background image

12 GAUGE

 INSTRUCTION MANUAL    17

SAFEGUArdiNG

WATER EXPOSuRE

Prior  to  exposing  the  timepiece  to  water,  ensure  both  crowns  are  pushed  fully  down  against  the  case  then  turn 

them clockwise to tighten their water seal. Rated at 10-bar hydrophobic, the timepiece may be worn during bathing, 

swimming and shallow diving. It is not designed for scuba or saturation diving. Do not pull out either crown or use the 

buttons if the timepiece is wet. If used in seawater, rinse the timepiece with fresh water and dry completely.

TEMPERATuRE

For precision timekeeping, normal operating temperature is 0°C to 50°C (32°F to 122°F).

MAGNETISM

Strong magnetic fields can have an adverse effect on the timepiece. Keep it away from magnetic objects.

CHEMICALS

The timepiece may become discolored or damaged if exposed to cosmetic spray, detergents, adhesives, solvents, 

or paints.

SHOCK WAVE

Although the timepiece resists shock damage, impact against a hard surface may cause damage to the movement 

or crystal.

PERIODIC MAINTENANCE

To ensure that the case, crowns, crystal seal, and gasket remain resistant to water exposure, it is recommended that 

the timepiece be inspected once every 2 to 3 years by an Authorized Oakley Service Center.

Содержание 12 GAUGE

Страница 1: ......

Страница 2: ......

Страница 3: ...TABLE OF CONTENTS ENGLISH 1 08 ESPAÑOL 00 00 FRANCAIS 00 00 ITALIANO 00 00 Português 00 00 Magyar 00 00 DEUTSCH 00 00 JAPANESE 00 00 2009 Oakley Inc U S Patent s Pending ...

Страница 4: ......

Страница 5: ... rubber strap SETTING THE DATE AND TIME Your Oakley timepiece has two crowns and both are made with a screw down design that provides added protection against moisture The main crown 3 o clock position can be pulled out to two click positions for setting the date and time To set the date and time the first time or to reset the date and time after the battery is changed do the following 1 Unscrew t...

Страница 6: ...ings from 01 to 31 when performing the instructions above IMPORTANT The alarm has its own timekeeping mechanism Whenever the time on the main display is adjusted it is necessary to adjust this separate mechanism to keep the alarm synchronized Do the following TO SYNCHRONIZE THE ALARM 1 Pull the main crown out to the second click position b 2 Press and hold button B for at least 2 seconds The minut...

Страница 7: ...E ALARM ON OFF Briefly press button B Two beeps indicate the alarm is switched on One beep indicates the alarm is switched off USING THE ALARM The lower sub dial shows the alarm time The alarm can be set a maximum of 12 hours before the desired alarm time When the alarm time is reached a sound is emitted for 20 seconds If the alarm button is not pressed this sound is repeated after two minutes Not...

Страница 8: ...e using the chronograph ensure the main crown is fully against the case and not at one of the click positions used for setting time and date The three chronograph hands should align precisely at the zero position If they do not see the section Adjusting the Chronograph Hands TO MEASURE ADDED TIME Added time cumulative time is a measure of how much time has passed without including pauses This feat...

Страница 9: ...iming Press button B to pause the chronograph hands and read the current time total Although the hands are no longer moving time is still being measured Press button B again to move the hands to the currently running time total Continue to use button B to pause the hands when desired Time continues to be measured Stop timing and display the final time total While the hands are moving press button ...

Страница 10: ...ner ring scale of the bezel is aligned with the minute hand 3 Push the crown back in Gently turn the crown clockwise until it screws back into the case Be careful not to over tighten the crown as this will damage the mechanism During the countdown time interval read the remaining time by seeing where the minute hand points on the inner ring scale of the bezel When the minute hand reaches the zero ...

Страница 11: ...ase Be careful not to over tighten the crown as this will damage the mechanism You are now ready to compute speed based on travel time Speed can be measured in miles per hour kilometers per hour or another unit of measure per hour Only speeds above 60 can be measured To compute speed do the following Start timing at a marker When you reach a distance marker such as a mile or kilometer marker press...

Страница 12: ...n A to stop the hands 2 Unscrew the main crown from the case Pull the crown out to the second click position b 3 Push button A and button B simultaneously and keep them pressed for at least 2 seconds 4 Adjust the chronograph hands by doing the following Press button A to adjust the chronograph hand that counts seconds Press and hold the button for continuous movement Press button B to finish with ...

Страница 13: ...nsive performance checks its actual life once in your possession may be less Battery replacement may be performed only by an Authorized Oakley Service Center Any attempt to open the watch case by persons other than Authorized Oakley Service Professionals will void the product warranty Within the United States call Oakley global headquarters at 1 800 403 7449 to find an Authorized Oakley Timepiece ...

Страница 14: ...n the band by removing links yourself as this may result in damage to the bracelet Rubber Strap Model The strap adjustment should be done by an Authorized Oakley Timepiece Dealer Do not attempt to shorten the rubber strap yourself as this may result in damage CLEANING Failure to keep the case and band clean may result in a skin rash Use a soft clean cloth to wipe off any moisture that adheres to t...

Страница 15: ...achined CRYSTAL Sapphire with anti reflective coating CROWNS Screw down design for water resistance Stainless Steel Bracelet Model BRACELET COMPOSITION Stainless steel and Carbon Fiber CLOSURE Stainless steel deployment clasp Unobtainium Rubber Strap Model STRAP COMPOSITION Oakley Unobtainium rubber ATTACHMENT Stainless steel attachment link CLOSURE Stainless steel deployment clasp ...

Страница 16: ...SCILLATOR Quartz tuning fork FREQUENCY OF OSCILLATOR 32 768 cycles per sec ACCURACY 10 20 sec per mo THERMAL OPERATING MIN 0ºC 32ºF THERMAL OPERATING MAX 50ºC 122ºF WATER RESISTANCE 10 bar equivalent to depth of 100m 330ft BATTERY Silver oxide No 395 BATTERY ENDURANCE Approx 48 months ...

Страница 17: ...completely TEMPERATURE For precision timekeeping normal operating temperature is 0 C to 50 C 32 F to 122 F MAGNETISM Strong magnetic fields can have an adverse effect on the timepiece Keep it away from magnetic objects CHEMICALS The timepiece may become discolored or damaged if exposed to cosmetic spray detergents adhesives solvents or paints SHOCK WAVE Although the timepiece resists shock damage ...

Страница 18: ...servicing done by agents other than Authorized Oakley Service Facilities This warranty does not affect specific legal rights of the consumer To qualify for service under the above guarantee valid proof of purchase which clearly shows the purchase date and the name of the Authorized Oakley Timepiece Dealer must be presented if a repair claim is made during the warranty period REGISTRATION The cutti...

Страница 19: ...kley Africa 27 41 501 0200 Oakley Brasil Ltda 0800 770 7822 ou 0xx11 4197 9999 Grande São Paulo e celular Oakley Canada 1 877 625 5396 Oakley Europe 44 1462 475 400 Oakley Japan 0120 009 146 Oakley México 52 55 59503643 Oakley South Pacific Australia 1 800 637 001 Oakley South Pacific New Zealand 0800 696 255 ...

Отзывы: