background image

 

M SERIES M150 | M175 | M250 POOL & SPA PUMP INSTALLATION AND OPERATION MANUAL

 

 

[email protected] 
oasisaquatics.com.au 

3

 

 

DANGER - HAZARDOUS SUCTION! 

 

Do not block water entry into filtration system with any part of your body as the suction can trap hair 
or  body  parts,  causing  severe  injury  or  death.  Do  not  block  suction.  Turn  off  pump  immediately  if 
someone becomes trapped. 

CAREFUL REMINDER 

 

This  appliance  is  not  intended  for  use  by  persons  (including  children)  or  person/s  with  reduced 
physical,  sensory  or  mental  in

capability’s

,  or  lack  of  experience  and  knowledge,  unless  they  have 

supervision or instruction concerning use of the appliance by a person responsible for their safety. 

 

Please check your pump basket, skimmer and entire pool system regularly to maximize the life of 
your pool equipment & personal safety. Turn pump off first before checking baskets. 

 

Make sure that all pressure gauges installed are in working condition and the operating pressure is 
within limits as specified on the product. 

 

Make sure that each suction inlet, and main drain has a cover that is securely attached and in safe 
working condition to meet with all current legislation. 

 

Make sure that all skimmer covers (deck lids) are securely attached and in safe working condition. 
These should be replaced every 3 to 4 years. 

 

Remove any obstructions or debris from the main drain cover. 

 

Ensure  the  skimmer  baskets  and  the  pump  hair  and  lint  pots  are  free  of  leaves  and  debris  at 
regularly. 

 

Remove obstructions and combustibles from around the pump motor. 

 

Make sure all wiring connections are clean and that all wiring and electrical equipment is in good 
condition.  Damaged  wiring  must  be  repaired  or  replaced  by  a  qualified  electrician  as  soon  as 
damage is discovered. 

 

Do not add chemicals directly to the pool skimmer. Adding undiluted chemicals may damage pump, 
heater, etc and void warranty. 

 

Check water balance and sanitizer levels at your local pool shop. 

WARNING!  

CHILDREN SHOULD BE SUPERVISED AT ALL TIMES TO ENSURE THAT DO NOT PLAY WITH 

THE PUMP OR ANY POOL ASSOCIATED ELECTRICAL DEVICE

 

 

Pump suction is hazardous and can cause entrapment, drowning or disembowel bathers. 

 

Do not block or cover any pool/spa suction. 

 

Do not use or operate swimming pools, spas or spa baths if a suction cover is broken, missing or 
loose.  

 

Suction covers and inlets must be installed as per Australian Standards guideline and provided for 
every pump to avoid suction entrapment. 

 

Two suction covers (500mm apart) and inlets  must be provided into every pump to avoid suction 
entrapment. 

CAUTION! 

 

In the interest of safety, we advise that all brands and types of pool pumps must be installed in 
accordance with AS3000 wiring rules or equivalent 

 

If the pump and filter are located below pool water level, it is necessary to fit isolating valves in the 
pipe between the pump and the skimmer box and in the return pipe from the filter to the pool. 

 

The fittings on this product are constructed of ABS. Some PVC jointing compounds are incompatible 
with ABS. Check compound suitability before use. 

 

OASIS recommends that all installations are fitted with earth leakage or residual current protection 
devices. 

 

Ensure  that  an  electrical  isolation  switch  is  located  with  easy  access  so  that  the  pump  can  be 
switched off in an emergency. 

Содержание M Series

Страница 1: ...OPERATION MANUAL M SERIES Pool Spa Pump M SERIES Pool Spa Pump M150 M175 M250 Head Office 62 Parkhurst Drive Knoxfield VIC 3180 T 03 9887 2131 New South Wales Unit 1 20 22 Foundry Road Seven Hills NSW...

Страница 2: ...INSTALLATION AND OPERATION MANUAL info oasisaquatics com au oasisaquatics com au 2 PLEASE READ THESE INSTRUCTIONS BEFORE OPERATING Please pass these instructions on to the owner of this equipment MOD...

Страница 3: ...e all wiring connections are clean and that all wiring and electrical equipment is in good condition Damaged wiring must be repaired or replaced by a qualified electrician as soon as damage is discove...

Страница 4: ...ve equipment OASIS pool and spa pumps are designed to operate with most chlorinators heaters and other pool equipment producing correct water flow and energy efficiency FEATURES BENEFITS Powerful high...

Страница 5: ...ON It is recommended that the pump be protected from the weather Enclosures should be ventilated to allow a free flow of air for the fan cooled motor POWER CONNECTION OASIS pool and spa pumps are suit...

Страница 6: ...and may cause damage to the pump voiding warranty A straight length of pipe measuring no less than 300mm should be installed in front of the inlet of the pump allowing quieter and smoother operation...

Страница 7: ...d indicates an air leak in the suction piping work which should be rectified to avoid pump damage 5 If water flow through the pump is continuously tedious to obtain at start up after cleaning the lint...

Страница 8: ...w 1 Switch off pump 2 Unscrew the hair and lint pot strainer basket lid anti clockwise and remove 3 Remove the hair and lint pot strainer basket by lifting upwards from its housing 4 Empty the trapped...

Страница 9: ...Customer Service Centre at the address indicated in this manual If the pump runs but there is no water flow or water flow is reduced the following condition may apply 1 The filter requires backwashing...

Страница 10: ...pump is not intended for use by young children or infirm persons without supervision Ensure that young children are supervised at all times to ensure that they do not play with the pump COMMERCIAL INS...

Страница 11: ...failure is due to any abuse misuse improper installation or accident or to any of the following Improper chemical balance in the water Incorrect power supply and or connection Water damage from extern...

Страница 12: ...UAL info oasisaquatics com au oasisaquatics com au 12 A part of the group Victoria 62 Parkhurst Drive Knoxfield VIC 3180 Australia New South Wales Unit 1 20 22 Foundry Road Seven Hills NSW 2147 Austra...

Отзывы: