manualshive.com logo in svg
background image

 

- GB - 

 

Maintenance and cleaning (D-I) 

 

Attention! Dangerous electrical voltage. 
Possible consequences:

 Death or severe injury. 

Protective measures:

 Disconnect the power plug (C, 6) prior to reaching into the water and commencing 

work. 

Regular cleaning (D, E): Remove the filter basket (6) and the foam filter (7) from the unit, rinse with clean water and 
reinstall. 
Complete cleaning (F-H): Take the unit out of the water. Remove the air distributor (4) located beneath the pump 
chamber (3). Press in the engagement lugs on three sides of the pump chamber (3) and remove the container (2). 
Ensure that the air hose (9) does not slip off the injector (10). Remove the pump (10) and undo the union nut of the 
injector (8). Clean all components using clean water and a brush. 
Cleaning the pump (I): Open the pump cover (11) with the bayonet closure and remove the impeller (12). Clean all 
components using clean water and a brush. 
Reassembly: After cleaning the pump and the unit, reassemble in the reverse order. 
Important: Route connection cable such that it cannot be pinched. Ensure that the air hose (G, 9) is routed without 
kinks. The engagement lugs must audibly click when reassembling the pump chamber (3) and the container (2). Align 
the air distributor (4) as shown in figure B. 

 

Malfunctions 

Malfunction Cause  Remedy 

The unit is not operating 

No mains voltage 

Check mains voltage 

Impeller blocked 

Clean 

Filter basket / foam filter soiled 

Clean 

Insufficient delivery rate 

Injector blocked 

Clean 

No aeration 

The aerating hose between the floating body 
and the injector is kinked or disconnected 

Ensure secure fastening and avoid kinks in the 
aerating hose 

Unit switches off after a short running period 

Water temperature too high 

Note maximum water temperature of + 35°C 

 

 

Storage/Over-wintering 

Remove the unit at temperatures below zero degrees centigrade. Thoroughly clean and check the unit for damage. 

 

 

Store the unit immersed in water or filled with water in a frost-free place. Do not flood the power plug! 

 
 

Wear parts 

Foam filters and impeller vanes are wearing parts; for this reason they are excluded from our warranty. 

 

Disposal 

 

 

Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided. 
Disable the unit beforehand by cutting off the cables. 

Отзывы: