Oakworks QuickLock™ Face Rest has virtually unlimited positioning.

1.  Show your client how to get on the chair.

2.  Release the cam locks and knobs on the face rest. (Fig.1)

3.  Ask your client to sit down and hold onto the face rest on the Hook and Loop 

Fastener on the sides of the “U” tube. (Fig.2) 

4.  Tell your client to pull the face rest toward his/her forehead until it rests comfort-

ably on the pad.

5.  Have your client lean forward, letting the chair support his/her weight until in a 

relaxed position.  

6.  Lock the cam locks first and then tighten the knobs. 

• 

Do not over tighten the knobs - too much force may cause stripping. (Fig.3)

• 

The face rest can be moved up and down after loosening the knobs and 
angled after releasing the cam locks.

• 

The face rest platform cam locks are reversible   

Fig. 1

Fig. 2

 Fig. 3

FACE REST ADJUSTMENTS FOR OPTIMAL CLIENT COMFORT

DIRECTIONS FOR USE

• 

Have your client stand on the right side of the chair and grasp the chair frame just above the chest pad for support.

• 

Have the client straddle the seat and place left knee on the left knee pad (farthest away from their body).

• 

Your client can then gradually begin to sit down. Once seated, the client can put right knee on the right knee pad.

• 

You can then make the proper adjustments to the face and arm rests for proper client comfort and positioning.

HELPING YOUR CLIENT ONTO THE CHAIR

• 

Adjust seat height higher for those short clients who are having trouble getting 
comfortably into the face rest. 

• 

Reduce knee flexion by raising the seat and the chair height. Some clients may 
find it more comfortable to put their feet flat on the floor.

• 

Short, heavy or large-breasted clients will be more comfortable with the face rest 
moved toward them, over the chest pad.

• 

The Sternum Pad  (Fig. 4) helps you maximize the effects of treatments.  
Position the sternum pad vertically when doing shoulder work or for large- 
breasted clients. Position the sternum pad horizontally with the ridge just below 
the breasts for pregnant women.  

• 

Use the sternum pad for supporting the cervical region.  Replace the face-rest 
pad with the sternum pad.  Release the cam locks and knobs, and move the ster-
num pad so that the ridge of the sternum pad supports the cervical spine. You may 
have to lower the seat or provide a foot stool for shorter clients.

• 

To seat clients backwards in chair, turn the face pad around so that the curve of 
the “U” supports your client’s neck and lower the seat so that it is parallel to the 
floor.  (Fig. 5)

STERNUM 

PAD

Fig. 5

TIPS FOR PERFECT POSITIONING

4

 Fig. 4

Содержание PORTAL PRO

Страница 1: ...360 Access 350 lb weight rating www oakworksmed com 717 235 6807 made in the USA with US imported parts PORTAL PRO Massage Chair OAKWORKS Massage Chair USER MANUAL...

Страница 2: ...ily for therapeutic massage treatment It is intended to be used by a therapist in a professional environment No special training is required to use this chair The therapist should read and understand...

Страница 3: ...T 2 CAUTION SETTING UP YOUR CHAIR Make sure the cable is fully extended before sitting on the chair 1 Lean your chair forward and lift the back of the seat until fully open 2 Remove the plastic coveri...

Страница 4: ...r than the front Lumbar strain can be reduced by raising the seat height one to two holes To change the seat height Push in button on seat tube while raising or lowering the seat Release button when p...

Страница 5: ...ed the client can put right knee on the right knee pad You can then make the proper adjustments to the face and arm rests for proper client comfort and positioning HELPING YOUR CLIENT ONTO THE CHAIR A...

Страница 6: ...els will roll on any surface To carry your chair lift by holding onto one of the main tubes at the pivot bolt and resting the seat pad against your hip The optional shoulder strap will make carrying y...

Страница 7: ...oses you may use Parker Labs ProtexTM EPA reg 6836 152 82613 Healthlink E Z Kill EPA reg 59894 10 67454 or MADA Medical Madacide FD EPA reg 1130 15 11703 Dry the table immediately after cleaning to re...

Страница 8: ...Revision Date 04 04 2018 English Printed in USA CONTACT INFORMATION O Inc 923 East Wellspring Road New Freedom PA 17349 Phone 717 235 6807 FAX 717 235 6798 www oakworksmed com made in the USA with US...

Отзывы: