- Do not leave the unit unattended with infants or persons who cannot express their consent.
- Do not disassemble or attempt to repair.
- Protect the unit against moisture. If liquid does manage to penetrate into the unit, remove the batteries 
  immediately and do not continue to use this unit. 
- If battery fluid gets in your eyes, immediately rinse with plenty of clean water. Consult a doctor immediately.

- Use only the approved arm cuff for this unit. Use of other arm cuffs may result incorrect measurement results.
- Do not use a mobile phone or other devices that emit electromagnetic fields, near the unit.  This may result 
  incorrect operation of the unit.
- Do not operate the unit in a moving vehicle (car, airplane).
- Do not take measurement after bathing, drinking alcohol, smoking, exercising or eating.
- Do not inflate the arm cuff when it is not wrapped around your arm.
- Do not leave the cuff wrapped on the arm if taking measurements during the night. This could result in injury.
- Do not apply strong shocks and vibrations to or drop the unit and arm cuff.
- Remove the batteries from the unit if not used for long time.

- Consult doctor or physician before using this product if you are/ have:

• Recovering from surgery 
• Tumors, acute illnesses or aches
• Osteoporosis, dysesthesia, or anemia
• Diabetes, phlebitis, thrombosis 
• Heart and vascular diseases
• Individuals with pacemakers or other implanted electronic devices
• Under the effects of alcohol, sleeping pills or sedatives
• Arrhythmia or arteriosclerosis
• Pregnancy
• Older children
• Under the effects of alcohol, sleeping pills or sedatives.

- If you have any concerns regarding to your health, consult your doctor before using this product.
- Please stop using it immediately if you experience any pain or discomfort while using this product.

HEALTH PRECAUTIONS

OVERVIEW

Irregular heartbeat symbol

Low battery

The presure in cuff is instable, or much remnant air in cuff

Find an error, please re-inflate

2-3 cm

(0.8”-1.2”)

LEFT ARM

Cuff Tube Plug

Rubber Tube

Memory Button

Touch Sceen 
On/Off Button

Start Button

LCD

WHO Classification Indicator

Cuff

 
- People with severe blood flow problems, or blood disorders, should consult a doctor before using the unit, 
  as cuff inflation can cause internal bleeding.
- Do not take any therapeutic measures on the basis of a self measurement. Never alter the dose of a medicine 
  prescribed by a doctor.

Содержание MM-4750

Страница 1: ...t your doctor before using it on older children The device is not suitable for people with severe arrhythmia Consult your doctor before use The device is recommended to be used indoor in private spaces or at home SAFETY INSTALLATION INSTRUCTION All below information is to protect the health of users and the product from damage Consult your doctor prior to using in pregnancy or if diagnosed with se...

Страница 2: ... unit if not used for long time Consult doctor or physician before using this product if you are have Recovering from surgery Tumors acute illnesses or aches Osteoporosis dysesthesia or anemia Diabetes phlebitis thrombosis Heart and vascular diseases Individuals with pacemakers or other implanted electronic devices Under the effects of alcohol sleeping pills or sedatives Arrhythmia or arteriosclero...

Страница 3: ...y press the MEM button and START button for 3 seconds The entry to the month flashes Press the MEM button repeatedly until the desired number for the month appears Press the START button to accept the setting Now the entry to the day flashes Proceed in exactly the same manner when entering the day hour and minute In each case press the MEM button to select and the START button to accept the entry PR...

Страница 4: ... 8 i n c h e s How To Sit Correctly 1 Carry out the measurement whilst comfortably seated 2 The cuff should be at the same level as your heart Fig 2 3 Keep still during the measurement do not move and do not talk as this may alter the measurements USING THE UNIT Fig 1 Fig 2 Fig 3 Fig 5 Fig 4 Fig 6 Take A Reading 1 Ensure the touch screen switch in ON position 2 Press the START button to turn the un...

Страница 5: ...ed the Systolic Blood Pressure the lowest is the Diastolic Blood Pressure Both pressure readings the Systolic and Diastolic are necessary to enable a doctor to evaluate the status of a patient s blood pressure We recommend contacting your physician if you see this indicator frequently Why Measuring Blood Pressure at Home Many factors such as physical activity anxiety or the time of day can influenc...

Страница 6: ...ss the buttons The batteries are empty Replace all batteries with new ones The batteries have been inserted incorrectly Insert the batteries with the correct polarity Lit The batteries are exhausted You should replace them with new ones at once The touch screen switch is in the OFF position Keep the touch screen switch in ON position and try again Display Cuff fails to inflate properly Make sure hos...

Страница 7: ...Blood Pressure Monitor with Voice Function Backlight and Touch Screen Model MM 4750 Display LCD digital display Measurement Method Oscillometric method Cuff Inflation Automatic inflation Memory slots 60 readings Power source DC 6V 600mA 4 x 1 5V Size AA Batteries or AC DC Adapter Optional Battery Life Capacity of new alkaline batteries is approx 180 measurements Applied Part Type BF the cuff is type B...

Страница 8: ...see service e mail at the end of this manual or your retailer For repair and warranty processing please include the following documents when you send in the product A copy of the receipt with purchasing date A reason for the claim or description of the fault No guarantee is provided when the product is not installed operated according to this manual used for other purposes or careless use of the p...