SE SERIES SINGLE-ELEMENT CARTRIDGE FILTER INSTALLATION AND OPERATION MANUAL
Page
8
of
19
STARTING PUMP
Stand clear of pump during start-up
Pool and spa circulation systems operate under high
pressure. When any part of the pool filtration system is
serviced, air can enter the system and become pressurised.
Pressurised air can cause the cartridge filter top assembly to
separate, resulting in severe injury, death, or property
damage.
Upper body and lock ring must be secured to prevent violent separation.
1. Switch on filter pump. When pump starts, do not stand over or near filter.
NOTE: If water leakage appears at the main lock ring, immediately turn off all pumps,
electrical equipment and stand away from the filter until the water leak has stopped, before
inspecting further.
2. If closed, loosen air relief valve approximately one and a half turns and wait for a constant stream
of water to exit. Gently close valve only enough to seat the seal
(do not overtighten)
.
OPERATION
Filtration starts as soon as the flow is steady through the filter. As the filter removes particles from the
pool water, this accumulates in the filter element. The pressure inside the filter will gradually rise over
time, resulting in reduced water flow.
1. Record the initial starting pressure which is the initial pressure reading when a new filter element
is working under filtration conditions. This measurement
should be taken once all air is bled from the filtration system.
2. Each time the filter element is cleaned or replaced, the gauge
ring should be adjusted to align the needle with the “Start”
marking, once all air is bled from the system
3. Monitor the pressure over time and when the needle reaches
the “Clean Filter” mark, clean or replace the filter element as
per the instructions.
Installing a new filter element.
You should replace the filter cartridge element:
1. If after cleaning and installing the filter element, if the pressure is:
a. Reading 10 psi higher than the initial
‘start’ reading when the element was new, or
b. Is reading over 30 psi.
2. When the filter element is broken, or the layers are peeling.
3. When the pressure or flow rate is below the desired rate of the system.
Содержание Oasis SE Series
Страница 1: ......
Страница 17: ...SE SERIES SINGLE ELEMENT CARTRIDGE FILTER INSTALLATION AND OPERATION MANUAL Page 16 of 19 15 NOTES...
Страница 18: ...SE SERIES SINGLE ELEMENT CARTRIDGE FILTER INSTALLATION AND OPERATION MANUAL Page 17 of 19...
Страница 19: ...SE SERIES SINGLE ELEMENT CARTRIDGE FILTER INSTALLATION AND OPERATION MANUAL Page 18 of 19...