Tag scanning
Before you can run a PKE application you have to check the Tags infrastructure. After
click on the
S
S
c
c
a
a
n
n
T
T
a
a
g
g
s
s
button all available Tags in range will be scanned and added to a
list box. By selecting one available Tag from the list you can run different kinds of PKE
applications.
Cyclic Authent
Select one of the available tags. Enabling the
C
C
y
y
c
c
l
l
i
i
c
c
A
A
u
u
t
t
h
h
e
e
n
n
t
t
checkbox performs a cyclic
authentication using the HITAG2 crypto algorithm. The exchanged values will be dis-
played in the appropriate fields. Change the default Secret Key (
I
I
S
S
K
K
) if necessary. Dis-
abling the
C
C
y
y
c
c
l
l
i
i
c
c
A
A
u
u
t
t
h
h
e
e
n
n
t
t
checkbox stops the cyclic authentication. The authentication
values are no longer available.
Single Authent
Select one available Tag from the list. A single authentication can be performed after
each press on the
S
S
i
i
n
n
g
g
l
l
e
e
A
A
u
u
t
t
h
h
e
e
n
n
t
t
button. The exchanged values will be displayed in the
appropriate fields. Change the default Secret Key (
I
I
S
S
K
K
) if necessary.
RSSI
Select one available Tag from the list. Enabling the
C
C
y
y
c
c
l
l
i
i
c
c
R
R
S
S
S
S
I
I
checkbox performs a
cyclic RSSI measurement of all three axes, and calculates the Sum signal as squared
vector length (squared geometric mean) V
2
= X
2
+ Y
2
+ Z
2
. Each single value will dy-
namically be displayed in a separate progress bar. Disabling the
C
C
y
y
c
c
l
l
i
i
c
c
R
R
S
S
S
S
I
I
checkbox
stops the RSSI measurement. The RSSI values are no longer available.
Select different ADC Resolutions for the RSSI measurements using the
A
A
D
D
C
C
R
R
e
e
s
s
o
o
l
l
u
u
t
t
i
i
o
o
n
n
combo box. This setting is only enabled during stopped RSSI measurement.
V
Bat
Select an available Tag from the list. Enabling the
C
C
y
y
c
c
l
l
i
i
c
c
C
C
h
h
e
e
c
c
k
k
checkbox performs a
cyclic measurement of the Tag battery voltage. The Tag battery voltage will be displayed
in the appropriate field. Select different loads for the Tag battery voltage measurement
using the
M
M
e
e
a
a
s
s
u
u
r
r
e
e
m
m
e
e
n
n
t
t
L
L
o
o
a
a
d
d
combo box. This setting can be changed during a running
measurement. Disabling the
C
C
y
y
c
c
l
l
i
i
c
c
C
C
h
h
e
e
c
c
k
k
checkbox stops the Tag battery voltage mea-
surement. The current voltage is no longer available.
PKE Settings
For the PKE authentication change the default Secret Key (
I
I
S
S
K
K
) if necessary.
For the RSSI measurement the default value for the ADC resolution is 12 Bit. Different
ADC resolutions can be set.
For the Tag battery voltage measurement different measurement loads can be set.
6.10 Transponder EEPROM window
The EEPROM window is opened by clicking
E
E
E
E
P
P
R
R
O
O
M
M
…
…
in the immobilizer applet window.
This button is available only if the immobilizer applet is started. Authentication is not re-
quired but without a proper authentication, only limited or even no memory content can
be shown (depending on the security configuration of the transponder).
As soon as the window is opened, the transponder is contacted and all pages which are
currently visible on the screen (in the main area) are read from the transponder. This is
done continuously several times per second until the window is closed or the immobilizer
applet is stopped.