Pre-Installation & Preparation Guidelines

If the Outdoor Fire Pit is connected to a fixed piping gas supply line, the supply line is required to have an on/off gas valve 
installed before the fire pit and it must be closed during any pressure testing of the system at test pressures in excess of ½ 
psi (3.5kPa).  

G.

H.

DO NOT USE IF GAS PRESSURE IS LOWER THAN THE MINIMUM REQUIREMENT OR EXCEEDS THE MAXIMUM.

J.

Note:  The Use Of A Third Party Fire Pit Top, Media and or Components Will Void the Omni Certification
and O.W Lee Warranty. 

GAS SUPPLY PLUMBING REQUIREMENTS 

Apply only joint compounds that are resistant to all gasses on all male pipe fittings.  Make sure to tighten every joint securely.  

DO NOT use pipe joint compound to connect flare fittings

.

INSTALLER NOTE:  This unit should be installed so that it can be removed at a later date for service.

K.

Propane Regulator Hose 

(when used):   The propane regulator hose is located inside the fire pit door panel.  When 

installed, make sure the hose is secured inside the unit and 

DOES NOT TOUCH THE BURNER PAN.

L.

Propane Regulator Hose:

  Always inspect the condition of the propane regulator hose before each operation.  Any signs of 

excessive abrasion the hose MUST BE REPLACED.  Contact your local dealer for replacement part #COM0589

If the Outdoor Fire Pit is connected to a fixed piping gas supply line, the supply line is required to have an on/off gas valve 
installed before the fire pit must be closed during any pressure testing of the system at test pressures equal to or less than ½ 
psi (3.5kPa).

I.

A. Before installing the Outdoor Fire Pit, check “Minimum Clearance to Combustibles” on page 2.

MINIMUM CLEARANCES

 must be maintained when you install this Outdoor Fire Pit.  

THERE  MUST

BE AT LEAST 60”

 (1.5 m) from the center of the burner to any combustible sidewall, ceiling, or material.  

The Outdoor Fire Pit is for outdoor use only.  DO NOT install or use this appliance inside a building,
garage, or any other enclosed area or structure including recreational vehicles, boats & sheds.  

This unit must be

installed in such a manner that proper air ventilation is maintained without obstruction at all times, and during all 
weather conditions. 

B.

C.

CHECK GAS TYPE

 (Natural Gas or Propane):  The gas supply you intend to use may not be the same that your fire pit was 

setup for or is stated on your outdoor rating plate.  

THIS FIRE PIT IS CONSTRUCTED FOR USE WITH PROPANE

 

GAS

.  If 

the gas supply is different, 

or you wish to change to Natural Gas, you MUST have the Fire Pit Converted (directions to 

convert can be found on page 12) to the gas type you intend to use.  Any gas type conversion should be performed 
by a qualified, professional technician or licensed plumber

.  If you are unsure, contact your dealer for assistance.

Page 3

SAFETY NOTE:  An secondary on/off valve, kept in the Off Position, in a fixed piping gas supply line before the fire pit 
is required for safety when your Outdoor Fire Pit is not in use.  It also provides for convenient maintenance and 
repair.

O.

D.

E.

Casual Fireside Fire Pits are suitable for installation from 0 - 4,500 ft. elevation without modification.

M.

F. Fixed Gas piping system must be sized to provide minimum inlet pressure at the maximum flow rate (BTU/hr).  Undue 

pressure loss will occur if the pipe is too small or the run is too long.

GAS PRESSURE REQUIREMENTS:
FOR NATURAL GAS: 

 The minimum inlet gas supply pressure for purposes of input adjustment is 

3.5 inches

 (88.9 mm) 

water column and maximum inlet gas supply pressure is 

10.5 inches

 (266.7 mm) water column.

FOR PROPANE: 

 The minimum inlet gas supply pressure for purposes of input adjustment is 

8 inches

(203 mm) water column and the maximum inlet gas supply pressure is 

13 inches

 (330 mm) water column.

MANIFOLD PRESSURE REQUIREMENT:

   Liquid Propane 9.5 (241.3mm)  / Natural Gas 2.5 (63.5mm) of pressure.

DO NOT INSTALL THIS UNIT IF MINIMUM PRESSURE IS NOT AVAILABLE OR IF MAXIMUM PRESSURE IS 

Содержание CASUAL FIRESIDE 51-09

Страница 1: ...ge and Handling Code B149 2 as applicable The link below will take you to the Owners Manual and Operating Instructions in French where you can download a copy Sélectionnez le lien ci dessous pour télécharger les instructions françaises Tested Certified to ANSI Z21 97 2014 CSA 2 41 2014 CGA 2 17 M91 R2014 APPLIANCE BTU RATING 47 500 Propane 56 000 Natural Gas CASUAL FIRESIDE Model Modèle DANGER Thi...

Страница 2: ...PIT CAN CAUSE SERIOUS INJURY OR DEATH FROM FIRE BURNS EXPLOSIONS OR CARBON MONOXIDE POISONING Clearances to Combustible Construction Sidewalls 60 1 5 m from center of unit Figure 1 Ceiling 60 1 5 m from top of unit to ceiling or overhang Flooring 0 Can be installed on deck slab floor etc The dimensions shown in Figure 1 are MINIMUM CLEARANCES to maintain when you install this Outdoor Fire Pit THER...

