background image

OPERATING INSTRUCTIONS

Please follow any additional  

or deviating operating  

instructions displayed  

at the dispenser. 

 

Ensure that all coupling parts, 

seals and sealing surfaces of 

nozzle and vehicle filling point 

are clean and undamaged. 

Turn off vehicle engine.

Take nozzle from dispenser. 

Align nozzle with vehicle  

sided fill point as shown.

Remove nozzle and put back in 

dispenser nozzle holder.

Push nozzle firmly onto the vehicle 

filling point. 

OFF

On completion of refuelling, 

squeeze and release lever. 

Latch will automatically release.

Fuelling should start automati-

cally OR has to be activated at 

the dispenser. Please follow 

operating instructions displayed 

at the dispenser. 

Hold the lever pulled and lock 

the hold-open latch as shown 

to open the nozzle valve. 
Release the lever and it will stay 

in the open position.

Do not lean on / tilt the nozzle.

In that position, pull the lever.
If the nozzle is correctly coupled, 

a green indicator ring appears 

on the coupling part.

  

 

 

 

Do not drop.

 

 Do not leave on  

 

 the  floor.

 

Always put back  

 

in nozzle holder.

6

DRAFT

Содержание N-CNG P30

Страница 1: ...ENGINEERING LIMITED 129 Birch Avenue Tauranga New Zealand Tel 64 07 928 38 08 Email info oasisngv com N CNG P30 P36 CSA ANSI NGV 1 2017 ISO 14469 2017 CNG NOZZLE INSTALLATION AND OPERATING MANUAL 22...

Страница 2: ...for public and private CNG refuelling stations The nozzle is designed to only allow gas to flow when it is correctly coupled and to not allow uncoupling from the vehicle refuelling receptacle when the...

Страница 3: ...f you suspect a leakage stop refuelling immediately use the emergency button to shut off the dispenser immediately evacuate the area and inform station personnel CNG Natural Gas is extremely flammable...

Страница 4: ...alve or damage vehicle motor parts This device complies with CSA ANSI NGV 1 2017 and ISO 14469 2017 The installation of this device shall conform to the requirements of the authorities having jurisdic...

Страница 5: ...escaping gas A small gas release upon uncoupling is normal If uncontrolled and or permanent gas release to the atmosphere occurs immediately stop fuelling If the leakage continues push emergency butto...

Страница 6: ...vehicle filling point OFF On completion of refuelling squeeze and release lever Latch will automatically release Fuelling should start automati cally OR has to be activated at the dispenser Please fol...

Страница 7: ...ny other common sense procedures generally applicable to equipment of this type The foregoing limitation extends to damages to person or property caused by the unit or damages resulting from the inabi...

Страница 8: ...serial number on the CNG nozzle bodies Excluded are nozzles and parts subjected to wear and tear and damages caused by improper use for example the use with unsuitable media Furthermore excluded are...

Отзывы: