OBID
i-
scan
®
HF
Installation
ID ISC.ANT1800/700-A/-B
FEIG ELECTRONIC GmbH
Seite 40 von 71
M00910-8e-ID-B.doc
Reading a Serial Number
Step
Action
Note
1
Attach a tag to an antenna
Here to antenna at multip-
lexer output 1
Use adhesive tape, for example
2
Activate antenna 1 with
command: „Function Unit
Commands -
Multiplexer“
Parameter:
„Channel Select“
„Cascade Level = 1“
„Output Channel of
Input 1 = 1“
3
Confirm with “Send”
4
Select „Test and
Measurement“
5
Select „ISO Inventory“
function and activate by
clicking on „Start“.
The serial number and tag
type will be shown in the
display.
6
Repeat Step 1 to 5 for
every further antenna