- EN -
13
- EN -
Translation of the original Operating Instructions
Information about these operating instructions
Welcome to OASE Living Water. You made a good choice with the purchase of this product
AquaMax Eco Titanium
50000
.
Prior to commissioning the unit, please read the instructions of use carefully and fully familiarise yourself with the unit.
Ensure that all work on and with this unit is only carried out in accordance with these instructions.
Adhere to the safety information for the correct and safe use of the unit.
Keep these instructions in a safe place! Please also hand over the instructions when passing the unit on to a new owner.
Symbols used in these instructions
GB
The symbols used in this operating manual have the following meanings:
Risk of injury to persons due to dangerous electrical voltage
This symbol indicates an imminent danger, which can lead to death or severe injuries if the appropriate
measures are not taken.
Risk of personal injury caused by a general source of danger
This symbol indicates an imminent danger, which can lead to death or severe injuries if the appropriate
measures are not taken.
Important information for trouble-free operation.
A Reference to one or more figures. In this example: Reference to Fig. A.
Reference to another section.
Scope of delivery
A
AquaMax Eco Titanium 50000
1 Pump
2
AquaMax Eco Control
3
Retaining frame for fastening the device to the wall, or for fitting it to the ground stake or holding clip
4 Ground
stake
5
Holding clip for fastening the device to the pump handle
6
Instructions for Use AquaMax Eco Control
7 Protection
cap
Protects against serious injury when the pump is running and there are no pipes connected to the inlet or outlet.
Keep the protection caps in a safe place and always fit them as soon as connected pipes are removed.
Product Description
B
AquaMax Eco Titanium 50000
1 Pump
casing
The position of the outlet can be changed by fitting the pump casing rotated through 90°.
2
DMX line connection
The pump can be (optionally) controlled via DMX/RDM with AquaMax Eco Control or InScenio FM-Master WLAN.
This manual does not contain a description of the connection and operation of DMX/RDM. For information please contact your specia-
list dealer or OASE.
Important
: Moisture at the connections can damage the pump.
Only remove the protection caps for connecting the DMX lines.
Ensure that the rubber seals are clean and fit exactly.
Replace damaged rubber seals.
3 Stand
Ensures secure and stable positioning of the pump.
Can be firmly bolted to the ground.
4 Outlet
(pressure
socket)
75
mm (3")
5 Inlet
(suction
socket)
75
mm (3")
Содержание AquaMax Eco Titanium 50000
Страница 2: ...2 A AMX0045 B AMX0038 C AMX0035...
Страница 3: ...3 D AMX0037 E AMX0042...
Страница 4: ...4 F AMX0040 G AMX0043...
Страница 5: ...5 H AMX0041...
Страница 16: ...163 AMX0044...