Страница 3: ...utdoor Fire Pit is for outdoor use only DO NOT install or use this appliance inside a building garage or any other enclosed area or structure including recreational vehicles boats sheds This unit must be installed in such a manner that proper air ventilation is maintained without obstruction at all times and during all weather conditions B C CHECK GAS TYPE Natural Gas or Propane The gas supply you...

Страница 4: ... the fire pit top surrounding the flame and should stay away to avoid burns and clothing or long hair ignition DO NOT continue using your FIRE PIT if you smell any unusual odors or have headaches nausea or dizziness G WARNING DO NOT throw trash paper plastics or any other flammable materials into your Fire Pit WARNING DO NOT leave in operation when unattended H DO NOT use this appliance if any par...

Страница 5: ... gas at the supply LP Gas Cylinder Valve The LP Gas Cylinder must be disconnected when the appliance is not in use 4 5 6 The LP Gas Cylinder must be standing on the designed bottom base of the cylinder for proper vapor withdrawal CONNECTING AN LP GAS CYLINDER PROPANE TANK TO THE FIRE PIT Page 5 B Minimum Clearance to Combustibles Page 2 IMPORTANT BEFORE PROCEEDING CAREFULLY READ ALL OF THE IMPORTA...

Страница 6: ...ISTANT GLOVES OR ALLOW MATERIAL ADEQUATE TIME TO COOL BEFORE HANDLING Note Lava granules used in a fire pit when heated up to normal operating temperatures can cause trapped gasses or moisture in the porous stone to expand and cause a pop and launch outside of the fire pit which could cause damage or injury Caution should be exercised when heating up the fire pit with lava granules to normal opera...

Страница 7: ...res Figure 3 Pour the second bag of media onto the burner support Taper from the top of the burner towards the width edge Figure 1 Rectangle Burner Support and Stainless Steel Burner Figure 2 Pour the first bag of the glass media into the burner support Page 7 GEM MIRRIORED AND TUMBLED GLASS MEDIA PLACEMENT GEM MIRRIORED AND TUMBLED GLASS MEDIA PLACEMENT Carefully inspect the carton for shipping d...

Страница 8: ...sed in a fire pit when heated up to normal operating temperatures can cause trapped gasses or moisture in the porous stone to expand and may pop and launch outside of the fire pit which could cause damage or injury Caution should be exercised when heating up the fire pit with lava granules to normal operating temperatures Ceramic Rock Placement See Figure 1 2 and 3 Figure 1 Pour the lava granules ...

Страница 9: ... on Converting Your Fire Pit to a Different Gas Type on how to access the venturi the orifice Insert a small wire in the venturi orifice holes to clear passage free of spider webs or other debris Make sure to put everything back correctly when finished for proper fire pit operation and safety This is a common problem when the fire pit has not been used for an extended period of time Low or Excessi...

Страница 10: ...ructions Fire Pit Component Parts O W Lee extends a two 2 year limited warranty on all burner components under normal use and proper maintenance OW Lee will at factory option repair or replace any outdoor fire pit burner found to be defective during this warranty period Regular maintenance must be exercised as set forth in the owner s manual For more information go to www owlee com Items Not Cover...

Страница 11: ...ied professional service technician Force or attempted repair may result in fire or explosion DO NOT use this appliance if any part has been under water Immediately call a qualified professional service technician to inspect the Outdoor Fire Pit and to replace any part of the control system and any gas control that has been under water Push in the manual gas control knob slightly and turn clockwis...

Страница 12: ...move the orifice from the holder Figure 2 and replace it with the proper sized one for your gas requirement Propane requires the smaller orifice 4 If you are converting from propane LP gas to natural gas install the air shutter sleeve so that the air intake holes are closed Figure 2 For Propane gas remove the air shutter so that the air intake holes are open Figure 1 After the unit is assembled fo...

Страница 13: ... inflammables près de cet appareil ou de tout autre appareil ménager Une bouteille basse pression non raccordée pour son emploi ne doit pas être rangée à proximité 1576mm 60 po de cet appareil ou de tout autre appareil ménager ATTENTION L installation le réglage la modification l entretien ou la maintenance incorrects peuvent entraîner des blessures ou dommages matériels Lire attentivement les ins...

Страница 14: ...TRUCTION POUR DETERMINER SI LE FOYER EXTÉRIEUR EN ADMET VOTRE LOCALITÉ AVANT L INSTALLATION POUR USAGE EXTÉRIEUR SEULEMENT CET APPAREIL DOIT ÊTRE INSTALLÉ AU MOINS 60 DE CENTRE DE BRÛLEUR À TOUT COMBUSTIBLE MURS PLAFONDS OU MATERIEL QUAND COUPER L UNITÉ METTEZ LA COMMANDE DE SOUPAPE SUR LE PIT INCENDIE À LA POSITION ENTIÈREMENT A L PIT FIRE ET FERMER LA ABANNE SUR LE RÈSERVIOR DE PROPANE ou GAZ NA...

Страница 15: ... LA PRESSION MAXIMALE EST DÉPASSÉE F Le système de tuyauterie du gaz doit être dimensionné de sorte à fournir la pression minimale d admission au débit maximum BTU hr Une perte excessive de pression se produira si le tuyau est trop petit ou trop long G Casual Fireside foyers sont adaptés pour l installation à partir de 0 4500 m sans modification H Si le foyer extérieur est raccordé au gaz naturel ...

Страница 16: ...é au besoin afin de maintenir le fonctionnement et la flamme correcte en toute sécurité la hauteur et la coloration Page 4 L M Q P Le brûleur doit être remplacé avant de l appareil étant mis en service s il est évident que le brûleur est endommagé Remplacement brûleur COM0580 fabriqué par O W Lee Company 1822 E Francis Street Ontario CA 91761 R S INFORMATIONS IMPORTANTES SUR LA SÉCURITÉ A B E J AV...

Страница 17: ...Le LP cylindre de gaz à utiliser doit être muni d un dispositif de prévention de remplissage excessif OPD et avec un dispositif de raccordement compatible avec la connexion de l appareil 2 LA BOUTEILLE LP GAS Réservoir de propane INFORMATION Allumez le gaz vers le système de brûleur et d essai pour les fuites avec une solution d eau savonneuse Ne jamais utiliser une flamme nue pour les tests Si un...

Страница 18: ...ranules de lave nº 13 Granules de lave 9 mm 3 8 po nº 14 Caillou de Feu en Verre Fourbi Taille 3 3 4 1 2 9 19 mm nº 15 Miroir en verre Taille 1 4 6 35 mm POSE DES GRANULES DE LAVE ET DES CRISTAUX DE VERRE Verser le sac de granules de lave ou de cristaux de verre dans le foyer extérieur de sorte que le brûleur soit totalement recouvert Voir la liste des pièces ci dessus pour les articles approuvés ...

Страница 19: ...yau de verre dégringolé médias de verre dans le Brasier extérieur de sorte que le brûleur est complètement recouverte Voir la Figure 1 2 et 3 Figure 1 Rectangle brûleur de soutien et En acier inoxydable Burner Figure 2 Verser le premier sac du support de verre dans le support de brûleur Figure 3 Verser le deuxième sac de médias sur le support de brûleur Taper du haut du brûleur vers le bord de lar...

Страница 20: ...RE placement dans les médias Rocher Placement céramique Voir la Figure 1 2 et 3 ATTENTION brûlures ROCK CÉRAMIQUE ET CHAMP MEDIA Restera chaud pendant un certain temps après l utilisation VOUS DEVEZ conserver la disposition comme indiqué pour assurer le bon fonctionnement de votre feu PIT SI VOUS nécessité de repositionner TOUT MATÉRIEL POUR MAINTENIR l aménagement utiliser la chaleur GANTS résist...

Страница 21: ...et l orifice Insérez un petit fil dans le venturi et orifices des trous pour dégager le passage libre des toiles d araignées ou d autres débris Assurez vous de tout remettre correctement lorsque vous avez terminé pour le fonctionnement du foyer adéquat et la sécurité Ceci est un problème commun lorsque le foyer n a pas été utilisé pendant une longue période de temps Flamme faible ou excessive Util...

Страница 22: ... Parties Pit Fire O W Lee offre une garantie limitée de deux 2 ans sur tous les composants du brûleur en utilisation normale et appropriée entretien OW Lee sera à l usine de réparer ou de remplacer tout brûleur extérieur foyer trouvé défectueux pendant cette période de garantie Un entretien régulier doit être exercé selon dans le manuel du propriétaire Pour plus d informations consultez www owlee ...

Страница 23: ... l emploi du foyer une fois installé voir les figures ci dessous pour les positions typiques du contrôle POUR VOTRE SÉCURITÉ LIRE AVANT D ALLUMER ATTENTION L INOBSERVATION DE CES INSTRUCTIONS À LA LETTRE POURRAIT ÊTRE LA CAUSE D UN INCENDIE OU D UNE EXPLOSITION ENTRAÎNANT DES DOMMAGES MATÉRIELS DES BLESSURES OU LA MORT AVANT DE FAIRE FONCTIONNER sentez autour de la zone foyer extérieur pour le gaz...

Страница 24: ...T NÉCESSAIRE DE POSER L ÉTIQUETTE OU LA PLAQUE SIGNALÉTIQUE INCLUSE DANS LE KIT DE CONVERSION AFIN D INDIQUER CLAIREMENT LA CONVERSION FAITE SUR PLACE FIGURE 1 FIGURE 2 RÉSERVÉ AU FABRICANT Contrôle de la qualité Suivez les étapes 1 5 ci dessus LA CONVERSION SERA EFFECTUÉE PAR UN REPRÉSENTANT AGRÉÉ DU FABRICANT CONFORMÉMENT AUX EXIGENCES DU FABRICANT DES POUVOIRS PROVINCIAUX OU TERRITORIAUX AYANT ...

Отзывы: