
®
HF
Installation
ID ISC.ANT1800/700-A/-B
FEIG ELECTRONIC GmbH
Seite 63 von 71
M00910-8e-ID-B.doc
Ambient Conditions
Temperature range
– Operating
– Storage
–25 °C to +50 °C
–25 °C to +70 °C
Applicable Standards
RF approval
– Europe
– USA
- Canada
EN 300 330
FCC Part 15
RSS 210
EMC
EN 301 489
Safety
– Low Voltage Directive
– Human Exposure
EN 60950-1
EN 50364
* Persistent deformation after load release approx. 3 cm.
** Qty. 2 ID ISC.ANT1800/700-A/-B antennas, antenna spacing (antenna center), same flow direc-
tion, Tag 46 mm x 75 mm ISO15693, sensitivity / minimum field strength H
min
=60 / 40 mA/m rms,
transmitting power 8 W, tag orientation parallel to antenna for horizontal movement through the
antenna. The maximum antenna distance also depending of the strength of the Transponder an-
swer signal! Z.B NXP I-Code SLi-X / NXP I-Code SLi-S
*** Tag 46 mm x 75 mm ISO 15693, sensitivity / minimum field strength H
min
=60 / 40 mA/m rms,
transmitting power 8 W, aligned in all 3 dimensions for horizontal movement through the antenna.
The maximum antenna distance also depending of the strength of the Transponder answer signal!
Z.B NXP I-Code SLi / NXP I-Code SLi-S