background image

1

Arm Digital Blood Pressure Monitor

with Voice Function, Backlight, 

and Touch Screen

Model No.: MM-4750

Please carefully read through this manual before first use, and store it in safe place. 
If you pass the product to another person, hand over this manual along with it!

Your healthy living center

www.obbomed.com

EXPLANATION SYMBOLS

DANGER:  Warning of risk of serious injury or health hazards

WARNING: Warning of risk of injury or health hazards

CAUTION: Safety information about possible damage to appliance/ accessories

NOTE: Important information

INTENDED USE OF PRODUCT

- It is intended to measure the blood pressure and pulse rate of people within the range of the designated arm 
  cuff, follow the instructions in this user's manual.
- It is mainly designed for general household use.
- The device is not suitable for measuring the blood pressure of children. Consult your doctor before using it 
  on older children. 
- The device is not suitable for people with severe arrhythmia. Consult your doctor before use. 
- The device is recommended to be used indoor, in private spaces or at home.

SAFETY & INSTALLATION INSTRUCTION

All below information is to protect the health of users and the product from damage.

Consult your doctor prior to using in pregnancy or if diagnosed with severe arrhythmia or arteriosclerosis. Please read 

this section carefully before using the unit.

- Do not use the unit for any purpose other than measuring blood pressure.
- Always consult your doctor. Self-diagnosis of measurement results and self-treatment are dangerous. 

PRODUCT FEATURES

SCOPE OF DELIVERY (ACCESSORIES)

- Touch Screen Display with Backlight
- Voice Setting: English / German / Spanish
- Memory Storage
- WHO Classification Indicator

- Irregular Pulse Detection
- Body Movement Detection
- Date and Time Stamp
- AC adapter (optional)

- Blood Pressure Monitor Main Unit
- Arm Cuff
- Storage Bag
- User’s manual 
- Battery: four AA batteries included

AC adapter is not included.

0197

Содержание MM-4750

Страница 1: ...t your doctor before using it on older children The device is not suitable for people with severe arrhythmia Consult your doctor before use The device is recommended to be used indoor in private spaces or at home SAFETY INSTALLATION INSTRUCTION All below information is to protect the health of users and the product from damage Consult your doctor prior to using in pregnancy or if diagnosed with se...

Страница 2: ... unit if not used for long time Consult doctor or physician before using this product if you are have Recovering from surgery Tumors acute illnesses or aches Osteoporosis dysesthesia or anemia Diabetes phlebitis thrombosis Heart and vascular diseases Individuals with pacemakers or other implanted electronic devices Under the effects of alcohol sleeping pills or sedatives Arrhythmia or arteriosclero...

Страница 3: ...y press the MEM button and START button for 3 seconds The entry to the month flashes Press the MEM button repeatedly until the desired number for the month appears Press the START button to accept the setting Now the entry to the day flashes Proceed in exactly the same manner when entering the day hour and minute In each case press the MEM button to select and the START button to accept the entry PR...

Страница 4: ... 8 i n c h e s How To Sit Correctly 1 Carry out the measurement whilst comfortably seated 2 The cuff should be at the same level as your heart Fig 2 3 Keep still during the measurement do not move and do not talk as this may alter the measurements USING THE UNIT Fig 1 Fig 2 Fig 3 Fig 5 Fig 4 Fig 6 Take A Reading 1 Ensure the touch screen switch in ON position 2 Press the START button to turn the un...

Страница 5: ...ed the Systolic Blood Pressure the lowest is the Diastolic Blood Pressure Both pressure readings the Systolic and Diastolic are necessary to enable a doctor to evaluate the status of a patient s blood pressure We recommend contacting your physician if you see this indicator frequently Why Measuring Blood Pressure at Home Many factors such as physical activity anxiety or the time of day can influenc...

Страница 6: ...ss the buttons The batteries are empty Replace all batteries with new ones The batteries have been inserted incorrectly Insert the batteries with the correct polarity Lit The batteries are exhausted You should replace them with new ones at once The touch screen switch is in the OFF position Keep the touch screen switch in ON position and try again Display Cuff fails to inflate properly Make sure hos...

Страница 7: ...Blood Pressure Monitor with Voice Function Backlight and Touch Screen Model MM 4750 Display LCD digital display Measurement Method Oscillometric method Cuff Inflation Automatic inflation Memory slots 60 readings Power source DC 6V 600mA 4 x 1 5V Size AA Batteries or AC DC Adapter Optional Battery Life Capacity of new alkaline batteries is approx 180 measurements Applied Part Type BF the cuff is type B...

Страница 8: ...see service e mail at the end of this manual or your retailer For repair and warranty processing please include the following documents when you send in the product A copy of the receipt with purchasing date A reason for the claim or description of the fault No guarantee is provided when the product is not installed operated according to this manual used for other purposes or careless use of the p...