Cleaning/replacing the impeller unit 

 

Remove the pump cover or pump housing from the motor housing by turning it 
counter-clockwise (bayonet catch). 

 

After removing the impeller unit, clean all parts under running tap water. 

 

Replace a worn or damaged impeller unit. 

 

Assemble in the reverse order. 

 

 

ARS0046 

 
 

Storage/winter protection 

The unit is not frost-proof and has to be removed and put into storage if minus tem-
peratures are expected. 

How to correctly store the unit: 

 

Thoroughly clean the unit, check it for damage and replace any damaged parts. 

 

Store the pump submerged and in a frost-free environment. 

 

Malfunction remedy 

 

Malfunction Possible 

cause 

Remedy 

Pump does not run 

No mains voltage 

Check the mains voltage. 

Impeller unit blocked 

Clean the impeller unit 

Insufficient delivery rate 

Impeller unit running slug-
gishly 

Clean the impeller unit 

Filter housing clogged 

Clean the filter housing. 

Pressure loss in the hose too 
high 

 

Reduce the hose length and 
connecting pieces to a mini-
mum 

 

Route hose in a straight line 

Unit switches off after a short 
running period 

Water temperature too high 

Adhere to the maximum water 
temperature of +77 °F (+35 °C) 

Unit is overloaded 

 

Remove blockage 

 

The unit will switch on 
again automatically as soon 
as it has cooled down. 

Содержание Aquarius Fountain Set Eco 1100

Страница 1: ...English Fran ais Espa ol Aquarius Fountain Set Eco 250 550 825 1100 Operating instructions Notice d emploi Instrucciones de uso...

Страница 2: ...nit Do not carry or pull the unit by its power cable Route lines in such a way that they are protected from damage and do not present a tripping hazard Protect the plug connections from moisture Do no...

Страница 3: ...a malfunction or break down the electric current is discharged through the grounding and the risk of electric shock is reduced Grounding instructions The unit is equipped with a power cord with a gro...

Страница 4: ...INSTRUCTIONS 2 Product Description 5 Intended use 6 Installation and connection 6 Commissioning start up 8 Maintenance and cleaning 8 Storage winter protection 9 Malfunction remedy 9 Technical data 1...

Страница 5: ...pout 5 Union nut for fastening the nozzle pipe on the branch valve 6 Nozzle pipe 7 Nozzle mount 8 Nozzle inserts Vulkan Lava Magma for different water patterns Symbols on the unit The unit is dust tig...

Страница 6: ...tions apply to the unit Do not use in swimming ponds Never use the unit with fluids other than water Never run the unit without water Do not use for commercial or industrial purposes Do not use in con...

Страница 7: ...ctrocution Install the unit at a distance of at least 2 m from the water to ensure that it is pro tected against flooding Ensure that the connection to the power supply is at least 6 6 ft from the pon...

Страница 8: ...immediately Switching off Pull the power plug from the outlet Maintenance and cleaning NOTE Never use chemical cleaning agents These are hazardous to animals plants and the environment Only use clear...

Страница 9: ...any damaged parts Store the pump submerged and in a frost free environment Malfunction remedy Malfunction Possible cause Remedy Pump does not run No mains voltage Check the mains voltage Impeller uni...

Страница 10: ...r column ft 4 2 6 9 8 5 9 8 mwc 1 3 2 1 2 6 3 0 Max pump immersion depth m 2 2 2 2 ft 6 56 6 56 6 56 6 56 Water feature connection in 1 1 1 1 Stepped hose adapter in 1 1 1 1 Dimensions Length in 8 1 8...

Страница 11: ...1 Wear parts Impeller unit Disposal NOTE Do not dispose of this unit with household waste Dispose of the unit by using the return system provided for this purpose Render the unit unusable by cutting t...

Страница 12: ...ARS0047...

Страница 13: ...OASE North America Inc 330 274 8317 www atlantic oase com 77950 08 20...

Отзывы: