- EN -
15
1.
Loosen and remove the screws at the side of
the pump lid.
2.
Remove the pump lid.
3.
Remove the impeller unit.
–
If necessary, use a wide-blade screwdriver
to lever the impeller unit out of its posi-
tion in the motor housing. For this, insert
the screwdriver blade into the groove be-
tween the impeller unit and motor hous-
ing, and firmly turn the screwdriver in or-
der to dislodge the impeller from its posi-
tion.
–
Proceed carefully so as not to damage the
motor housing or O ring.
4.
Clean or replace the impeller unit and subse-
quently reassemble the pump in the reverse
order.
–
OptiMax 4000/5000: Firmly push the im-
peller unit into position in the motor
housing.
REMEDY OF FAULTS
Malfunction
Cause
Remedy
The unit does not start up
No mains voltage
Check the mains voltage.
Impeller unit blocked
Clean
Water flow insufficient
Position of the flow regulator
Readjust the flow regulator.
Filter housing or impeller unit
soiled, hose blocked
Clean
Hose defective
Replace
Hose kinked
Route hose in a straight line
Impeller unit worn
Replace impeller unit
Only submersed during installa-
tion
Filter housing clogged
Clean the filter housing.
WEAR PARTS
The following components are wear parts and
are excluded from the warranty:
•
Suction cups, impeller unit
REPAIR
A damaged unit cannot be repaired and must be
put out of operation. Dispose of the unit in ac-
cordance with the regulations.
Содержание OptiMax 2000
Страница 2: ...2 OptiMax 2000 3000 4000 5000 A OIX0008...
Страница 3: ...3 B OIX0010...
Страница 4: ...4 OptiMax 2000 3000 4000 5000 C OIX0013...
Страница 5: ...5 D OIX0009...
Страница 6: ...6 OptiMax 2000 3000 4000 5000 E OIX0012...
Страница 18: ...128 OptiMax 2000 3000 4000 5000 UA 1 RU 1 CN 1...
Страница 19: ...129 OIX0004...
Страница 20: ...43025 01 16...