Alternative settings
Jumper 1 closed
Insertion of two coins available
Jumper 2 closed
Upper Dip for setting of seconds
Lower Dip for setting of minutes
Value of Dip-switch:
1 – 2 – 4 – 8 – 16 – 32
Notice
To secure the activation of basic-settings and time-settings, it is essentisal to cut the
device from power shortly. On first usage, the LED will flash four digits followed by
a break. The combination of digits indicates the installed software. The permanent
display of the digit „0“ indicates the ready-status.
2.2 time setting
To set the running time, the imprinted values of DIP-switches set to „on“ position has
to be added.
E.G.
Upper-DIP-switch
switch 1, 3 and 4 set to „on“
The result of addition of imprinted values is 13
In addiction of basic setting, the running time is set to 13 minutes or 13 seconds.
Lower-DIP-switch
switch 2 and 5 set to „on“
The result of addition of imprinted values is 18
In addition with the values of the upper-DIP-switch the total running time is 18 minu-
tes and 13 seconds or 18 hours and 13 minutes.
2.3 Display
After insertion of first coin a „1“ is displayed. After insertion of a second coin (if acti
-
vated) a „2“ is displayed. The display will jump back to „1“ if the time stock of second
coin is used up. When time stock reaches the last 9 minutes the remaining time
flashes on display in one minute steps. If the running time per coin is set to a lower
value than 9 minutes, this time will flash on display.
3. Special features ZMZ 0205
3.1 Coin register (Option „A“)
When ordering „Option A“ a mechanical 5-/6-digit non-resetable roller counter is
mounted on the cover for registration of all inserted coins. This option is retrofittable
by factory easily.