Installing the Antenna Base and Antenna Body
The antenna will be mounted on the floor. Please note, the antenna conductors in the middle of the
antenna body have to have the same direction
). Afterwards, the antenna has to be aligned
the antenna vertically, by using the adjusting screws (
).
Please read also
function of Gate People Counter
0 Project Notes People Counter (GPC).
Fig. 8 Conductors shape have to have same direction
Adjusting screws (hexagon socket width AF 4)