DIP switch
Modbus Address
1
2
3
4
on
off
off
off
Address 01
off
on
off
off
Address 02
on
on
off
off
Address 03
off
off
on
off
Address 04
on
off
on
off
Address 05
off
on
on
off
Address 06
on
on
on
off
Address 07
off
off
off
on
Address 08
on
off
off
on
Address 09
off
on
off
on
Address 10
on
on
off
on
Address 11
off
off
on
on
Address 12
on
off
on
on
Address 13
off
on
on
on
Address 14
on
on
on
on
Address 15
RS-485 bus should be terminated with on-board 120 ohm resistors by turning on the termination DIP switch
on both ends of the communications bus.
4.4 Test mode
To enter test mode, set DIP7 and DIP8 on and all other DIPs off. The light will enter test mode when power
is turned on. To leave the test mode, turn off DIP7 and DIP8 and turn off the power.
DIP switch
Test mode
7
8
on
on
Test mode enabled. All other DIPs off.
off
off
Test mode disabled.
Light mode is selected with DIPs 1-2. There is normally a delay when changing time-of-day modes (day,
twilight and night) based on photocell data. Using accelerated photocell mode will decrease the delay to a
minimum.
DIP switch
Light mode
1
2
off
off
Accelerated photocell light behavior
on
off
RED light only
off
on
IR light only
on
on
Reserved
Flashing rate is selected with DIPs 4-5.
DIP switch
Flash rate (FPM)
4
5
off
off
Steady
on
off
20
off
on
40
on
on
60