3. 

HOW IT WORKS 

Oasis Aquatics SE Series Filters

 utilise multiple reusable, reinforced polyester filter cartridge elements 

to provide a high degree of water clarity and long filter cycles with minimum care. 

With maximum flow ratings between 380 and 455 litres per minute (LPM), they are designed for continuous 
or intermittent operation, when installed both above or below the pool waterline.  

Oasis Aquatics SE Series Filters

 are compatible with freshwater, saltwater and mineral pools and spas. 

 

4. 

INSTALLATION 

The filter should be installed as close to the pool as possible while keeping a minimum distance of 1.5m 
away from the waters edge. Locate the filter on clean, rigid and level surface, preferably in a dry, shaded, 
and well-ventilated area.  

Prior to installation take into consideration the following conditions: 

  Position of suction and return PVC connections 

  Access for cleaning operation and servicing, particularly important if installing under a deck or roof 

structure that enough space is provided to remove the element for cleaning 

  The operation of the air relief which discharges water from the filter, you must position the filter in 

a way which witch prevents this water from reaching any electrical equipment which would present 
a risk of electric shock or electrocution. 

  Protection from sun, rain, splashing etc 

  Drainage  of  mounting  area,  ensuring  that  it  does  not  flood  when  it  rains,  or  when  the  filter  is 

serviced. 

  Ventilation and protection of the full filtration system from any chemical fumes or spills.  

1.  Place the complete filter assembly in position. 

a.  Position filter body such that all operation and safety labels are visible. 

b.  Ensure that the mounting position is level and stable. 

2.  Do not locate electrical equipment over or near filter. 

3.  Ensure that water discharge from the air relief valve will not reach any electrical equipment when 

the filter is bled. 

4.  Make sure that there is ample room above and around the filter to allow clear access for regular 

maintenance activities. 

5.  Connect the pool suction PVC pipe plumbing between the skimmer, the pool outlet (from the pool), 

and the pump. 

6.  Install the plumbing from the filter to the pool (return to the pool) 

 

 

 

REQUIRED CLEARANCE 

Model 

 

cm

 

cm

 

cm 

 

SE100 

82.7 

47 

30 

SE150 

91.2 

47 

30 

SE200 

103.4 

47 

30 

Содержание Oasis SE Series

Страница 1: ......

Страница 2: ...hase Date Installer Warranty Registered Online Yes No See page 15 for details PRESSURE GAUGE READING RECORD Initial Reading Date PSI kPa Date PSI kPa Date PSI kPa Date PSI kPa Date PSI kPa Date PSI kP...

Страница 3: ...YSTEM 7 BEFORE STARTING THE PUMP 7 STARTING PUMP 8 OPERATION 8 6 MAINTAINING YOUR FILTER 9 FILTER DISASSEMBLY INSTRUCTIONS 9 REMOVING CARTRIDGE 9 CLEANING CARTRIDGE 9 FILTER REASSEMBLY INSTRUCTIONS 9...

Страница 4: ...ulting your dealer or a qualified pool technician b Read the entire Installation Operation Manual before attempting to use service or adjust the pool filtration system 2 Before repositioning valve s a...

Страница 5: ...r or near filter Due to the potential risk that can be involved it is recommended that any pressure tests are kept to the minimum time required by the relevant local codes Do not allow people to work...

Страница 6: ...owing Health and Safety Concerns Installation requirements How to operate the major features of the unit The importance of maintenance If you have a problem what you can do to trouble shoot before you...

Страница 7: ...is provided to remove the element for cleaning The operation of the air relief which discharges water from the filter you must position the filter in a way which witch prevents this water from reachin...

Страница 8: ...sure that the pressure gauge air relief valve and drain plug are installed Note that each of these contains a sealing o ring 3 Loosen and retighten the filter lock ring ensuring that the latch clicks...

Страница 9: ...n starts as soon as the flow is steady through the filter As the filter removes particles from the pool water this accumulates in the filter element The pressure inside the filter will gradually rise...

Страница 10: ...best results carefully brush the pleated surface to remove fine particles Do not use high pressure water to wash as it can damage the filter element You may find some debris on the cartridge pleats wh...

Страница 11: ...als of the Cartridge Filter to break under the intense pressure of expanding water It is your responsibility to monitor temperatures and take the following actions In mild climate areas when temporary...

Страница 12: ...ution available from most pool shops Water Is Not Clear Check chlorine pH and total alkalinity levels and adjust as required Filter could be dirty clean the elements as per instructions and restart Be...

Страница 13: ...inators or Heaters are well vented to protect against extremes of temperature however this creates a popular environment for ants and other insects who are attracted to the warmer dry environments ins...

Страница 14: ...D306Xd7 5 1 7 430178159 Union nut 2 2 8 430308158 Union 2inch 2 5inch ANSI 2 8 430309780 Union 1 5inch 2inch 2 8 430309779 Union GB50 2 8 430309059 Union GB63 2 9 111040071 O ring D77Xd62X8 2 10 E1404...

Страница 15: ...liable for damage caused by but not limited to corrosion scaling or stress This warranty does not apply if failure is due to any abuse misuse improper installation or accident or to any of the follow...

Страница 16: ...s that should only be performed by or under the direction and advice of your local Professional and under no circumstances should the guide be used as a substitute for such professionals No represent...

Страница 17: ...SE SERIES SINGLE ELEMENT CARTRIDGE FILTER INSTALLATION AND OPERATION MANUAL Page 16 of 19 15 NOTES...

Страница 18: ...SE SERIES SINGLE ELEMENT CARTRIDGE FILTER INSTALLATION AND OPERATION MANUAL Page 17 of 19...

Страница 19: ...SE SERIES SINGLE ELEMENT CARTRIDGE FILTER INSTALLATION AND OPERATION MANUAL Page 18 of 19...

Страница 20: ...A part of the Victoria 6 8 Austral Place Hallam VIC 3803 Australia T 03 9887 2131 New South Wales Unit 2 10 Boden Road Seven Hills NSW 2147 Australia T 02 9838 0000 Queensland 11 Andys Court Upper Co...

Отзывы: