![NXP Semiconductors TED-Kit 2 Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/nxp-semiconductors/ted-kit-2/ted-kit-2_user-manual_1721752036.webp)
NXP Semiconductors
UM10276_1
TED-Kit 2 User Manual
All information provided in this document is subject to legal disclaimers.
© NXP B.V. 2010. All rights reserved.
User manual
Rev. 1.29 — 20 August 2010
36 of 79
Fig 52. Firmware update dialog
It explains that the TED-Kit 2 “My TED-Kit” with serial number A1Q55A99 is running
firmware version 1.13 while the support firmware is version 1.19.
Clicking the
U
U
p
p
d
d
a
a
t
t
e
e
button will start the update procedure which takes 10...15 seconds.
Clicking the
C
C
a
a
n
n
c
c
e
e
l
l
button will not do anything with the TED-Kit 2. To avoid any conflicts
between the GUI and this TED-Kit 2, it is deactivated and cannot be used in the GUI. The
hardware view will show it grayed out.
To reactivate the TED-Kit 2, unplug it from the PC and plug it in again or restart the GUI
and actually update the firmware.
Note: To ensure each TED-Kit 2 runs exactly the firmware which is known by the
GUI, an up- or down(!)grade of the firmware version may take place.
To find the firmware currently supported by the GUI, look in the Firmware folder inside
the installation folder:
[TED-Kit 2 Installation]/Firmware
It contains files with names like 03-001019-r.hex. This is the release [r] firmware version
001.019 (or just 1.19) for main board revision 03 (or just 3).
5.9 Using unsupported hardware
In case of a very old main board together with a very new GUI software (or vice versa), a
hardware support conflict might happen. The reason for that is that an old GUI version is
not certified to work with a newer main board revision or a new GUI does not support an
outdated main board anymore. A dialog like in Fig 53 is shown: