Medium-Intensity 2000cd compact series manual
Page
14
of
21
© Obelux Oy 2020 Technical information in this document is subject to change without notice.
4.1 ICAO models
4.1.1 ICAO Stand-alone mode (basic model)
Flashing mode is selected with DIPs 1-3.
Flashing rate is selected with DIPs 4-5. Steady mode
s don’t flash. A steady mode can be selected with DIPs
1-3.
DIP switch
Flash rate (FPM)
4
5
off
off
20
on
off
30
off
on
40
*
on
on
60
Photocell operation is configured with DIP6. When photocell controls the light, the light will change its
flashing mode based on ambient luminosity.
DIP switch
Photocell mode
6
off
Photocell is disabled
*
on
Photocell controls the light
Turn DIP7 on for correct operation.
DIP switch
Master/Slave mode
7
off
This device is slave *
on
This device is master (must be on)
Turn DIP8 off for correct operation.
DIP switch
Operating mode
8
off
Stand-alone (must be off) *
on
Modbus
* Factory default
DIP switch
Flashing mode
1
2
3
Night
off
off
off
2,000cd red, ICAO (flashing, check DIPs 4-5)
on
off
off
2,000cd red and infrared, ICAO (flashing, check DIPs 4-5)
*
off
on
off
2,000cd red (steady)
on
on
off
2,000cd red and infrared (steady)
off
off
on
200cd red and infrared, ICAO (flashing, check DIPs 4-5)
on
off
on
200cd red and infrared (steady)
off
on
on
Reserved
on
on
on
Reserved