En
glis
h
7
Operation without water feature
For operation without water feature you can place or hang up the device horizon-
tally. (
•
Tighten screw connections hand-tight.
Filtral UVC 400:
•
Connect the hose of a watercourse/water spout to the side outlet of the branch
valve. The other outlet either remains free or you connect a Venturi nozzle (option-
ally available, 70364) using a reduction element (1 in on ½ in).
Filtral UVC 800, 1600:
•
Connect the Venturi nozzle to the side outlet of the branch valve. At the other out-
let connect the hose of a watercourse/water spout using the stepped hose adapter.
Filtral UVC 400
Filtral UVC 800, 1600
FTL0038
FTL0035
Installation
WARNING
Severe injuries or death due to operation of this unit in a swimming pond. Defective
electrical components will electrify the water with dangerous electrical voltage.
Never operate the unit in a swimming pond.
WARNING
The unit is subject to dangerous voltage and must not be installed directly adjacent
to the water. Otherwise there is a risk of severe injuries or death by electrocution.
Install the unit at a distance of at least 2 m from the water to ensure that it is pro-
tected against flooding.