O3zone Generator Kit Instructions
10
Maintenance Instructions
2. Adjust the Potentiometer
If the recorded amperage or voltage is outside of normal levels, the potentiometer may
need to be adjusted. This dial is accessible on the back of the ozone generator unit once
removed from its enclosure and can be adjusted using a screwdriver. To access and adjust,
follow the steps below.
step 1:
Remove the cover of the ozone
generator enclosure.
step 2:
Locate the Potentiometer on the
back of the generator internals.
step 3:
Using a screwdriver, turn the
potentiometer dial fully clockwise. The
potentiometer dial controls the amount of
amperage being supplied from the board
to the generator. Turning it fully clockwise
will supply the lowest amperage to the
generator.
step 4:
On the controller, press and
hold the REGEN button until a manual
regeneration is initiated. Press the regen
button to cycle through regeneration
steps until the Regenerant Draw Down
(Air-Draw) step is reached.
TIME OF DAY
MON
GPM
2:40
8
PM
BACKWASH
10:00
REGENERANT DRAW DN
60:00
Press and Hold Until
Regeneration Starts
Press to Move Through
Regeneration Cycles
step 5:
Wait on the Regenerant Draw
Down Screen for ten seconds. Press and
hold the Up and Down buttons for three
seconds to reach the ozone generator live-
view screen.
REGENERANT DRAW DN
59:50
mA
VDC
GENERATOR
260 12.0