DIP switch 

Modbus Address 

on 

off 

off 

off 

Address 01 

off 

on 

off 

off 

Address 02 

on 

on 

off 

off 

Address 03 

off 

off 

on 

off 

Address 04 

on 

off 

on 

off 

Address 05 

off 

on 

on 

off 

Address 06 

on 

on 

on 

off 

Address 07 

off 

off 

off 

on 

Address 08 

on 

off 

off 

on 

Address 09 

off 

on 

off 

on 

Address 10 

on 

on 

off 

on 

Address 11 

off 

off 

on 

on 

Address 12 

on 

off 

on 

on 

Address 13 

off 

on 

on 

on 

Address 14 

on 

on 

on 

on 

Address 15 

 
RS-485 bus should be terminated with on-board 120 ohm resistors by turning on the termination DIP switch 
on both ends of the communications bus. 

4.4  Test mode 

To enter test mode, set DIP7 and DIP8 on and all other DIPs off. The light will enter test mode when power 
is turned on. To leave the test mode, turn off DIP7 and DIP8 and turn off the power.

 

 

DIP switch 

Test mode 

on 

on 

Test mode enabled. All other DIPs off. 

off 

off 

Test mode disabled. 

 
Light mode is selected with DIPs 1-2. There is normally a delay when changing time-of-day modes (day, 
twilight and night) based on photocell data. Using accelerated photocell mode will decrease the delay to a 
minimum. 

DIP switch 

Light mode 

off 

off 

Accelerated photocell light behavior 

on 

off 

RED light only 

off 

on 

IR light only 

on 

on 

Reserved 

 
Flashing rate is selected with DIPs 4-5. 

DIP switch 

Flash rate (FPM) 

off 

off 

Steady 

on 

off 

20 

off 

on 

40 

on 

on 

60 

 
 
 
 
 
 
 
 
 

Содержание Medium-Intensity 2000cd compact Series

Страница 1: ...Obelux Medium Intensity 2000cd compact series manual Medium intensity 2 000cd red aviation obstruction light ICAO Medium Intensity Type B C FAA L 864 L 885 NVG Compliant Infrared 850nm...

Страница 2: ...ALLATION 10 3 1 DEVICE INSTALLATION 10 3 2 WIRING 10 3 2 1 Mains In Out AC versions 11 3 2 2 DC In Out DC versions 11 3 2 3 Modbus RS 485 In Out 11 3 2 4 Alarm Relay Output 11 3 2 5 Chaining Lights 12...

Страница 3: ...Author 0 1 02 01 2020 Document created JSi 1 0 19 05 2020 Release JSi 1 1 05 10 2020 Updated product codes heater JSi Acronyms and Abbreviations FAA Federal Aviation Administration FPM Flashes Per Mi...

Страница 4: ...s Yes Yes Yes No MI ICAO AC 2KR IR X 10 2 000 200 cd Type B C 100 240VAC Yes Yes Yes Yes Yes Yes MI ICAO DC 2KR IR B 10 2 000 200 cd Type B C 10 60VDC No Yes Yes Yes Yes No MI ICAO DC1224 2KR IR X 10...

Страница 5: ...5 100 240VAC Yes Yes Yes Yes Yes MI FAA DC 2KR IR B 10 2 000cd L 864 L 885 10 60VDC No Yes Yes Yes No MI FAA DC 2KR IR X 10 2 000cd L 864 L 885 10 60VDC Yes Yes Yes Yes Yes B 10 B basic model X 10 IO...

Страница 6: ...notice 1 3 Product highlights Figure 1 Main functional parts of light head 1 Location of photocell and GPS do not cover 2 Spirit level 3 Location of cable glands M20 2 pcs M25 2 pcs Factory installati...

Страница 7: ...Medium Intensity 2000cd compact series manual Page 7 of 21 Obelux Oy 2020 Technical information in this document is subject to change without notice Figure 2 Main PCB of a light head AC version...

Страница 8: ...Medium Intensity 2000cd compact series manual Page 8 of 21 Obelux Oy 2020 Technical information in this document is subject to change without notice Figure 3 Main PCB with E EF and IO add on cards...

Страница 9: ...n issued directive 2012 19 EU to contribute to sustainable production and consumption by as a first priority the prevention of WEEE and in addition by the re use recycling and other forms of recovery...

Страница 10: ...size cable glands used on the device M25 cable glands for 6 17 mm cable diameter and M20 cable glands for 6 12 mm cable diameter Make sure that all unused glands or gland holes are sealed Figure 4 Dim...

Страница 11: ...into this pole GND Ground Connect the power supply ground wire into this pole The connectors are Wago Push in CAGE CLAMP type Conductor cross section 0 2mm 4mm 24 12 AWG Recommended conductor size 2 5...

Страница 12: ...s Figure 6 Chaining light heads Figure 7 Distributing power and data to next light head of the network AC version Figure 8 Distributing power and data to next light head of the network DC version When...

Страница 13: ...changing between the modes Stand alone mode In this mode the light operation is configured with its DIP switches No additional controllers are needed Light head will use its internal photocell to det...

Страница 14: ...ing mode based on ambient luminosity DIP switch Photocell mode 6 off Photocell is disabled on Photocell controls the light Turn DIP7 on for correct operation DIP switch Master Slave mode 7 off This de...

Страница 15: ...cell mode 6 off Photocell is disabled on Photocell controls the light DIP switch Master Slave mode 7 off This device is slave on This device is master DIP switch Operating mode 8 off Stand alone on Mo...

Страница 16: ...s disabled on Photocell controls the light Turn DIP7 on for correct operation DIP switch Master Slave mode 7 off This device is slave on This device is master must be on Turn DIP8 off for correct oper...

Страница 17: ...d alone on Modbus Factory default 4 3 Modbus mode The light is in Modbus mode when DIP8 is on Light is being controlled with an Obelux controller DIP switch Operating mode 8 off Stand alone on Modbus...

Страница 18: ...rning on the termination DIP switch on both ends of the communications bus 4 4 Test mode To enter test mode set DIP7 and DIP8 on and all other DIPs off The light will enter test mode when power is tur...

Страница 19: ...Set a lamp to master mode by switching its DIP7 on Set DIP7 off in the slave lamps to put them to slave mode DIP switch Master Slave mode 7 off This device is slave slaves on This device is master mas...

Страница 20: ...OWER Internal operating voltage GREEN LED OFF Unit has power off LED ON Unit has power on COM Communication GREEN LED OFF Waiting for external signals LED FLASHING Master slave communications occurrin...

Страница 21: ...re averaged to avoid sudden state changes Unless test mode is enabled it takes approx three 3 minutes to change system state between day twilight and night Light does not flash in sync GPS antenna is...

Отзывы: