Malfunction
Cause
Remedy
Pump does not start. The pump is switched off.
Switch on the pump.
Power supply interrupted
Check the electrical plug
connections.
The fault current protection de-
vice has tripped.
Switch off the pump and
disconnect the power plug.
Then contact the OASE
Service.
The pump has been out of ser-
vice for a prolonged time (e.g.
during the winter). The impeller is
stuck.
Insert a screwdriver
through the rear service
hole, turn to release the im-
peller.
The pump is not de-
livering, or the deliv-
ered quantity is insuf-
ficient.
The pump is not sufficiently filled
with water.
Fill the pump and ensure
that the water does not flow
out on the pressure side.
Pressure line blocked
•
Open the water with-
drawal point on the
pressure side.
•
Route the pressure hose
without kinks.
Suction line blocked
•
Clean the connection on
the suction side and the
suction line
•
Route the suction hose
without kinks
Leak on the suction side
Eliminate leak on the suc-
tion side
Filter cover seal defective.
Replace the filter cover
seal.
Filter cartridge of the pump
clogged.
Clean or replace the filter
and filter cover.