background image

sensor is installed, and the receiver receives the sensor The signal sent, the No. 7 wheel is 
successfully matched, "BI-BI" 2 beeps enter the No. 8 wheel matching, the corresponding wheel 
icon flashes; within 2 minutes, the external sensor is installed, and the receiver receives the 
signal from the sensor, No. 8 If the round matching is successful, ID code learning will be 
automatically exited; 
Specify a wheel ID matching can be entered by short pressing the right selection key. 

 

 

 

 

 
 
 

Specifications Dash Unit : 

            Working voltage: 3.7-5V   Display mode: LCD color screen 

 Working current: <13mA    Shutdown current: <0.7mA 
Working temperature: -20 

 ~ 80 

  Storage temperature: -20 

 ~ 85 

 

Transmitting frequency: 433.92MHz ± 20.00MHZ  
Signal receiving sensitivity: -90dbm 
8,Sensor installation diagram: 

 

 

Specifications of Sensors: 

           Battery life: 24 months   Storage temperature: -20 

 ~ 85 

 

           Working voltage: 2.1V-3.3V  Working temperature: -20 

 ~ 85 

 

           Pressure range: 0 

 114/185psi  Pressure accuracy: ± 1.3psi 

           Temperature accuracy: +/- 3 

  Transmitting power: <13dBm 

           Frequency: 433.92MHz ± 20.00MHZ 

Содержание Tyre Watcher X

Страница 1: ...ew Tyre Pressure Monitoring System TPMS design for caravans and the tow car This system is wireless as the dash unit is powered by solar and the wheel sensors send radio signals This system is designed to provide you with an extra safety and improved economy for both fuel and tyre wear ...

Страница 2: ...s order Display Unit setting Pressure PSI or BAR Display Unit Setting Temperature C or F Low Pressure Alarm Vehicle Tyres High Pressure Alarm Vehicle Tyres Low Pressure Alarm Van Tyres High Pressure Alarm Van Tyres Press and hold the middle button for 3 seconds to exit this screen and back to the main screen Stick the unit on your dash where you can see it You should be all set up Quick Disconnect...

Страница 3: ...high pressure value and the unit will exit alarm mode 3 2 After entering the low pressure alarm the pressure needs to rise 1 5psi above the low pressure alarm valve and the unit will exit alarm mode 3 3 After entering the high temperature alarm the temperature drops 2 degrees above the high temperature alarm value to exit the alarm state 3 4 When the receiver receives the fast leakage mark this is...

Страница 4: ...ress the right selection key to enter the ID matching pair 8 flashes then press the left key to start pairing the 1st wheel icon flashes and within 2 minutes install an external sensor the receiver receives the signal from the sensor the 1st wheel When the matching is successful the 2 beeps of BI BI will enter the 2nd wheel matching and the corresponding wheel icon flashes within 2 minutes the ext...

Страница 5: ...matching can be entered by short pressing the right selection key Specifications Dash Unit Working voltage 3 7 5V Display mode LCD color screen Working current 13mA Shutdown current 0 7mA Working temperature 20 80 Storage temperature 20 85 Transmitting frequency 433 92MHz 20 00MHZ Signal receiving sensitivity 90dbm 8 Sensor installation diagram Specifications of Sensors Battery life 24 months Stor...

Отзывы: