36
Instruction for use
9. Pull out the flat seal and the protective tube between the lid and
the Filtoclear UVC and clean with water. Check the parts for
damage and replace if necessary. Fit the flat seal under the ring
of the protective tube (see illustration) and insert in lid together.
10.Insert the Filtoclear UVC in the lid of the filter and screw the four
screws on tight by hand (2 Nm).
11.Start the pressure filter up again. (see “Starting up the
pressure filter“).
Storage / winter storage
When frost is expected, you must remove the Filtoclear with
integrated UVC! Clean it thoroughly (see Cleaning and maintenance
of the Filtoclear). Check the Filtoclear with integrated UVC for any
damage. Store the Filtoclear with integrated UVC in a dry and frost-
free place. The place of storage must be inaccessible to children.
Advice on disposal
Please dispose of your Filtoclear with integrated UVC in an
environmentally friendly way. Contact your local refuse department
for advice on disposal.
UVC lamps must not be disposed of with domestic waste! Remove
the UVC lamp from the unit and take it to a collection point, so that
it can be disposed of in an environmentally responsible way.
Repair / cable replacement
For repair / cable replacement please send the defective Filtoclear
with integrated UVC directly to the supplier / manufacturer.
Available spare parts are listed under Product overview.