SAFETY INSTRUCTIONS

• 

Read the instructions carefully and fully prior to putting 
the aquarium into operation and store it in a safe place.

• 

When using electrical equipment in or in close proximity 
to the aquarium, observe the instructions of the respec-
tive manufacturer.

• 

With all electrical equipment, the cable must form a drip 
loop so that no water is able to flow along the cable in 
the direction of the socket. The drip loop must be positi-
oned above the respective water level (Fig. 1).

• 

This product is approved exclusively for use indoors and 
only for aquarium applications.

• 

Do not move the aquarium when filled, or attempt to lift it. 

• 

Even when the aquarium is empty, never lift it by the 
overflow box.

• 

Before putting hands in the water, disconnect all electri-
cal equipment from the power supply.

• 

This product is not intended for use by persons (including 
children) with limited physical, sensory or mental capabi-
lities, unless they are supervised by a person responsible 
for their safety, or have received instruction from such 
a person on how to use the product. Children must be 
supervised to ensure they do not play with the product.

5

EN

Содержание OPUS 300

Страница 1: ...OPUS 300 INSTRUCTIONS...

Страница 2: ...2 VIDEO INSTRUCTIONS AQUARIUM ASSEMBLY VIDEO INSTRUCTIONS EQUIPMENT INSTALLATION VIDEO INSTRUCTIONS STARTING THE TANK VIDEO INSTRUCTIONS ADDING LIVE STOCK...

Страница 3: ...quarium Before putting the product into operation please read the instructions carefully CONTENTS SAFETY INSTRUCTIONS 4 ASSEMBLY 6 FUNCTIONALITY AND EQUIPMENT REQUIRED 17 STARTING THE TANK 20 MAINTENA...

Страница 4: ...SAFETY INSTRUCTIONS 4 Fig 1...

Страница 5: ...water level Fig 1 This product is approved exclusively for use indoors and only for aquarium applications Do not move the aquarium when filled or attempt to lift it Even when the aquarium is empty nev...

Страница 6: ...s STEP 1 SELECTION OF THE INSTALLATION SITE The floor on which the OPUS 300 is installed must be level The floor on which the OPUS 300 is installed must be sufficiently load bearing The OPUS 300 has a...

Страница 7: ...he wall For reasons of accessibility the OPUS 300 should exhi bit a distance of approx 60 cm 24 in from neighbouring walls or furniture on both the right and left side Make sure the floor covering aro...

Страница 8: ...ium out of the cabinet with the help of a second person When doing so make sure the aquarium remains straight and level when lifted out to avoid damage to the cabinet Set the aquarium down on the prep...

Страница 9: ...of at least one further person Align the aquarium cent rally so that the gap between the cabinet and aquarium is evenly sized on all sides No underlay is required between the aquarium and the cabinet...

Страница 10: ...P The transparent acrylic panel with the two PVC threaded connections is fastened at the rear right on the sump with the two transparent plastic screws Fig 2 Install the filter sock in the sump at the...

Страница 11: ...hen screw tight in the overflow box hand tight do not over wind tool is not required The pipe with the largest diameter sits in the middle the two narrower pipes are identical and are fitted adjacent...

Страница 12: ...elongs in the left chamber of the sump return chamber We recommend that the Auto Top Off system be installed only after the aquarium has been filled with seawater see page 22 step 4 The cover panels c...

Страница 13: ...ASSEMBLY STEP 7 INSTALLING THE PUMP OUTLET An outlet port is located in the overflow box for the pump outlet This can be simply fitted on the pump outlet in the aquarium 13 EN...

Страница 14: ...and the screws provided part number 29 Fig 8 Now attach the doors with hinges to the cabinet using the pre drilled holes and the screws provided part num ber 29 A second person should hold the doors F...

Страница 15: ...ALLING THE CABINET LIGHTING The LED lighting can be fastened in the cabinet at the top right or top left see sketch Before fastening check that it switches on when the door is opened and off when the...

Страница 16: ...arium and cabinet Start on the rear side of the aquarium roughly in the centre beneath the overflow box Fit the silicone cord with a little excess material at the corners of the aquarium so that the c...

Страница 17: ...inimum SUMP 1 A bubble trap is located in the right rear chamber of the sump 2 The water subsequently flows via a filter sock which filters dirt particles out of the water 3 At the front right in the...

Страница 18: ...6 In the chamber far left the water is fed back into the display tank via the return pump Because the water level in the return chamber varies compensation for the water lost through evaporation takes...

Страница 19: ...options for successfully operating a reef aquarium The following components are recommended on the basis of our experience INFORMATION ON THE RETURN PUMP The maximum pump capacity of the Nyos OPUS 300...

Страница 20: ...components skimmer return pump etc are installed in compliance with the manufacturer s safety instructions The Auto Top Off system is only required once the aqua rium is in operation We therefore rec...

Страница 21: ...t the valve opens further As soon as you begin to approach to the correct settings the valve should only be turned slightly It takes a few minutes for the water level to adjust to the respective valve...

Страница 22: ...e abo ve the intake of the return pump so that the pump does not draw in air Now connect the Auto Top Off system and the refill tank with the transparent hose provided and set the refill tank on the t...

Страница 23: ...647 part no 21 Note If the filter sock is clogged the water no longer flows through the filter sock but rather over it The func tion of the sump remains intact VALVE The valve can be opened and cleane...

Страница 24: ...mp outlet and the filter comb on the overflow box at regular intervals to remove algae deposits etc Check that no foreign bodies are present inside the out flow and emergency outflow Clean the pipes o...

Страница 25: ...ump DISPLAY TANK When cleaning the panes of the display tank and sump with a scraper make sure the blades do not damage the silicone seams Do not use magnetic cleaners to clean the rear pane of the di...

Страница 26: ...EXPLODED DRAWING 26 6 7 1 2 3 4 5 27 30 31 32 8 9 10 11 12 13 14 15 20 24 25 21 26 22 23 33 27 28 29...

Страница 27: ...on 1 Display tank including complete overflow box 2 OPSP_0432 2 Complete overflow box Body cover pump outlet 3 4 OPSP_0449 3 Overflow box cover OPSP_0456 4 Pump outlet consisting of three components O...

Страница 28: ...P_0494 7 Outflow pipe straight 32 mm for main outflow including seal 17 OPSP_0500 8 Inflow pipe angled 20 mm for return pump including seal 19 OPSP_0517 9 Pipe adapter 20 mm for return pump complete t...

Страница 29: ...tflow angled 32 mm inclu ding seal 12 13 18 OPSP_0548 12 Diaphragm for valve OPSP_0555 13 Screw kit and rubber caps for valve 4 units OPSP_0562 14 Transparent acrylic glass with 2 x PVC pipe and threa...

Страница 30: ...no Illustration 16 Seal for outflow inflow pipe straight 20 mm OPSP_0593 17 Seal for outflow pipe straight 32 mm OPSP_0609 18 Seal for 32 mm threa ded connection OPSP_0616 19 Seal for 20 mm threa ded...

Страница 31: ...des part no Article no Illustration 21 Filter sock OPSP_0647 22 Cover panel sump right OPSP_0654 23 Cover panel sump left OPSP_0661 24 Auto Top Off system without hose OPSP_0678 25 Hose for Auto Top...

Страница 32: ...ustration 26 Refill tank OPSP_0692 27 Cabinet including doors and hinges push knobs 28 29 30 Wei OPSP_0708 Grau OPSP_0715 28 Hinges for cabinet doors 2 units OPSP_0722 29 Screws for hinges 4 units OPS...

Страница 33: ...Part no Part name This part also inclu des part no Article no Illustration 31 Lighting for cabinet OPSP_0753 32 Foot for cabinet 1 unit OPSP_0760 33 Underlay for sump OPSP_0777 PARTS LIST 33 EN...

Страница 34: ...NOTES 34...

Страница 35: ...NOTES 35 EN...

Страница 36: ...www facebook com nyos aquatics Nyos Aquatics GmbH Siemensstr 26 70825 Korntal Muenchingen Germany www nyos info info nyos info...

Отзывы: