TROUBLESHOOTING

Process failure 

Process failure from oxygen starvation of the biomass: 

If the biomass is starved of oxygen, the typical odours associated with anaerobic 
bacterial treatment will be noticed. This is caused by insufficient air flow into the 
biological zone. A blockage in the air line or blower is the most probable cause. 
a)    The inlet screens have been located on each end of the blower housing. If one 

screen becomes blocked by debris, the opposite screen should still be sufficient. 
The suggested routine preventative maintenance calls for brushing off the screen 
as needed. The configuration of the inlet screens and the required maintenance 
will protect the unit from oxygen starvation due to insufficient air flow.

b)    The blower is equipped with an inlet air filter. If this filter becomes blocked with 

debris, it could cause oxygen starvation of the biomass. The blower inlet filter 
should be checked every 6 months and replaced as needed.

10

Visual evaluation 

Wastewater backup is characterised by wastewater flowing back into the house or 
slow movement of wastewater in the drains. This may indicate a problem with your 
wastewater treatment system unit. Identify where the backup is occurring within your 
plumbing system. If you cannot locate material blocking the drain contact your service 
provider.

No use for an extended period

The Oasis Series 3000 Wastewater Treatment System will function normally even if 
wastewater does not enter the system for 5 days. 
The power to the system should be left on during short periods when there is no 
wastewater flow to the system. If the system will not be used for several months or 
longer, you should contact your service provider so the system can be checked for 
proper operation and serviced if necessary. A slight odour may be detected for a few 
days while the system returns to normal operation. 

CONT... 

SYSTEM MAINTENANCE  

AND MONITORING

Содержание 3000 Series

Страница 1: ...OWNER S MANUAL OASIS SERIES 3000 WASTEWATER TREATMENT SYSTEM...

Страница 2: ...future reference If you have questions regarding the safety and operation of your Series 3000 Sewerage Treatment System contact your local authorised Service Technician Do not attempt to service compo...

Страница 3: ...ENT SYSTEM 1 CONTENTS An overview 2 How the system works 3 Putting stuff into the system 4 System maintenance and monitoring 8 Troubleshooting 10 Service procedure 14 Instructions for controller 15 Al...

Страница 4: ...w how the Oasis Series 3000 Wastewater Treatment System works Process flow may differ from one location to another 1st Chamber Primary settling Pump Chamber Pumps to irrigation field 5th Chamber Clari...

Страница 5: ...g to a secondary treatment chamber Liquid flows into the aeration chambers where with the use of our exclusive fine air diffuser assemblies thousands of tiny air bubbles provide oxygen for aerobic dig...

Страница 6: ...ances that reduce the efficiency or stop the treatment process can be grouped into two groups prohibited matter and limited use substances While the Wastewater Treatment System will process most domes...

Страница 7: ...ns condoms baby wipes and disposable napkins Toxic substances such as pesticides herbicides strong disinfectants and strong caustic drain cleaners Large amounts of paper products such as paper towels...

Страница 8: ...to the manufacturer s directions don t use these substances very often and do not introduce concentrated doses into the system Laundry bleach Detergents with bleach Household cleaners containing sodi...

Страница 9: ...e treated by the system but will remain in solid form and fall to the bottom of the septic tank Therefore you should consider not using a waste grinder system Do not dispose of these food items throug...

Страница 10: ...ice policy which includes two inspection service calls per annum to ensure proper operation of the system During these service calls the authorised service person will check the blower for proper oper...

Страница 11: ...lower is not operating follow the procedures given under alarm wiring Flooding Flood water may cover the septic unit the blower housing or both affecting the electrics if the system is installed in a...

Страница 12: ...tarvation of the biomass The blower inlet filter should be checked every 6 months and replaced as needed 10 Visual evaluation Wastewater backup is characterised by wastewater flowing back into the hou...

Страница 13: ...lure high flows etc and correct The blower has failed Determine if blower failure was caused by an obstructed intake or discharge line Investigate overheating i e internal thermal overload protection...

Страница 14: ...d lateral field piping visually or with drain cleaning equipment for an obstruction and correct The flow rate to the system is too high Check the maximum flow rate to the system to see that it is with...

Страница 15: ...The blower and air piping are not operating correctly Check the blower vents and air piping for proper operation The system is overloaded Check the maximum flow rate to the unit to see that it is wit...

Страница 16: ...rking 7 Double check the audio visual alarm and make sure the Mute button is in the ON position 8 Irrigation field inspection and dripline line flushing Servicing procedure 1 Ensure correct NAME ADDRE...

Страница 17: ...ion of 24 hours as a reminder that the plant is not operating correctly The visual alarms cannot be turned off until all faults are rectified Introduction The Oasis Clearwater Control Panel has a numb...

Страница 18: ...p of turret and secure hose onto air pipe High Water Fault High Level Fault Call 0800 484 849 The fluid level in the irrigation tank is high Check irrigation filter is clean Check that the pump is run...

Страница 19: ...ALARM LED TANK ALARM TEXT REMOTE PANEL CAUSE SOLUTION N A Oasis Clearwater System OK Oasis Clearwater Holiday Mode alternates The irrigation pump has not run in 48 hours This is not a fault condition...

Страница 20: ...try to reset the system with the following sequence a Turn the system OFF using the control panel ON OFF switch on the side of the panel This will reset the programme b Turn the system ON using the ON...

Страница 21: ...ed industry information Such recommendations do not constitute a warranty of satisfactory performance This LIMITED WARRANTY extends to the ultimate consumer of the product As herein ultimate consumer...

Страница 22: ...Head Office A PO Box 16276 Hornby Christchurch 8441 P 0800 48 48 49 F 03 344 0267 E office oasisclearwater co nz W oasisclearwater co nz oasisclearwater co nz...

Отзывы: